LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN AORTOCORONARY SAPHENOUS-VEIN GRAFTS

被引:94
|
作者
FENTON, SH
FISCHMAN, DL
SAVAGE, MP
SCHATZ, RA
LEON, MB
BAIM, DS
KING, SB
HEUSER, RR
CURRY, RC
RAKE, RC
GOLDBERG, S
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DIV CARDIOL,PHILADELPHIA,PA 19107
[2] SCRIPPS CLIN & RES CTR,LA JOLLA,CA
[3] WASHINGTON CARDIOL CTR,WASHINGTON,DC
[4] BETH ISRAEL HOSP,BOSTON,MA 02215
[5] EMORY UNIV,ATLANTA,GA 30322
[6] ARIZONA HEART INST,PHOENIX,AZ
[7] FLORIDA HEART INST,ORLANDO,FL
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1994年 / 74卷 / 12期
关键词
D O I
10.1016/0002-9149(94)90545-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon angioplasty of aortocoronary saphenous vein graft lesions is associated with high restenosis and clinical event rates. the goal of this multicenter study was to assess long-term angiographic and clinical outcome of patients electively treated with single Palmaz-Schatz stents in aortocoronary saphenous vein grafts. In 198 patients (209 lesions), elective placement of single Palmaz-Schatz stents was attempted. Angiography was performed at baseline, immediately after stent placement, and at 6-month follow-up. Stent placement was successful in 98.5% of patients. One patient (0.5%) had stent thrombosis. Restenosis occurred in 34% (45 of 133) of the restudied lesions. Restenosis was lower in de novo lesions than in restenotic lesions (22% vs 51%, p <0.001). Ostial lesions had a higher restenosis rate than nonostial lesions (61% vs 28%, p = 0.003). Freedom from death, myocardial infarction, coronary artery bypass surgery, and repeat angioplasty was present in 70% of patients. Eighty-two percent of patients with de novo lesions remained event-free at 1 year, whereas only 55% of patients with prior angioplasty were event-free at 1 year (p <0.001). The use of the Palmaz-Schatz stent for the treatment of focal, de novo, aortocoronary saphenous vein graft lesions is associated with a high procedural success rate, a low angiographic restenosis rate, and low clinical event rates, including the need for repeat revascularization. The results of this study need validation by a prospective randomized trial comparing stent implantation with angioplasty.
引用
收藏
页码:1187 / 1191
页数:5
相关论文
共 50 条
  • [1] LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN SAPHENOUS-VEIN GRAFTS - A REPORT FROM THE CORE ANGIOGRAPHIC LABORATORY
    FENTON, S
    FISCHMAN, D
    SAVAGE, M
    SCHATZ, R
    GOLDBERG, S
    CIRCULATION, 1993, 88 (04) : 308 - 308
  • [2] LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF A BALLOON-EXPANDABLE STENT IN THE NATIVE CORONARY CIRCULATION
    SAVAGE, MP
    FISCHMAN, DL
    SCHATZ, RA
    TEIRSTEIN, PS
    LEON, MB
    BAIM, D
    ELLIS, SG
    TOPOL, EJ
    HIRSHFELD, JW
    CLEMAN, MW
    BUCHBINDER, M
    BAILEY, S
    HEUSER, R
    WALKER, CM
    CURRY, RC
    GEBHARDT, S
    RAKE, R
    GOLDBERG, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) : 1207 - 1212
  • [3] Long-term clinical outcome after stent implantation in saphenous vein grafts
    deJaegere, PP
    vanDomburg, RT
    deFeyter, PJ
    Ruygrok, PN
    vanderGiessen, WJ
    vandenBrand, MJ
    Serruys, PW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (01) : 89 - 96
  • [4] LONG-TERM DURABILITY OF PATENT SAPHENOUS-VEIN AORTOCORONARY BYPASS GRAFTS
    ITSCOITZ, SB
    REDWOOD, DR
    GRAUER, LE
    REIS, RL
    STINSON, EB
    EPSTEIN, SE
    AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01): : 146 - 146
  • [5] EVALUATION OF EARLY AND LONG-TERM FUNCTION OF AORTOCORONARY SAPHENOUS-VEIN GRAFTS
    YACOUB, M
    FAWZY, E
    AHMED, M
    WESTBURY, H
    NWAFO, D
    BENNETT, M
    TOWERS, M
    BRITISH HEART JOURNAL, 1976, 38 (05): : 532 - 533
  • [6] EARLY RESULTS OF STENT IMPLANTATION IN AORTOCORONARY SAPHENOUS-VEIN GRAFTS
    LEON, MB
    PICHARD, AD
    BAIM, DS
    ELLIS, S
    HIRSHFELD, J
    TEIRSTEIN, PS
    SCHATZ, RS
    CIRCULATION, 1990, 82 (04) : 679 - 679
  • [7] INTRACORONARY STENTS FOR ANGIOPLASTY OF STENOSES OF SAPHENOUS-VEIN AORTOCORONARY BYPASS GRAFTS
    CRIPPS, TR
    BULLER, NP
    RICKARDS, AF
    BRITISH HEART JOURNAL, 1990, 64 (01): : 62 - 63
  • [8] AORTOCORONARY BYPASS WITH HOMOLOGOUS SAPHENOUS-VEIN - LONG-TERM RESULTS
    BICAL, O
    BACHET, J
    LAURIAN, C
    CAMILLERI, JP
    GOUDOT, B
    MENU, P
    GUILMET, D
    ANNALS OF THORACIC SURGERY, 1980, 30 (06): : 550 - 557
  • [9] ENDOLUMINAL STENTING OF NARROWED SAPHENOUS-VEIN GRAFTS - LONG-TERM CLINICAL AND ANGIOGRAPHIC FOLLOW-UP
    EECKHOUT, E
    GOY, JJ
    STAUFFER, JC
    VOGT, P
    KAPPENBERGER, L
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (02): : 139 - 146
  • [10] LONG-TERM ANGIOGRAPHIC ASSESSMENT OF INFLUENCE OF CORONARY RISK-FACTORS ON NATIVE CORONARY CIRCULATION AND SAPHENOUS-VEIN AORTOCORONARY GRAFTS
    MCLAUGHLIN, PR
    BERMAN, ND
    MORTON, BC
    SCHWARTZ, L
    MORCH, JE
    AMERICAN HEART JOURNAL, 1977, 93 (03) : 327 - 333