Implantation of balloon-expandable stents for coarctation of the aorta: Implantation data and short-term results

被引:0
|
作者
Bulbul, ZR [1 ]
Bruckheimer, E [1 ]
Love, JC [1 ]
Fahey, JT [1 ]
Hellenbrand, WE [1 ]
机构
[1] YALE UNIV,SCH MED,DEPT PEDIAT,PEDIAT CARDIOL SECT,NEW HAVEN,CT 06520
来源
关键词
coarctation; stent; aorta; native; recurrent; angioplasty;
D O I
10.1002/(SICI)1097-0304(199609)39:1<36::AID-CCD7>3.0.CO;2-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report the immediate results and the short-term follow-up in a group of selected patients with coarctation of the aorta who underwent endovascular stent implantation. Balloon-expandable stents were implanted in 6 patients (mean age 19.8 +/- 5.1 years) with coarctation of the aorta (4 recurrent and 2 native) who underwent a total of 7 procedures (6 implantation and 1 further expansion). The systolic peak pressure gradient was decreased from 36.7 +/- 16.9 to 13.3 +/- 23.2 mm Hg (P < 0.005). There was a 66% increase in the mean coarctation diameter from 9.3 +/- 1.7 to 15.6 +/- 3.1 mm (P = 0.001) with the ratio of the coarctation to descending aorta diameter, measured at the level of the diaphragm, increasing from 0.49 +/- 0.1 to 0.81 +/- 0.2 (P < 0.005). The dilatation was successful in expanding the stent to an acceptable diameter in 5 of 6 patients. One patient underwent successful further expansion of a stent implanted 22 months previously. There were no immediate complications during balloon expansion and stent implantation. One patient suffered a femoral arterial bleed requiring surgical repair. There was one unrelated death. All patients were hypertensive (systolic blood pressure >140 mm Hg) prior to stent implantation. At mean follow-up of 8 months, 3 patients are normotensive. There was no recurrence of coarctation, aortic dissection, or aneurysm formation in the patients in whom stent implantation was successful. These findings indicate that balloon-expandable stent implantation for coarctation of the aorta in selected patients is a safe and effective alternative approach for relieving the obstruction with a low complication rate and no recoarctation at short-term follow-up. (C) 1996 Wiley-Liss, Inc.
引用
下载
收藏
页码:36 / 42
页数:7
相关论文
共 50 条
  • [21] Self-expandable valve implantation within a failed balloon-expandable valve
    Kornowski, Ran
    Codner, Pablo
    Vaknin-Assa, Hana
    Assali, Abid
    EUROINTERVENTION, 2014, 10 (08) : 1001 - 1001
  • [22] LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN AORTOCORONARY SAPHENOUS-VEIN GRAFTS
    FENTON, SH
    FISCHMAN, DL
    SAVAGE, MP
    SCHATZ, RA
    LEON, MB
    BAIM, DS
    KING, SB
    HEUSER, RR
    CURRY, RC
    RAKE, RC
    GOLDBERG, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (12): : 1187 - 1191
  • [23] USE OF BALLOON-EXPANDABLE STENTS IN THE TRACHEOBRONCHIAL SYSTEM - MIDTERM RESULTS
    LIERMANN, DD
    BECKER, HD
    LOERCHER, U
    KRONENBERGER, H
    KOLLATH, J
    RADIOLOGY, 1992, 185 : 294 - 294
  • [24] Balloon-expandable cheatham-platinum stents versus self-expandable nitinol stents in coarctation of aorta: 3-year outcome of a randomized clinical trial
    Sadeghipour, P.
    Pouraliakbar, H. R.
    Farrashi, M.
    Khorasani, S. Habibi
    Mohebbi, B.
    Iranian, M. R.
    Babaei, M. R.
    Forouzannia, S. M.
    Afrooghe, A.
    Firouzi, A.
    Hoseini, F.
    Khajali, Z.
    Saedi, S.
    Haulon, S.
    Moosavi, J.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [25] Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    Liang, DK
    Yang, DZ
    Qi, M
    Wang, WQ
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (03) : 314 - 318
  • [26] Comparison of Balloon-expandable and Self-expandable Bioprosthesis for Transcatheter Aortic Valve Implantation
    Napodano, Massimo
    Gasparetto, Valeria
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Yzeiraj, Ermela
    Buja, Paolo
    Pittarello, Demetrio
    D'Onofrio, Augusto
    Gerosa, Gino
    Isabella, Giambattista
    Iliceto, Sabino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B39 - B39
  • [27] BALLOON-EXPANDABLE STENT TREATMENT OF EXPERIMENTAL COARCTATION OF THE AORTA - EARLY HEMODYNAMIC AND PATHOLOGICAL EVALUATION
    BEEKMAN, RH
    MULLER, DWM
    REYNOLDS, PI
    MOOREHEAD, C
    HEIDELBERGER, K
    LUPINETTI, FM
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1993, 6 (02) : 113 - 123
  • [28] Stent Implantation and Balloon Angioplasty for Native and Recurrent Coarctation of the Aorta
    Cheng, Wei
    Li, Zhiqiang
    Ye, Zankai
    Zhu, Yaobin
    Ding, Nan
    Yan, Daole
    Yi, Hanlu
    Zhang, Jinrui
    Ni, Xin
    INTERNATIONAL HEART JOURNAL, 2023, 64 (01) : 10 - 21
  • [29] Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation
    Bonaros, Nikolaos
    Kofler, Markus
    Frank, Derk
    Cocchieri, Riccardo
    Jagielak, Dariusz
    Aiello, Marco
    Lapeze, Joel
    Laine, Mika
    Chocron, Sidney
    Muir, Douglas
    Eichinger, Walter
    Thielmann, Matthias
    Labrousse, Louis
    Bapat, Vinayak
    Rein, Kjell Arne
    Verhoye, Jean-Philippe
    Gerosa, Gino
    Baumbach, Hardy
    Deutsch, Cornelia
    Bramlage, Peter
    Thoenes, Martin
    Romano, Mauro
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (03): : 915 - 923
  • [30] Bail-Out Implantation of an Embolized Balloon-Expandable Transcatheter Heart Valve in the Aortic Arch Using Self-Expandable Stents
    Dreger, Henryk
    Suendermann, Simon
    Niehues, Stefan M.
    Landmesser, Ulf
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 180 : 163 - 164