2-STAGE INVERSION-RECOVERY EXPERIMENTS FOR MEASUREMENTS OF T1

被引:7
|
作者
TAITELBAUM, H
FERRETTI, JA
SPENCER, RGS
WEISS, GH
机构
[1] NHLBI,BIOPHYS CHEM LAB,BETHESDA,MD 20892
[2] NIA,CELLULAR & MOLEC BIOL LAB,BALTIMORE,MD 21224
[3] UNIV MARYLAND,INST PHYS SCI & TECHNOL,COLL PK,MD 20742
关键词
D O I
10.1006/jmra.1993.1248
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A theory for the optimal design of experiments for measuring values of T1 using a two-stage design is developed. It is shown that a useful strategy in such designs is to make a preliminary rough estimate of T1 and use the second stage to produce a refinement of the preliminary results. When the initial uncertainty interval for T1 is large, the two-stage design produces results much less sensitive to the value of the true T1 than those obtainable from a single-stage design. This leads to a significant improvement in the precision of estimates of T1, and in circumstances that depend on the value of T1 estimated in the first stage of the experiment, to a considerable saving in spectrometer time. © 1993 by Academic Press, Inc.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [41] Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values
    Saunders, Adam M.
    Kim, Michael E.
    Gao, Chenyu
    Remedios, Lucas W.
    Krishnan, Aravind R.
    Schilling, Kurt G.
    O'Grady, Kristin P.
    Smith, Seth A.
    Landman, Bennett A.
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [42] Model-based reconstruction for simultaneous multi-slice T1 mapping using single-shot inversion-recovery radial FLASH
    Wang, Xiaoqing
    Rosenzweig, Sebastian
    Scholand, Nick
    Holme, H. Christian M.
    Uecker, Martin
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1258 - 1271
  • [43] 2D APPROACH TO QUANTITATION OF INVERSION-RECOVERY DATA
    VANORMONDT, D
    DEBEER, R
    MARIEN, AJH
    DENHOLLANDER, JA
    LUYTEN, PR
    VERMEULEN, JWAH
    JOURNAL OF MAGNETIC RESONANCE, 1990, 88 (03): : 652 - 659
  • [44] T1 mapping of myocardium using inversion recovery cine at 3.0T
    Yanjie Zhu
    Yinzhu Gao
    Yiu-Cho Chung
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [45] Free-breathing myocardial T1 mapping using inversion-recovery radial FLASH and motion-resolved model-based reconstruction
    Wang, Xiaoqing
    Rosenzweig, Sebastian
    Roeloffs, Volkert
    Blumenthal, Moritz
    Scholand, Nick
    Tan, Zhengguo
    Holme, H. Christian M.
    Unterberg-Buchwald, Christina
    Hinkel, Rabea
    Uecker, Martin
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1368 - 1384
  • [46] Accurate T1 Mapping for Oxygen-Enhanced MRI in the Mouse Lung Using a Segmented Inversion-Recovery Ultrashort Echo-Time Sequence
    Zurek, M.
    Johansson, E.
    Risse, F.
    Alamidi, D.
    Olsson, L. E.
    Hockings, P. D.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2180 - 2185
  • [47] Comparison of 3D Phase-Sensitive, Inversion-Recovery and 2D Inversion-Recovery MRI at 3.0 T for the Assessment of Late Gadolinium Enhancement in Patients with Hypertrophic Cardiomyopathy
    Morita, Kosuke
    Utsunomiya, Daisuke
    Oda, Seitaro
    Komi, Masanori
    Namimoto, Tomohiro
    Hirai, Toshinori
    Hashida, Masahiro
    Takashio, Seiji
    Yamamuro, Megumi
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2013, 20 (06) : 752 - 757
  • [48] 2-STAGE RECOVERY OF A RESPONSE IN SEPIA
    MESSENGER, JB
    NATURE, 1971, 232 (5307) : 202 - +
  • [49] Efficient whole-brain tract-specific T1 mapping at 3T with slice-shuffled inversion-recovery diffusion-weighted imaging
    Leppert, Ilana R.
    Andrews, Daniel A.
    Campbell, Jennifer S. W.
    Park, Daniel J.
    Pike, G. Bruce
    Polimeni, Jonathan R.
    Tardif, Christine L.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 738 - 753
  • [50] A PULSE SEQUENCE FOR T1 MEASUREMENT BY INVERSION RECOVERY IN THE PRESENCE OF ACOUSTIC RINGING
    BAGNO, A
    MAGNETIC RESONANCE IN CHEMISTRY, 1992, 30 (12) : 1164 - 1168