摘要
The authors previously found that positively charged substances are less well-transported into the vitreous humor by transscleral iontophoresis than are negatively charged substances. There was more bubble formation in the eye cup with positively charged than with negatively charged substances. The authors hypothesized that these bubbles might account for the poorer conductance of the positively charged species by causing interruptions of the current. Therefore, the authors developed a modified eye cup in which the diameter of the fluid column was larger than that in the old device (1.0 rather than 0.5 mm). This modification allowed larger voltage to be applied than with the older device, because bubbles could be more easily cleared from the conjunctiva than with the narrower-bore eye cup. Although the efficiency of the apparatus was the same with the two eve cups (micrograms per milliliter in vitreous humor divided by milliampere minutes of current applied), vitreal concentrations of gentamicin with the modified eye cup were fourfold higher than with the older eye cup (83 versus 19 mug/ml; P < 0.001). These studies suggest that modifying the eye cup to permit easier removal of bubbles resulted in improved delivery of gentamicin into the ocular humors.
引用
收藏
页码:3543 / 3545
页数:3
相关论文
共 50 条
  • [41] Iontophoresis using a hydrogel-gentamicin containing probe in rabbit cornea.
    Mechoulam, H
    Raiskup, F
    Hazarrassanov, RM
    Verman, M
    Ever-Hadani, P
    Domb, A
    Frucht-Pery, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S35 - S35
  • [43] Iontophoresis-gentamicin delivery into the rabbit cornea, using a hydrogel delivery probe
    Frucht-Pery, J
    Mechoulam, H
    Siganos, CS
    Ever-Hadani, P
    Shapiro, M
    Domb, A
    EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) : 745 - 749
  • [44] Examination of penetration routes and distribution of ionic permeants during and after transscleral iontophoresis with magnetic resonance imaging
    Molokhia, Sarah A.
    Jeong, Eun-Kee
    Higuchi, William I.
    Li, S. Kevin
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2007, 335 (1-2) : 46 - 53
  • [45] Evaluation of Ocular and General Safety Following Repeated Dosing of Dexamethasone Phosphate Delivered by Transscleral Iontophoresis in Rabbits
    Patane, Michael A.
    Schubert, William
    Sanford, Thomas
    Gee, Raymond
    Burgos, Melissa
    Isom, William P.
    Ruiz-Perez, Begona
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2013, 29 (08) : 760 - 769
  • [46] Iontophoresis for drug delivery into the nail apparatus: exploring hyponychium as the site of delivery
    Kushwaha, Avadhesh
    Shivakumar, H. N.
    Murthy, S. Narasimha
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2016, 42 (10) : 1678 - 1682
  • [47] GENTAMICIN IONTOPHORESIS IN THE TREATMENT OF BACTERIAL OTITIS-EXTERNA IN THE GUINEA-PIG MODEL
    KING, DM
    ESTREM, SA
    LARYNGOSCOPE, 1990, 100 (10): : 1112 - 1115
  • [48] Improved myothermic apparatus
    Hill, AV
    Weizsacker, V
    JOURNAL OF PHYSIOLOGY-LONDON, 1914, 48 (06):
  • [49] AN IMPROVED EXPOSURE APPARATUS
    Dodge, Raymond
    PSYCHOLOGICAL BULLETIN, 1907, 4 (01) : 10 - 13
  • [50] AN IMPROVED ELECTROMICROCAUTER APPARATUS
    RIGGLE, GC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (05): : 402 - 402