MEASURING LOADS WITH THE AID OF AN INSTRUMENTED INTERNAL SPINAL FIXATION DEVICE

被引:3
|
作者
ROHLMANN, A
EICK, O
BERGMANN, G
GRAICHEN, F
机构
[1] Orthopädische Klinik und Poliklinik der Freien Universität im Oskar-Helene-Heim, Berlin, Biomechanik-Labor
来源
BIOMEDIZINISCHE TECHNIK | 1993年 / 38卷 / 10期
关键词
INTERNATIONAL FIXATION DEVICE; LOAD MEASURING; SPINAL COLUMN;
D O I
10.1515/bmte.1993.38.10.255
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Little is known about the loads acting on internal spinal fixation devices. The effective forces and moments associated with different external loads have now been measured using instrumented implants. Measurements were obtained in intact cadaver spines and following vertebrectomy. The influence of the implant itself on the distribution of the loads was also investigated. It was found that the implants are not loaded symmetrically. Following vertebrectomy, the forces acting on the fixation device are significantly higher than in the case of an intact spine.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] IN-VITRO MEASUREMENT OF THE LOADS USING AN INSTRUMENTED SPINAL FIXATION DEVICE
    ROHLMANN, A
    EICK, O
    BERGMANN, G
    GRAICHEN, F
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1995, 133 (02): : 136 - 140
  • [2] Loads on an internal spinal fixation device during sitting
    Rohlmann, A
    Arntz, U
    Graichen, F
    Bergmann, G
    JOURNAL OF BIOMECHANICS, 2001, 34 (08) : 989 - 993
  • [3] Loads on an internal spinal fixation device during walking
    Rohlmann, A
    Bergmann, G
    Graichen, F
    JOURNAL OF BIOMECHANICS, 1997, 30 (01) : 41 - 47
  • [4] Loads on an internal spinal fixation device during physical therapy
    Rohlmann, A
    Graichen, F
    Bergmann, G
    PHYSICAL THERAPY, 2002, 82 (01): : 44 - 52
  • [5] Loads on internal spinal fixation devices
    Rohlmann, A
    Bergmann, G
    Graichen, F
    Weber, U
    ORTHOPADE, 1999, 28 (05): : 451 - 457
  • [6] In vitro load measurement using an instrumented spinal fixation device
    Rohlmann, A
    Riley, LH
    Bergmann, G
    Graichen, F
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (06) : 485 - 488
  • [7] THE INSTRUMENTED EXTERNAL FIXATION AS AN DEVICE OF MEASURING THE EXTERNAL FRACTURE-HEALING
    MULLER, KH
    ZENTRALBLATT FUR CHIRURGIE, 1984, 109 (14): : 929 - 937
  • [8] Influence of muscle forces on loads in internal spinal fixation devices
    Rohlmann, A
    Bergmann, G
    Graichen, F
    Mayer, HM
    SPINE, 1998, 23 (05) : 537 - 542
  • [9] Braces do not reduce loads on internal spinal fixation devices
    Rohlmann, A
    Bergmann, G
    Graichen, F
    Neff, G
    CLINICAL BIOMECHANICS, 1999, 14 (02) : 97 - 102
  • [10] Comparison of loads on internal spinal fixation devices measured in vitro and in vivo
    Rohlmann, A
    Bergmann, G
    Graichen, F
    Weber, U
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (06) : 539 - 546