Implantation of balloon-expandable stents for coarctation of the aorta: Implantation data and short-term results

被引:0
|
作者
Bulbul, ZR [1 ]
Bruckheimer, E [1 ]
Love, JC [1 ]
Fahey, JT [1 ]
Hellenbrand, WE [1 ]
机构
[1] YALE UNIV,SCH MED,DEPT PEDIAT,PEDIAT CARDIOL SECT,NEW HAVEN,CT 06520
来源
关键词
coarctation; stent; aorta; native; recurrent; angioplasty;
D O I
10.1002/(SICI)1097-0304(199609)39:1<36::AID-CCD7>3.0.CO;2-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report the immediate results and the short-term follow-up in a group of selected patients with coarctation of the aorta who underwent endovascular stent implantation. Balloon-expandable stents were implanted in 6 patients (mean age 19.8 +/- 5.1 years) with coarctation of the aorta (4 recurrent and 2 native) who underwent a total of 7 procedures (6 implantation and 1 further expansion). The systolic peak pressure gradient was decreased from 36.7 +/- 16.9 to 13.3 +/- 23.2 mm Hg (P < 0.005). There was a 66% increase in the mean coarctation diameter from 9.3 +/- 1.7 to 15.6 +/- 3.1 mm (P = 0.001) with the ratio of the coarctation to descending aorta diameter, measured at the level of the diaphragm, increasing from 0.49 +/- 0.1 to 0.81 +/- 0.2 (P < 0.005). The dilatation was successful in expanding the stent to an acceptable diameter in 5 of 6 patients. One patient underwent successful further expansion of a stent implanted 22 months previously. There were no immediate complications during balloon expansion and stent implantation. One patient suffered a femoral arterial bleed requiring surgical repair. There was one unrelated death. All patients were hypertensive (systolic blood pressure >140 mm Hg) prior to stent implantation. At mean follow-up of 8 months, 3 patients are normotensive. There was no recurrence of coarctation, aortic dissection, or aneurysm formation in the patients in whom stent implantation was successful. These findings indicate that balloon-expandable stent implantation for coarctation of the aorta in selected patients is a safe and effective alternative approach for relieving the obstruction with a low complication rate and no recoarctation at short-term follow-up. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 50 条
  • [1] Late hemodynamic and anatomic results of balloon-expandable stent implantation for coarctation of the aorta
    Chung, AM
    Perry, SB
    Keane, JF
    Lock, JE
    [J]. CIRCULATION, 1997, 96 (08) : 3179 - 3179
  • [2] Balloon-expandable stents for native coarctation of the aorta in children and adolescents
    Kasar, Taner
    Erkut, Ozturk
    Tanidir, I. Cansaran
    Sahin, Murat
    Topkarci, M. Akin
    Guzeltas, Alper
    [J]. MEDICINE, 2022, 101 (51)
  • [3] Self- and balloon-expandable stent implantation for severe native coarctation of aorta in adults
    Tyagi, S
    Singh, S
    Mukhipadhyay, S
    Kaul, UA
    [J]. AMERICAN HEART JOURNAL, 2003, 146 (05) : 920 - 928
  • [4] Long segment coarctation of the thoracic aorta: Treatment with multiple balloon-expandable stent implantation
    Thanopoulos, B
    Triposkiadis, F
    Margetakis, A
    Mullins, CE
    [J]. AMERICAN HEART JOURNAL, 1997, 133 (04) : 470 - 473
  • [5] Use of balloon-expandable stents for coarctation of the aorta: Initial results and intermediate-term follow-up
    Ebeid, MR
    Prieto, LR
    Latson, LA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) : 1847 - 1852
  • [6] Short-Term outcomes using contemporary balloon-expandable valves in transcatheter aortic valve implantation
    Medranda, G.
    Schwartz, R. K.
    Green, S. J.
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 : 1647 - 1647
  • [7] MULTICENTER RESULTS AFTER CORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS
    HAUDE, M
    ERBEL, R
    HAFNER, G
    HEUBLEIN, B
    HOEPP, HW
    FRANZEN, D
    PRELLWITZ, W
    LICHTLEN, P
    HILGER, HH
    MEYER, J
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1993, 82 (02): : 77 - 86
  • [8] Self-Expanding Versus Balloon-Expandable Stents in Patients With Isthmic Coarctation of the Aorta
    Firoozi, Ata
    Mohebbi, Bahram
    Noohi, Feridoun
    Bassiri, Hosseinali
    Mohebbi, Ahmad
    Abdi, Seifollah
    Maleki, Majid
    Shafe, Omid
    Peighambari, Mohammad Mehdi
    Alemzadeh-Ansari, Mohammad Javad
    Bakhshandeh, Hooman
    Rezaei, Yousef
    Sepehrvand, Nariman
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (06): : 1062 - 1067
  • [9] BALLOON-EXPANDABLE STENT REPAIR OF SEVERE COARCTATION OF AORTA
    DELEZO, JS
    PAN, M
    ROMERO, M
    MEDINA, A
    SEGURA, J
    PAVLOVIC, D
    MARTINEZ, C
    TEJERO, I
    NAVERO, JP
    TORRES, F
    LAFUENTE, M
    HERNANDEZ, E
    MELIAN, F
    CONCHA, M
    [J]. AMERICAN HEART JOURNAL, 1995, 129 (05) : 1002 - 1008
  • [10] IMPLANTATION OF BALLOON-EXPANDABLE INTRAVASCULAR STENTS IN PATIENTS WITH CONGENITAL HEART-DISEASE
    OLAUGHLIN, MP
    PERRY, SB
    LOCK, JE
    MULLINS, CE
    [J]. CIRCULATION, 1990, 82 (04) : 658 - 658