Loads on internal spinal fixators measured in different body positions

被引:64
|
作者
Rohlmann, A [1 ]
Bergmann, G [1 ]
Graichen, F [1 ]
机构
[1] Oskar Helene Heim Biomech Lab, D-14195 Berlin, Germany
关键词
internal spinal fixator; load measurement; body position; telemetry; spine;
D O I
10.1007/s005860050187
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Telemeterized internal spinal fixation devices were implanted in ten patients. The loads acting on the fixators were compared for different body positions, including standing, sitting, and lying in a supine, prone, and lateral position. Implant loads differed considerably from patient to patient depending, for example, on the indication for surgery and the surgical procedure. They were altered by anterior interbody fusion. Mostly, only small differences in implant loads were found for the various lying positions. Flexion bending moments were significantly higher in upright than in lying body positions. Loads on the fixators were not higher for sitting than for standing, patients who have undergone mono- or bisegmental spine stabilization should therefore be allowed to sit as soon as they can leave the bed.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 50 条
  • [21] Change of the Lymphatic Diameter in Different Body Positions
    Hara, Hisako
    Mihara, Makoto
    LYMPHATIC RESEARCH AND BIOLOGY, 2021, 19 (03) : 249 - 255
  • [22] AIRWAY SIZE CHANGES IN DIFFERENT BODY POSITIONS
    PAE, E
    LOWE, A
    FLEETHAM, J
    PRICE, C
    TSUCHIYA, M
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 337 - 337
  • [23] INERTIAL CHARACTERISTICS OF HUMAN BODY IN DIFFERENT POSITIONS
    COBLENTZ, A
    IGNAZI, G
    TRAVAIL HUMAIN, 1971, 34 (02): : 363 - &
  • [24] Lumbar spinal loads vary with body height and weight
    Han, Kap-Soo
    Rohlmann, Antonius
    Zander, Thomas
    Taylor, William R.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (07) : 969 - 977
  • [25] Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices
    Calisse, J
    Rohlmann, A
    Bergmann, G
    JOURNAL OF BIOMECHANICS, 1999, 32 (07) : 727 - 731
  • [26] Different Arm Positions and the Shape of the Thoracic Spine Can Explain Contradictory Results in the Literature About Spinal Loads for Sitting and Standing
    Dreischarf, Marcel
    Bergmann, Georg
    Wilke, Hans-Joachim
    Rohlmann, Antonius
    SPINE, 2010, 35 (22) : 2015 - 2021
  • [27] Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices
    Biomechanics Laboratory, Department of Orthopaedic Surgery, Orthoped. Hosp. Free Univ. of Berlin, Clayallee 229, 14195 Berlin, Germany
    J. Biomech., 7 (727-731):
  • [28] Loads on a telemeterized vertebral body replacement measured in two patients
    Rohlmann, Antonius
    Graichen, Friedmar
    Kayser, Ralph
    Bender, Alwina
    Bergmann, Georg
    SPINE, 2008, 33 (11) : 1170 - 1179
  • [29] Loads on a vertebral body replacement during locomotion measured in vivo
    Rohlmann, A.
    Dreischarf, M.
    Zander, T.
    Graichen, F.
    Bergmann, G.
    GAIT & POSTURE, 2014, 39 (02) : 750 - 755
  • [30] MEASURING LOADS WITH THE AID OF AN INSTRUMENTED INTERNAL SPINAL FIXATION DEVICE
    ROHLMANN, A
    EICK, O
    BERGMANN, G
    GRAICHEN, F
    BIOMEDIZINISCHE TECHNIK, 1993, 38 (10): : 255 - 259