MICRO-PIXE QUANTIFICATION OF HISTOCHEMICAL REACTIONS

被引:1
|
作者
ROKITA, E
CICHOCKI, T
DIVOUX, S
GONSIOR, B
HOFERT, M
JARCZYK, L
STRZALKOWSKI, A
SYCH, M
机构
[1] RUHR UNIV BOCHUM,INST EXPTL PHYS 3,W-4630 BOCHUM,GERMANY
[2] NICHOLAS COPERNICUS MED ACAD,DEPT HISTOL,PL-31034 KRAKOW,POLAND
[3] NICHOLAS COPERNICUS MED ACAD,DEPT ANESTHESIOL & INTENS THERAPY,PL-31034 KRAKOW,POLAND
关键词
D O I
10.1016/0168-583X(90)90290-B
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The proton induced X-ray emission in combination with a proton microprobe (micro-PIXE) was used for the quantitative determination of a locally bound histochemical reaction end-product. The determination of proteoglycans (PG) content in the cartilage is described in detail. The cartilage from the femur and the skull of 17-19 days old embryos and from ribs of mature CBA strain mice was investigated. The 8 μm cryomicrotome sections, placed on a formvar backing, were incubated in colloidal iron or in alcian blue (dye molecule contains Cu) solutions. The determination of PG contents was made indirectly by assessment of the Fe or Cu concentrations. Differences in the PG contents were observed within all investigated cartilage types. The embryonal cartilage contains more PG than that obtained from mature animals. For the cartilage from the femur the highest content of PG was found in the mineralization front while fully formed bone trabeculae exhibited a PG level 10 times lower. In the case of intramembranaceous ossification the content of PG was also higher in the skull cartilage than in the loose connective tissue. On the basis of the performed studies some methodological conclusions can be drawn. For PG determination, the alcian blue method is more reliable than the colloidal iron technique. The review of the histochemical procedures which may be combined with the micro-PIXE method is also given. © 1990.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 50 条
  • [31] PIXE and micro-PIXE studies of ion release around endosseous implants in animals
    Egeni, GP
    Jaksic, M
    Moschini, G
    Passi, P
    Piattelli, A
    Rossi, P
    Rudello, V
    Tauro, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 : 289 - 293
  • [32] Lapis lazuli provenance study by means of micro-PIXE
    Re, Alessandro
    Lo Giudice, Alessandro
    Angelici, Debora
    Calusi, Silvia
    Giuntini, Lorenzo
    Massi, Mirko
    Pratesi, Giovanni
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (20): : 2373 - 2377
  • [33] Micro-PIXE studies on gallium incorporation in mineralized tissue
    Rokita, E
    Korbas, M
    Mutsaers, PHA
    Taton, G
    de Voigt, MJA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 529 - 532
  • [34] Micro-PIXE mapping of sodium and chlorine in selected seagrasses
    Przybylowicz, WJ
    Pineda, CA
    Barnabas, AD
    Mesjasz-Przybylowicz, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 150 (1-4): : 282 - 290
  • [35] Preliminary studies on applications of micro-PIXE to atmospheric aerosols
    Kasahara, M
    Ma, CJ
    Kamiya, T
    Sakai, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 : 622 - 627
  • [36] MICRO-PIXE MEASUREMENTS IN METEORITES AS A SOURCE OF NEW INFORMATION
    BAJT, S
    TRAXEL, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 54 (1-3): : 317 - 324
  • [37] MICRO-PIXE ANALYSIS OF SILICATE REFERENCE-STANDARDS
    CZAMANSKE, GK
    SISSON, TW
    CAMPBELL, JL
    TEESDALE, WJ
    [J]. AMERICAN MINERALOGIST, 1993, 78 (9-10) : 893 - 903
  • [38] ACCURACY OF THICK-TARGET MICRO-PIXE ANALYSIS
    CAMPBELL, JL
    TEESDALE, WJ
    WANG, JX
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 50 (1-4): : 189 - 196
  • [39] Analysis of geological samples by the micro-PIXE facility at KFUPM
    M. Ahmed
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2005, 265 : 39 - 45
  • [40] MICRO-PIXE ANALYSES OF THICK FROZEN LENSES WITH CATARACTS
    KOYAMAITO, H
    WADA, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 75 (1-4): : 518 - 520