MEASUREMENT OF SYSTOLIC BLOOD-PRESSURE USING PULSE OXIMETRY DURING HELICOPTER FLIGHT

被引:18
|
作者
TALKE, PO [1 ]
机构
[1] UNIV TEXAS,MED BRANCH,DEPT ANESTHESIOL RES,MED BRANCH,GALVESTON,TX 77550
关键词
TRANSPORTATION OF PATIENTS; VITAL SIGNS; MONITORING; PHYSIOLOGICAL; PULSE OXIMETRY; PLETHYSMOGRAPHY; BLOOD PRESSURE; CRITICAL CARE; SYSTOLE; ELECTROCARDIOGRAPHY; HELICOPTER FLIGHT;
D O I
10.1097/00003246-199107000-00018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Monitoring of vital signs in critically ill patients during helicopter flight is difficult because of the noise and vibrations of the aircraft. We evaluated the use of a pulse oximeter to measure systolic BP intraflight. Design: Systolic BP measured by pulse oximetry was compared with systolic BP measured by the direct intra-arterial and the arterial occulsion methods intraflight. Systolic BP by pulse oximetry was measured by observing the return of the plethysmographic waveform of the pulse oximeter as the BP cuff ipsilateral to the pulse oximeter probe was slowly deflated. Arterial occlusion pressure was measured by observing the return of the intra-arterial waveform as the BP cuff ipsilateral to the arterial cannula was slowly deflated. Setting: The study was performed during patient transport, intraflight. Patients: Ten critically ill patients were studied. Interventions: None. Measurements and Main Results: Seventy-three sets of measurements were recorded. The best correlation (r2 = .99) was found between pulse oximetry and the arterial occlusion method. The indirect methods correlated better with each other than with direct intra-arterial measurements. The noise and the vibrations of the helicopter did not significantly interfere with the operation of the pulse oximeter. Conclusions: We conclude that a pulse oximeter that displays a plethysmographic waveform can accurately measure systolic BP intraflight.
引用
收藏
页码:934 / 937
页数:4
相关论文
共 50 条
  • [21] PULSE SOUNDS AND MEASUREMENT OF DIASTOLIC BLOOD-PRESSURE IN CHILDREN
    UHARI, M
    NUUTINEN, M
    TURTINEN, J
    POKKA, T
    LANCET, 1991, 338 (8760): : 159 - 161
  • [22] DISCRIMINATION OF SYSTOLIC BLOOD-PRESSURE
    VIDERGAR, LJ
    LEE, RM
    GOLDMAN, MS
    BIOFEEDBACK AND SELF-REGULATION, 1983, 8 (01): : 45 - 61
  • [23] SYSTOLIC BLOOD-PRESSURE IN NEWBORN
    GILL, D
    OBRIEN, NG
    IRISH MEDICAL JOURNAL, 1977, 70 (14) : 419 - 420
  • [24] Use of pulse oximetry for blood pressure measurement after cardiac surgery
    Movius, AJ
    Bratton, SL
    Sorensen, GK
    ARCHIVES OF DISEASE IN CHILDHOOD, 1998, 78 (05) : 457 - 460
  • [25] Detection of a systolic pulse pressure level for reliable readings in pulse oximetry
    Hinkelbein, J.
    Genzwuerker, H.
    Fiedler, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 42 - 42
  • [26] PULSE AND BLOOD-PRESSURE
    FORREST, JB
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1982, 29 : S15 - S27
  • [27] INSTRUCTIONS TO CHANGE BLOOD-PRESSURE AND DIASTOLIC BLOOD-PRESSURE BIOFEEDBACK - THEIR EFFECTS ON DIASTOLIC BLOOD-PRESSURE, SYSTOLIC BLOOD-PRESSURE AND ANXIETY
    LUTZ, DJ
    HOLMES, DS
    JOURNAL OF PSYCHOSOMATIC RESEARCH, 1981, 25 (06) : 479 - 485
  • [28] VOLUNTARY CONTROL OF SYSTOLIC BLOOD-PRESSURE DURING POSTURAL CHANGE
    VICTOR, R
    WEIPERT, D
    SHAPIRO, D
    PSYCHOPHYSIOLOGY, 1984, 21 (06) : 673 - 682
  • [29] MEASUREMENT OF ARTERIAL BLOOD-PRESSURE DURING ANESTHESIA
    STAFFORD, MA
    BATCHELOR, AM
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1992, 47 (07) : 533 - 536
  • [30] MEASUREMENT OF BLOOD-PRESSURE DURING INDUCED HYPOTENSION
    CSONGRADY, A
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1981, 16 (02): : 112 - 117