AN IMPROVED APPARATUS FOR TRANSSCLERAL IONTOPHORESIS OF GENTAMICIN

被引:0
|
作者
CHURCH, AL [1 ]
BARZA, M [1 ]
BAUM, J [1 ]
机构
[1] NEW ENGLAND MED CTR,DEPT MED,DIV GEOGR MED & INFECT DIS,750 WASHINGTON ST,BOX 009,BOSTON,MA 02111
关键词
BUBBLE; EYE; GENTAMICIN; IONTOPHORESIS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The authors previously found that positively charged substances are less well-transported into the vitreous humor by transscleral iontophoresis than are negatively charged substances. There was more bubble formation in the eye cup with positively charged than with negatively charged substances. The authors hypothesized that these bubbles might account for the poorer conductance of the positively charged species by causing interruptions of the current. Therefore, the authors developed a modified eye cup in which the diameter of the fluid column was larger than that in the old device (1.0 rather than 0.5 mm). This modification allowed larger voltage to be applied than with the older device, because bubbles could be more easily cleared from the conjunctiva than with the narrower-bore eye cup. Although the efficiency of the apparatus was the same with the two eve cups (micrograms per milliliter in vitreous humor divided by milliampere minutes of current applied), vitreal concentrations of gentamicin with the modified eye cup were fourfold higher than with the older eye cup (83 versus 19 mug/ml; P < 0.001). These studies suggest that modifying the eye cup to permit easier removal of bubbles resulted in improved delivery of gentamicin into the ocular humors.
引用
收藏
页码:3543 / 3545
页数:3
相关论文
共 50 条
  • [21] Distribution of amikacin in the rabbit eye following transscleral iontophoresis.
    Miller, DJ
    Desjardins, J
    Abbot, E
    Chlipala, E
    Bendele, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S767 - S767
  • [22] In vitro transscleral iontophoresis of high molecular weight neutral compounds
    Nicoli, Sara
    Ferrari, Giulio
    Quarta, Marinella
    Macaluso, Claudio
    Santi, Patrizia
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 36 (4-5) : 486 - 492
  • [23] Transscleral Iontophoresis of cortcicosteoids: Phase II clinical trial.
    Chauvaud, D
    Behar-Cohen, FF
    Parel, JM
    Renard, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S79 - S79
  • [24] Transscleral coulomb controlled iontophoresis of ganciclovir in rabbits: Safety and pharmacokinetics
    Gautier, S
    Kasner, L
    BeharCohen, F
    ElAouni, A
    Kondo, H
    OGrady, G
    Davis, JL
    Parel, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 720 - 720
  • [25] Hydrogel iontophoresis for gentamicin administration to the rabbit eye
    Eljarrat-Binstock, E
    Raiskup, F
    Frucht-Pery, J
    Domb, AJ
    Ophthalmic Technologies XV, 2005, 5688 : 234 - 239
  • [26] GENTAMICIN IN VENTILATION APPARATUS
    FANLUN, P
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1976, 115 (10) : 976 - 976
  • [27] Intraocular tissues pharmacokinetics of ganciclovir transscleral Coulomb controlled iontophoresis in rabbits
    Chapon, P
    Voigt, M
    Gautier, S
    Behar-Cohen, F
    O'Grady, G
    Parel, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S189 - S189
  • [28] Transcorneal and transscleral iontophoresis of dexamethasone phosphate using drug loaded hydrogel
    Eljarrat-Binstock, E
    Raiskup, F
    Frucht-Pery, J
    Domb, AJ
    JOURNAL OF CONTROLLED RELEASE, 2005, 106 (03) : 386 - 390
  • [29] The Research of AC-Pulse Iontophoresis Apparatus
    Su, Man
    Yue, Caixiang
    Wang, Lili
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON INFORMATION SCIENCES, MACHINERY, MATERIALS AND ENERGY (ICISMME 2015), 2015, 126 : 1181 - 1184
  • [30] Dexamethasone application to the canine eye with transscleral Coulomb-controlled iontophoresis (CCI)
    Komaromy, AM
    Acland, GM
    Aguirre, GD
    Parel, JM
    Jacobson, SG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46