Tracheal intubation in patients with cervical spine immobilization: A comparison of McGrath((R)) video laryngoscope and Truview EVO2((R)) laryngoscope

被引:9
|
作者
Bhola, Ruchi [1 ]
Bhalla, Swaran [1 ]
Gupta, Radha [1 ]
Singh, Ishwar [1 ]
Kumar, Sunil [2 ]
机构
[1] Jaipur Golden Hosp, Dept Anaesthesiol, Rohini, India
[2] Max Hosp, New Delhi, India
关键词
McGrath video laryngoscope; simulated difficult airway; Truview laryngoscope;
D O I
10.4103/0019-5049.135035
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Literature suggests that glottic view is better when using McGrath (R) Video laryngoscope and Truview (R) in comparison with McIntosh blade. The purpose of this study was to evaluate the effectiveness of McGrath Video laryngoscope in comparison with Truview laryngoscope for tracheal intubation in patients with simulated cervical spine injury using manual in-line stabilisation. Methods: This prospective randomised study was undertaken in operation theatre of a tertiary referral centre after approval from the Institutional Review Board. A total of 100 consenting patients presenting for elective surgery requiring tracheal intubation were randomly assigned to undergo intubation using McGrath (R) Video laryngoscope (n = 50) or Truview (R) (n = 50) laryngoscope. In all patients, we applied manual-in-line stabilisation of the cervical spine throughout the airway management. Statistical testing was conducted with the statistical package for the social science system version SPSS 17.0. Demographic data, airway assessment and haemodynamics were compared using the Chi-square test. A P < 0.05 was considered significant. Results: The time to successful intubation was less with McGrath video laryngoscope when compared to Truview (30.02 s vs. 38.72 s). However, there was no significant difference between laryngoscopic views obtained in both groups. The number of second intubation attempts required and incidence of complications were negligible with both devices. Success rate of intubation with both devices was 100%. Intubation with McGrath Video laryngoscope caused lesser alterations in haemodynamics. Conclusions: Both laryngoscopes are reliable in case of simulated cervical spine injury using manual-in-line stabilisation with 100% success rate and good glottic view.
引用
下载
收藏
页码:269 / 274
页数:6
相关论文
共 50 条
  • [21] TRACHEAL INTUBATION USING McGRATH VIDEO LARYNGOSCOPE IN MYASTHENIA GRAVIS PATIENTS
    Manne, Venkata Sesha Sai Krishna
    Marupudi, Madhavi Latha
    Yelavarthy, Surendranath
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (56): : 9780 - 9785
  • [22] Comparison between the Truview PCD™ or the GlideScope® video laryngoscope and direct laryngoscopy for tracheal intubation in pediatric patients
    Kun P. Liu
    Cheng H. Li
    Fu S. Xue
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2013, 60 : 735 - 736
  • [23] Comparison of haemodynamic responses to tracheal intubation using Macintosh and Airtraq (R) laryngoscope in patients with simulated cervical spine injury
    Mathew, Nithin
    Gaude, Yogesh Kanta
    Joseph, Tim Thomas
    Kini, K. Gurudas
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2018, 26 (02): : 124 - 130
  • [24] Comparison between the Truview PCD™ or the GlideScopeA® video laryngoscope and direct laryngoscopy for tracheal intubation in pediatric patients
    Liu, Kun P.
    Li, Cheng H.
    Xue, Fu S.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2013, 60 (07): : 735 - 736
  • [25] A comparison of the ease of tracheal intubation using a McGrath MAC® laryngoscope and a standard Macintosh laryngoscope
    Wallace, C. D.
    Foulds, L. T.
    McLeod, G. A.
    Younger, R. A.
    McGuire, B. E.
    ANAESTHESIA, 2015, 70 (11) : 1281 - 1285
  • [26] Use of the TruView EVO2 laryngoscope in Treacher Collins syndrome after unplanned extubation
    Angel Gomez-Rios, Manuel
    Nieto Serradilla, Laura
    Etxaniz Alvarez, Angel
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (03) : 257 - 258
  • [27] Tracheal intubation using a Macintosh laryngoscope or a GlideScope® in 15 patients with cervical-spine immobilization
    Agrò, F
    Barzoi, G
    Montecchia, F
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) : 705 - 706
  • [28] Training resident anesthesiologists in adult challenging intubation comparing Truview EVO2™ and Macintosh laryngoscope: a preliminary study
    Carlino, C.
    Pastore, J. C.
    Battistini, G. M.
    Cancellieri, F.
    De Caria, D.
    Ruggieri, N.
    Bordone, G.
    Bellato, V.
    MINERVA ANESTESIOLOGICA, 2009, 75 (10) : 563 - 567
  • [29] Airway Management with Cervical Spine Immobilisation: A Comparison between the Macintosh Laryngoscope, Truview Evo2, and Totaltrack VLM Used by Novices-A Manikin Study
    Aleksandrowicz, Dawid
    Gaszynski, Tomasz
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [30] Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial
    Łukasz Szarpak
    Łukasz Czyżewski
    Andrzej Kurowski
    Zenon Truszewski
    European Journal of Pediatrics, 2015, 174 : 1325 - 1332