CLINICAL AND ANGIOGRAPHIC RESULTS OF BALLOON-EXPANDABLE INTRACORONARY STENTS IN RIGHT CORONARY-ARTERY STENOSES

被引:91
|
作者
LEVINE, MJ
LEONARD, BM
BURKE, JA
NASH, ID
SAFIAN, RD
DIVER, DJ
BAIM, DS
机构
[1] BETH ISRAEL HOSP,DEPT MED,DIV CARDIOVASC,HARVARD THORNDIKE LAB,330 BROOKLINE AVE,BOSTON,MA 02215
[2] CHARLES A DANA RES INST,BOSTON,MA
关键词
D O I
10.1016/0735-1097(90)90582-A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon-expandable stents were placed successfully in 35 (95%) of 37 patients whose right coronary artery lesion was believed to have a poor short- or long-term prognosis with conventional balloon angioplasty because of prior restenosis or adverse lesion morphology. Quantitative angiography showed a reduction in stenosis diameter from 83 ± 14% to 42 ± 14% after conventional balloon dilation, with a further reduction to - 3 ± 12% after stent placement (p < 0.001). There were no acute stent thromboses, but one patient (with two stents and unstented distal disease) developed subacute thrombosis on day 8 after self-discontinuation of warfarin and was treated with thrombolytic therapy and reflation. Follow-up angiography was performed at 4 to 6 months in 25 patients, demonstrating restenosis (83 ± 13%) in 4 (57%) of 7 patients with multiple stents, but only 3 (17%) of 18 patients with a single stent (p < 0.05). Six of the seven in-stent restenotic lesions were subtotal (80 ± 12%) and were subjected to repeat conventional balloon angioplasty (postdilation stenosis 13 ± 21%). The 18 patients without restenosis had a maximal in-stent diameter stenosis of 29 ± 15%, corresponding to a maximal focal neointimal thickness of 0.68 ± 0.26 mm within the stented segment. These preliminary results suggest that the Schatz-Palmaz stent may be a useful adjunctive device in the performance of coronary angioplasty. © 1990.
引用
收藏
页码:332 / 339
页数:8
相关论文
共 50 条
  • [41] Computational fluid dynamics analysis of balloon-expandable coronary stents: Influence of stent and vessel deformation
    Martin, David M.
    Murphy, Eoin A.
    Boyle, Fergal J.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (08) : 1047 - 1056
  • [42] LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN SAPHENOUS-VEIN GRAFTS - A REPORT FROM THE CORE ANGIOGRAPHIC LABORATORY
    FENTON, S
    FISCHMAN, D
    SAVAGE, M
    SCHATZ, R
    GOLDBERG, S
    [J]. CIRCULATION, 1993, 88 (04) : 308 - 308
  • [43] Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis
    David Martin
    Fergal Boyle
    [J]. Cardiovascular Engineering and Technology, 2015, 6 : 314 - 328
  • [44] RESTRICTION OF INSTRUMENTAL ENDARTERECTOMY OF THE RIGHT CORONARY-ARTERY (ACD) BASED ON CLINICAL AND ANGIOGRAPHIC LONG-TERM RESULTS
    ESCHENBRUCH, EM
    GORNANDT, L
    TOLLENAERE, P
    SCHMUZIGER, M
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1982, 30 (01): : 15 - 15
  • [45] QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS
    HAUDE, M
    ERBEL, R
    ISSA, H
    MEYER, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) : 26 - 34
  • [46] Angiographic outcomes in self-expanding and balloon-expandable stents: Importance of procedural technique in determining late patency
    Wilson, SH
    Han, RO
    Schwartz, RS
    Goldberg, S
    [J]. CIRCULATION, 1998, 98 (17) : 160 - 160
  • [47] Radial force and wall apposition of balloon-expandable vascular stents in eccentric stenoses:: An in vitro evaluation in a curved vessel model
    Kalmár, G
    Hübner, F
    Voelker, W
    Hutzenlaub, J
    Teubner, J
    Poerner, T
    Süselbeck, T
    Borggrefe, M
    Haase, KK
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (05) : 499 - 508
  • [48] STENTING OF THE RIGHT CORONARY-ARTERY FOR DE-NOVO STENOSES - A COMPARISON OF THE WIKTOR AND THE PALMAZ-SCHATZ STENTS
    GOY, JJ
    EECKHOUT, E
    STAUFFER, JC
    VOGT, P
    [J]. CIRCULATION, 1995, 92 (08) : 2558 - 2558
  • [49] Implantation of balloon-expandable stents for coarctation of the aorta: Implantation data and short-term results
    Bulbul, ZR
    Bruckheimer, E
    Love, JC
    Fahey, JT
    Hellenbrand, WE
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 39 (01): : 36 - 42
  • [50] Treatment of recurrent nasolacrimal duct obstructions with balloon-expandable metallic stents: Results of early experience
    Ilgit, ET
    Yuksel, D
    Unal, M
    Akpek, S
    Isik, S
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (04) : 657 - 663