MEASURING LOADS WITH THE AID OF AN INSTRUMENTED INTERNAL SPINAL FIXATION DEVICE

被引:3
|
作者
ROHLMANN, A
EICK, O
BERGMANN, G
GRAICHEN, F
机构
[1] Orthopädische Klinik und Poliklinik der Freien Universität im Oskar-Helene-Heim, Berlin, Biomechanik-Labor
来源
BIOMEDIZINISCHE TECHNIK | 1993年 / 38卷 / 10期
关键词
INTERNATIONAL FIXATION DEVICE; LOAD MEASURING; SPINAL COLUMN;
D O I
10.1515/bmte.1993.38.10.255
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Little is known about the loads acting on internal spinal fixation devices. The effective forces and moments associated with different external loads have now been measured using instrumented implants. Measurements were obtained in intact cadaver spines and following vertebrectomy. The influence of the implant itself on the distribution of the loads was also investigated. It was found that the implants are not loaded symmetrically. Following vertebrectomy, the forces acting on the fixation device are significantly higher than in the case of an intact spine.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [41] Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices
    Biomechanics Laboratory, Department of Orthopaedic Surgery, Orthoped. Hosp. Free Univ. of Berlin, Clayallee 229, 14195 Berlin, Germany
    J. Biomech., 7 (727-731):
  • [42] Modification of the Leeb Impact Device for Measuring Hardness by the Dynamic Instrumented Indentation Method
    Aleksander, Umanskii
    Kirill, Gogolinskii
    Vladimir, Syasko
    Artem, Golev
    INVENTIONS, 2022, 7 (01)
  • [43] THE VALIDITY AND RELIABILITY OF A NEW INSTRUMENTED DEVICE FOR MEASURING ANKLE DORSIFLEXION RANGE OF MOTION
    Calatayud, Joaquin
    Martin, Fernando
    Gargallo, Pedro
    Garcia-Redondo, Jessica
    Carlos, Juan
    Marin, Pedro J.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2015, 10 (02): : 197 - 202
  • [44] Measuring Method of the Internal Temperature of UHV DC Voltage Measuring Device
    Xie Tingting
    Yang Zhongzhou
    Feng Jianhua
    Zheng Wei
    Wang Shan
    2018 3RD ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2018), 2018, 366
  • [45] Loads on internal spinal fixators measured in different body positions
    A. Rohlmann
    G. Bergmann
    F. Graichen
    European Spine Journal, 1999, 8 : 354 - 359
  • [46] Loads on internal spinal fixators measured in different body positions
    Rohlmann, A
    Bergmann, G
    Graichen, F
    EUROPEAN SPINE JOURNAL, 1999, 8 (05) : 354 - 359
  • [47] MEASURING METHOD FOR INVIVO MEASUREMENTS IN IMPLANTS FOR FIXATION OF SPINAL FRACTURES
    WILKE, HJ
    DURSELEN, L
    CLAES, L
    WORSDORFER, O
    BIOMEDIZINISCHE TECHNIK, 1992, 37 (04): : 78 - 85
  • [48] Measuring spinal motion in rowers: the use of an electromagnetic device
    Bull, AMJ
    McGregor, AH
    CLINICAL BIOMECHANICS, 2000, 15 (10) : 772 - 776
  • [49] Spinal fixation device: A 6-year postimplantation study
    Mohanty, M
    Baby, S
    Menon, KV
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2003, 18 (02) : 109 - 121
  • [50] USE OF INTERNAL-FIXATION IN THORACOLUMBAR SPINAL-INJURIES
    MAYER, H
    SCHAAF, D
    KUDERNATSCH, M
    CHIRURG, 1992, 63 (11): : 944 - 949