Tracheal intubation in patients with cervical spine immobilization: A comparison of McGrath((R)) video laryngoscope and Truview EVO2((R)) laryngoscope

被引:9
|
作者
Bhola, Ruchi [1 ]
Bhalla, Swaran [1 ]
Gupta, Radha [1 ]
Singh, Ishwar [1 ]
Kumar, Sunil [2 ]
机构
[1] Jaipur Golden Hosp, Dept Anaesthesiol, Rohini, India
[2] Max Hosp, New Delhi, India
关键词
McGrath video laryngoscope; simulated difficult airway; Truview laryngoscope;
D O I
10.4103/0019-5049.135035
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Literature suggests that glottic view is better when using McGrath (R) Video laryngoscope and Truview (R) in comparison with McIntosh blade. The purpose of this study was to evaluate the effectiveness of McGrath Video laryngoscope in comparison with Truview laryngoscope for tracheal intubation in patients with simulated cervical spine injury using manual in-line stabilisation. Methods: This prospective randomised study was undertaken in operation theatre of a tertiary referral centre after approval from the Institutional Review Board. A total of 100 consenting patients presenting for elective surgery requiring tracheal intubation were randomly assigned to undergo intubation using McGrath (R) Video laryngoscope (n = 50) or Truview (R) (n = 50) laryngoscope. In all patients, we applied manual-in-line stabilisation of the cervical spine throughout the airway management. Statistical testing was conducted with the statistical package for the social science system version SPSS 17.0. Demographic data, airway assessment and haemodynamics were compared using the Chi-square test. A P < 0.05 was considered significant. Results: The time to successful intubation was less with McGrath video laryngoscope when compared to Truview (30.02 s vs. 38.72 s). However, there was no significant difference between laryngoscopic views obtained in both groups. The number of second intubation attempts required and incidence of complications were negligible with both devices. Success rate of intubation with both devices was 100%. Intubation with McGrath Video laryngoscope caused lesser alterations in haemodynamics. Conclusions: Both laryngoscopes are reliable in case of simulated cervical spine injury using manual-in-line stabilisation with 100% success rate and good glottic view.
引用
下载
收藏
页码:269 / 274
页数:6
相关论文
共 50 条
  • [1] Evaluation of Truview evo2 (R) Laryngoscope In Anticipated Difficult Intubation - A Comparison To Macintosh Laryngoscope
    Singh, Ishwar
    Khaund, Abhijit
    Gupta, Abhishek
    INDIAN JOURNAL OF ANAESTHESIA, 2009, 53 (02) : 164 - 168
  • [2] Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilization
    Malik, M. A.
    Maharaj, C. H.
    Harte, B. H.
    Laffey, J. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (05) : 723 - 730
  • [3] ALTERNATIVE IN DIFFICULT INTUBATION: VIDEO-LARYNGOSCOPE TRUVIEW EVO2
    Redondo, F. J.
    Madrazo, M.
    Bosque, A.
    Pretel, M.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (03): : 196 - 196
  • [4] An evaluation of the TruView EVO2 laryngoscope
    Li, J. B.
    Xiong, Y. C.
    Wang, X. L.
    Fan, X. H.
    Li, Y.
    Xu, H.
    Ma, Y.
    Deng, X. M.
    ANAESTHESIA, 2007, 62 (09) : 940 - 943
  • [5] Evaluation of the Truview (TM) EVO2 laryngoscope for nasotracheal intubation
    Raveendra, U. S.
    Mehandale, Sripada G.
    Shetty, Sumalatha R.
    Kamath, Manjunath R.
    SAUDI JOURNAL OF ANAESTHESIA, 2012, 6 (04) : 398 - 402
  • [6] Comparison of TruView EVO2 with Miller laryngoscope in paediatric patients
    Inal, Mehmet Turan
    Memis, Dilek
    Kargi, Murat
    Oktay, Zumral
    Sut, Necdet
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (11) : 950 - 954
  • [7] A comparison of the TruView EVO2 and macintosh laryngoscope blades
    Tutuncu, Ayse Cigdem
    Kaya, Guner
    Tunali, Yusuf
    Altintas, Fatis
    Dilmen, Ozlem Korkmaz
    CLINICS, 2011, 66 (04) : 709 - 711
  • [8] COMPARISON OF TRUVIEW EVO2 LARYNGOSCOPE WITH MACINTOSH LARYNGOSCOPE ON PATIENTS UNDERGOING CAESAREAN SECTION
    Inal, Mehmet Turan
    Memis, Dilek
    Yandim, Tarik
    Ersoz, Sule
    NOBEL MEDICUS, 2016, 12 (03): : 12 - 16
  • [9] Evaluation of new laryngoscope blade for tracheal intubation, Truview EVO2©:: a manikin study
    Miceli, L.
    Cecconi, M.
    Tripi, G.
    Zauli, M.
    Della Rocca, G.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (06) : 446 - 449
  • [10] A COMPARISON OF THE EFFICACY OF MACINTOSH LARYNGOSCOPE, TRUVIEW EVO2 AND MCGRATH VIDEOLARYNGOSCOPY IN PAEDIATRIC CASES.
    Cakirca, M.
    Bektas, M.
    Demir, A.
    Basar, H.
    Baltaci, B.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 679 - 679