EMPIRICAL INVESTIGATION OF INDOOR ENVIRONMENTAL QUALITY (IEQ) PERFORMANCE IN HOSPITAL BUILDINGS IN NIGERIA

被引:0
|
作者
Nimlyat, Pontip Stephen [1 ,2 ]
Kandar, Mohd Zin [1 ]
Sediadi, Eka [1 ]
机构
[1] Univ Teknol Malaysia, Fac Built Environm, Dept Architecture, Johor Baharu 81310, Johor, Malaysia
[2] Univ Jos, Dept Architecture, Jos, Nigeria
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 14期
关键词
Indoor; environmental quality; measurement; parameters; hospital buildings;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study investigates and summarises the results of physical measurement of the indoor environmental quality (IEQ) in hospital building wards in Plateau State, Nigeria comparing two hospital settings. The results indicate that the mean indoor air temperature in the case study hospital ward buildings exceeded the range of 23-26(o)C as recommended by international standards. The temperature levels in the teaching hospital ward buildings were relatively lower than what was obtained in the specialist hospital whose ward buildings lack proper ventilation. The amount of daylight requirement on an average were below 300Lux in the specialist hospital whose facade orientation and window-wall-ratio (WWR) could not allow for maximum sunlight penetration, while it was above 300Lux in the teaching hospital. However, the sound intensity level in both hospital ward buildings ranged between 52.7dBA and 71.3dBA. This study therefore recommend that, hospital building design or retrofitting should employed common strategies towards increasing ventilation and daylight with minimal energy consumption.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 50 条
  • [31] Indoor Environmental Quality Performance Approaches: Trending IAQ to IEQ to COVID-19 Extended Abstract
    Miller, Shelly
    McQueen, Matthew
    Horn, Shannon
    Lockhart, Timothy
    IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [32] Indoor environmental quality (IEQ) of LEED-certified home: Importance-performance analysis (IPA)
    Lee, Eunsil
    BUILDING AND ENVIRONMENT, 2019, 149 : 571 - 581
  • [33] Analyzing the impact of indoor environmental quality on physiological responses and work performance: Implications for IEQ control strategies
    Oh, Donggeun
    Kim, Jimin
    Kim, Handon
    Jang, Hyounseung
    Hong, Taehoon
    An, Jongbaek
    BUILDING AND ENVIRONMENT, 2023, 244
  • [34] Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms
    Lee, M. C.
    Mui, K. W.
    Wong, L. T.
    Chan, W. Y.
    Lee, E. W. M.
    Cheung, C. T.
    BUILDING AND ENVIRONMENT, 2012, 49 : 238 - 244
  • [35] Novel Technologies to Enhance Energy Performance and Indoor Environmental Quality of Buildings
    Cannavale, Alessandro
    Martellotta, Francesco
    Fiorito, Francesco
    BUILDINGS, 2021, 11 (07)
  • [36] Impacts of Indoor Environmental Quality (IEQ) Elements on Residential Property Market: A Review
    Kasim, Asmma' Che
    Rahman, Megat Mohd Ghazali Megat Abdul
    Raid, Maryanti Mohd
    JURNAL TEKNOLOGI, 2015, 73 (05):
  • [37] Ten Questions Concerning Indoor Environmental Quality (IEQ) Models: The Development and Applications
    Zhang, Dadi
    Mui, Kwok-Wai
    Wong, Ling-Tim
    APPLIED SCIENCES-BASEL, 2023, 13 (05):
  • [38] Indoor environmental quality (IEQ) assessment of Nigerian university libraries: A pilot study
    Akanmu W.P.
    Nunayon S.S.
    Eboson U.C.
    Energy and Built Environment, 2021, 2 (03): : 302 - 314
  • [39] IEQ-Compass - A tool for holistic evaluation of potential indoor environmental quality
    Larsen, Tine Steen
    Rohde, Lasse
    Jonsson, Kim Trangbaek
    Rasmussen, Birgit
    Jensen, Rasmus Lund
    Knudsen, Henrik N.
    Witterseh, Thomas
    Beko, Gabriel
    BUILDING AND ENVIRONMENT, 2020, 172
  • [40] An Indoor Environmental Quality (IEQ) assessment of a partially-retrofitted university building
    Zuhaib, Sheikh
    Manton, Richard
    Griffin, Corey
    Hajdukiewicz, Magdalena
    Keane, Marcus M.
    Goggins, Jamie
    BUILDING AND ENVIRONMENT, 2018, 139 : 69 - 85