MEASUREMENT OF SYSTOLIC BLOOD-PRESSURE USING PULSE OXIMETRY DURING HELICOPTER FLIGHT

被引:18
|
作者
TALKE, PO [1 ]
机构
[1] UNIV TEXAS,MED BRANCH,DEPT ANESTHESIOL RES,MED BRANCH,GALVESTON,TX 77550
关键词
TRANSPORTATION OF PATIENTS; VITAL SIGNS; MONITORING; PHYSIOLOGICAL; PULSE OXIMETRY; PLETHYSMOGRAPHY; BLOOD PRESSURE; CRITICAL CARE; SYSTOLE; ELECTROCARDIOGRAPHY; HELICOPTER FLIGHT;
D O I
10.1097/00003246-199107000-00018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Monitoring of vital signs in critically ill patients during helicopter flight is difficult because of the noise and vibrations of the aircraft. We evaluated the use of a pulse oximeter to measure systolic BP intraflight. Design: Systolic BP measured by pulse oximetry was compared with systolic BP measured by the direct intra-arterial and the arterial occulsion methods intraflight. Systolic BP by pulse oximetry was measured by observing the return of the plethysmographic waveform of the pulse oximeter as the BP cuff ipsilateral to the pulse oximeter probe was slowly deflated. Arterial occlusion pressure was measured by observing the return of the intra-arterial waveform as the BP cuff ipsilateral to the arterial cannula was slowly deflated. Setting: The study was performed during patient transport, intraflight. Patients: Ten critically ill patients were studied. Interventions: None. Measurements and Main Results: Seventy-three sets of measurements were recorded. The best correlation (r2 = .99) was found between pulse oximetry and the arterial occlusion method. The indirect methods correlated better with each other than with direct intra-arterial measurements. The noise and the vibrations of the helicopter did not significantly interfere with the operation of the pulse oximeter. Conclusions: We conclude that a pulse oximeter that displays a plethysmographic waveform can accurately measure systolic BP intraflight.
引用
收藏
页码:934 / 937
页数:4
相关论文
共 50 条
  • [41] DETECTION OF DIGITAL ISCHEMIA BY DIRECT MEASUREMENT OF DIGITAL SYSTOLIC BLOOD-PRESSURE
    KRAHENBUHL, B
    CHAMAY, A
    ANNALES DE CHIRURGIE, 1981, 35 (04): : 304 - 308
  • [42] PULSE-RATE AND BLOOD-PRESSURE DURING ADOLESCENCE
    SCHALL, JI
    HEDIGER, ML
    BOWERS, EJ
    GRUSKIN, AB
    KATZ, SH
    PEDIATRIC RESEARCH, 1980, 14 (08) : 1011 - 1011
  • [43] INDIRECT MEASUREMENT OF SYSTOLIC BLOOD-PRESSURE IN LOWER LIMB USING A MERCURY IN RUBBER STRAIN GAUGE
    BELL, G
    NIELSEN, PE
    LASSEN, NA
    WOLFSON, B
    CARDIOVASCULAR RESEARCH, 1973, 7 (02) : 282 - 289
  • [44] A COMPARISON OF PULSE OXIMETERS DURING HELICOPTER FLIGHT
    SHORT, L
    HECKER, RB
    MIDDAUGH, RE
    MENK, EJ
    ANTOPOL, MR
    SOUTHERN MEDICAL JOURNAL, 1988, 81 (09) : S22 - S22
  • [45] PULSE ARRIVAL TIME AS A METHOD OF OBTAINING SYSTOLIC AND DIASTOLIC BLOOD-PRESSURE INDIRECTLY
    GEDDES, LA
    VOELZ, M
    JAMES, S
    REINER, D
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) : 671 - 672
  • [46] Measurement of Central Systolic Blood Pressure by Pulse Volume Plethysmography With a Noninvasive Blood Pressure Monitor
    Sung, Shih-Hsien
    Cheng, Hao-Min
    Chuang, Shao-Yuan
    Shih, Yuan-Ta
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Yu, Wen-Chung
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (05) : 542 - 548
  • [47] Detection of a systolic pressure threshold for reliable readings in pulse oximetry
    Hinkelbein, J
    Genzwuerker, HV
    Fiedler, F
    RESUSCITATION, 2005, 64 (03) : 315 - 319
  • [48] Blood pressure control during eye surgery under local anesthesia using pulse oximetry
    Mamiya, K
    Manabe, M
    Aono, J
    Ueno, H
    OPHTHALMOLOGICA, 1998, 212 (04) : 236 - 238
  • [49] SYSTOLIC OR DIASTOLIC BLOOD-PRESSURE SIGNIFICANCE
    WEISMANN, DN
    PEDIATRICS, 1988, 82 (01) : 112 - 114
  • [50] SYSTOLIC BLOOD-PRESSURE IN A POPULATION OF NEONATES
    SWIET, MD
    FAYERS, P
    SHINEBOURNE, EA
    CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1976, 51 (03): : P7 - P7