SIMULTANEOUS DETERMINATION OF URIC-ACID, XANTHINE AND HYPOXANTHINE WITH AN ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODE

被引:33
|
作者
CAI, X
KALCHER, K
NEUHOLD, C
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,UNIV PLATZ 1,A-8010 GRAZ,AUSTRIA
[2] HAINAN UNIV,COLL SCI & TECHNOL,HAINAN,PEOPLES R CHINA
来源
关键词
D O I
10.1007/BF00325569
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method is presented for the simultaneous differential pulse voltammetric determination of uric acid, xanthine and hypoxanthine. It is based on the improved current responses of the three analytes at carbon paste electrodes polarized in a dilute alkaline medium (0.002 mol/l NaOH, 0.1 mol/l NaClO4) at 1.3 V vs. SCE for a short time. Compared with the methods reported in the literature, this procedure has a much wider linear range (2 to 3 orders of magnitude in concentration), lower detection limits (5 to 10 mug 1(-1) and less interference by ascorbic acid. The electrochemical responses were found to be dependent on the pre-anodization potential and the time imposed on the electrodes as well as on the alkalinity of the supporting electrolyte. The proposed procedure was used to determine uric acid, xanthine and hypoxanthine in human urine without any preliminary treatment.
引用
收藏
页码:660 / 665
页数:6
相关论文
共 50 条
  • [41] Electrochemically pretreated zeolite-modified carbon-paste electrodes for determination of linuron in an agricultural formulation and water
    Siara, L. R.
    de Lima, F.
    Cardoso, C. A. L.
    Arruda, G. J.
    ELECTROCHIMICA ACTA, 2015, 151 : 609 - 618
  • [42] SIMULTANEOUS DETERMINATION OF HYDROQUINONE ETHERS IN COSMETICS AFTER PRECONCENTRATION AT A CARBON-PASTE ELECTRODE
    WANG, LH
    ANALYST, 1995, 120 (08) : 2241 - 2244
  • [43] DETERMINATION OF URIC-ACID AND XANTHINE HYPOXANTHINE IN BLOOD USING IMMOBILIZED ENZYMES IN FLOW-INJECTION SYSTEM
    HUSSAIN, G
    YAQOOB, M
    NABI, A
    MASOOM, M
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1995, 17 (02): : 109 - 112
  • [44] Simultaneous Determination of Uric Acid, Xanthine and Hypoxanthine in Human Plasma and Serum by HPLC–UV: Uric Acid Metabolism Tracking
    Anna Pleskacova
    Stanislav Brejcha
    Lukas Pacal
    Katerina Kankova
    Josef Tomandl
    Chromatographia, 2017, 80 : 529 - 536
  • [45] SIMULTANEOUS DETERMINATION OF LEAD, COPPER, AND MERCURY AT A MODIFIED CARBON-PASTE ELECTRODE CONTAINING HUMIC-ACID
    JEONG, ED
    WON, MS
    SHIM, YB
    ELECTROANALYSIS, 1994, 6 (10) : 887 - 893
  • [46] Simultaneous Voltammetric Determination of Norepinephrine, Ascorbic Acid and Uric Acid by TTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Vishwanatha, Chandrashekar C.
    Kumar, Mohan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (05): : 555 - 573
  • [47] Application of a modified carbon nanotube paste electrode for simultaneous determination of epinephrine, uric acid and folic acid
    Beitollahi, Hadi
    Mohadesi, Alireza
    Mahani, Saeedeh Khalilizadeh
    Akbari, Ali
    ANALYTICAL METHODS, 2012, 4 (04) : 1029 - 1035
  • [48] Simultaneous determination of uric acid, xanthine and hypoxanthine at poly(pyrocatechol violet)/functionalized multi-walled carbon nanotubes composite film modified electrode
    Wang, Yan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 88 (02) : 614 - 621
  • [49] Graphitized mesoporous carbon modified glassy carbon electrode for selective sensing of xanthine, hypoxanthine and uric acid
    Thangaraj, Rajendiran
    Kumar, Annamalai Senthil
    ANALYTICAL METHODS, 2012, 4 (07) : 2162 - 2171
  • [50] XANTHINE INTERFERENCE IN THE KODAK EKTACHEM DETERMINATION OF URIC-ACID
    POTTER, JL
    CLINICAL CHEMISTRY, 1987, 33 (07) : 1265 - 1265