2-STAGE INVERSION-RECOVERY EXPERIMENTS FOR MEASUREMENTS OF T1

被引:7
|
作者
TAITELBAUM, H
FERRETTI, JA
SPENCER, RGS
WEISS, GH
机构
[1] NHLBI,BIOPHYS CHEM LAB,BETHESDA,MD 20892
[2] NIA,CELLULAR & MOLEC BIOL LAB,BALTIMORE,MD 21224
[3] UNIV MARYLAND,INST PHYS SCI & TECHNOL,COLL PK,MD 20742
关键词
D O I
10.1006/jmra.1993.1248
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A theory for the optimal design of experiments for measuring values of T1 using a two-stage design is developed. It is shown that a useful strategy in such designs is to make a preliminary rough estimate of T1 and use the second stage to produce a refinement of the preliminary results. When the initial uncertainty interval for T1 is large, the two-stage design produces results much less sensitive to the value of the true T1 than those obtainable from a single-stage design. This leads to a significant improvement in the precision of estimates of T1, and in circumstances that depend on the value of T1 estimated in the first stage of the experiment, to a considerable saving in spectrometer time. © 1993 by Academic Press, Inc.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [31] Optimized double inversion recovery for reduction of T1 weighting in fluid-attenuated inversion recovery
    Madhuranthakam, Ananth J.
    Sarkar, Subhendra N.
    Busse, Reed F.
    Bakshi, Rohit
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 81 - 88
  • [32] Inversion Recovery at 7 T in the Human Myocardium: Measurement of T1, Inversion Efficiency and B1+
    Rodgers, Christopher T.
    Piechnik, Stefan K.
    DelaBarre, Lance J.
    Van de Moortele, Pierre-Francois
    Snyder, Carl J.
    Neubauer, Stefan
    Robson, Matthew D.
    Vaughan, J. Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) : 1038 - 1046
  • [33] No-wait inversion-a novel model for T1 mapping from inversion recovery measurements without the waiting times
    Bibiano, Juliana
    Kleineisel, Jonas
    Schad, Oliver
    Weng, Andreas Max
    Koestler, Herbert
    Slawig, Anne
    FRONTIERS IN PHYSICS, 2024, 11
  • [34] ''Black blood'' T2-weighted inversion-recovery MR imaging of the heart
    Simonetti, OP
    Finn, JP
    White, RD
    Laub, G
    Henry, DA
    RADIOLOGY, 1996, 199 (01) : 49 - 57
  • [35] Intensity jumping and beating in inversion-recovery experiments of water due to radiation damping
    Chen, JH
    Mao, XA
    Ye, CH
    JOURNAL OF MAGNETIC RESONANCE, 1997, 124 (02) : 490 - 494
  • [36] MR EVALUATION OF VERTEBRAL METASTASES - T1-WEIGHTED, SHORT-INVERSION-TIME INVERSION-RECOVERY, FAST SPIN-ECHO, AND INVERSION-RECOVERY FAST SPIN-ECHO SEQUENCES
    MEHTA, RC
    MARKS, MP
    HINKS, RS
    GLOVER, GH
    ENZMANN, DR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (02) : 281 - 288
  • [37] Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart
    Messroghli, Daniel R.
    Greiser, Andreas
    Froehlich, Mirko
    Dietz, Rainer
    Schulz-Menger, Jeanette
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1081 - 1086
  • [38] 2-PARAMETER LEAST-SQUARES ANALYSIS OF INVERSION-RECOVERY FOURIER-TRANSFORM EXPERIMENTS
    HANSSUM, H
    RUTERJANS, H
    JOURNAL OF MAGNETIC RESONANCE, 1980, 39 (01) : 65 - 78
  • [39] A MODIFIED FAST INVERSION-RECOVERY TECHNIQUE FOR SPIN-LATTICE RELAXATION MEASUREMENTS
    GUPTA, RK
    FERRETTI, JA
    BECKER, ED
    WEISS, GH
    JOURNAL OF MAGNETIC RESONANCE, 1980, 38 (03) : 447 - 452
  • [40] EXTENDED INVERSION RECOVERY METHOD FOR SPIN-LATTICE RELAXATION MEASUREMENTS - A KEY TO ACCURATE T1 DETERMINATION
    EJCHART, A
    OLESKI, P
    WROBLEWSKI, K
    JOURNAL OF MAGNETIC RESONANCE, 1986, 68 (02) : 207 - 216