Loads on internal spinal fixators measured in different body positions

被引:64
|
作者
Rohlmann, A [1 ]
Bergmann, G [1 ]
Graichen, F [1 ]
机构
[1] Oskar Helene Heim Biomech Lab, D-14195 Berlin, Germany
关键词
internal spinal fixator; load measurement; body position; telemetry; spine;
D O I
10.1007/s005860050187
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Telemeterized internal spinal fixation devices were implanted in ten patients. The loads acting on the fixators were compared for different body positions, including standing, sitting, and lying in a supine, prone, and lateral position. Implant loads differed considerably from patient to patient depending, for example, on the indication for surgery and the surgical procedure. They were altered by anterior interbody fusion. Mostly, only small differences in implant loads were found for the various lying positions. Flexion bending moments were significantly higher in upright than in lying body positions. Loads on the fixators were not higher for sitting than for standing, patients who have undergone mono- or bisegmental spine stabilization should therefore be allowed to sit as soon as they can leave the bed.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 50 条
  • [1] Loads on internal spinal fixators measured in different body positions
    A. Rohlmann
    G. Bergmann
    F. Graichen
    European Spine Journal, 1999, 8 : 354 - 359
  • [2] Influence of load carrying on loads in internal spinal fixators
    Rohlmann, A
    Graichen, F
    Bergmann, G
    JOURNAL OF BIOMECHANICS, 2000, 33 (09) : 1099 - 1104
  • [3] Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises
    Rohlmann, A
    Claes, LE
    Bergmann, G
    Graichen, F
    Neef, P
    Wilke, HJ
    ERGONOMICS, 2001, 44 (08) : 781 - 794
  • [4] Comparison of loads on internal spinal fixation devices measured in vitro and in vivo
    Rohlmann, A
    Bergmann, G
    Graichen, F
    Weber, U
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (06) : 539 - 546
  • [5] History of internal fixators. The subsequent importance for spinal surgery
    Dick, W.
    Rickert, M.
    UNFALLCHIRURG, 2015, 118 : S66 - S72
  • [6] Loads on a spinal implant measured in vivo during whole-body vibration
    Rohlmann, Antonius
    Hinz, Barbara
    Bluethner, Ralph
    Graichen, Friedmar
    Bergmann, Georg
    EUROPEAN SPINE JOURNAL, 2010, 19 (07) : 1129 - 1135
  • [7] Loads on a spinal implant measured in vivo during whole-body vibration
    Antonius Rohlmann
    Barbara Hinz
    Ralph Blüthner
    Friedmar Graichen
    Georg Bergmann
    European Spine Journal, 2010, 19 : 1129 - 1135
  • [8] External, Internal, Perceived Training Loads and Their Relationships in Youth Basketball Players Across Different Positions
    Sansone, Pierpaolo
    Ceravolo, Alessandro
    Tessitore, Antonio
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2022, 17 (02) : 249 - 255
  • [9] Loads on internal spinal fixation devices
    Rohlmann, A
    Bergmann, G
    Graichen, F
    Weber, U
    ORTHOPADE, 1999, 28 (05): : 451 - 457
  • [10] Loads on an internal spinal fixator during sitting
    Rohlmann, A.
    Graichen, F.
    Bergmann, G.
    Journal of Biomechanics, 2001, 34 (SUPPL. 1)