PAB - A NEWLY DESIGNED POTENTIOMETRIC ALTERNATING BIOSENSOR SYSTEM

被引:28
|
作者
ADAMI, M
SARTORE, M
NICOLINI, C
机构
[1] CONSORZIO RIC IND AVANZATA,TECHNOBIOCHIP,I-57030 MARCIANA,ITALY
[2] UNIV GENOA,INST BIOPHYS,I-16153 GENOA,ITALY
来源
BIOSENSORS & BIOELECTRONICS | 1995年 / 10卷 / 1-2期
关键词
PAB; LAPS; POTENTIOMETRIC SENSORS; CELL BIOSENSOR; ENZYME- AND IMMUNO-SENSOR;
D O I
10.1016/0956-5663(95)96803-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A complete potentiometric alternating biosensor system (PAB) is described which utilizes a newly developed transducer based on the light addressable chemical sensor (LAPS) technology, following detailed theoretical optimizations of the relevant physical parameters. Our device, entirely designed and realized 'in house', combines measuring chambers with specific electronic cards and the related software programs; the system is completely automated and driven by a personal computer. The electronics was designed in order to obtain a good general signal-to-noise ratio, hence ensuring reproducible results. The software package consists of low-level programs (written both in C and in Assembler) to interact with the data acquisition and controlling cards, and of high-level programs (written in C) to get, display, save and print data files, and to present a suitable user interface. A very important peculiarity of our system is the possibility of connecting different measuring chambers to the same device. This allows the user to perform a wide variety of experiments, utilizing different biological elements, by simply changing the reaction chamber and selecting the appropriate acquisition software. The system has been shown to operate with living cells as well as with enzymes and antibodies. In addition, a particular chamber containing a gold-evaporated transducer can be connected to the main system, allowing redox potential measurements. The system utilizes a fast information recovery from the transducer output signal, and can acquire quantitative data every few fractions of a second. This feature can be utilized to monitor fast acidification or redox processes.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 50 条
  • [41] Improved performance of the potentiometric biosensor for the determination of creatinine
    Dallerup Rasmussen, Claus
    Andersen, Jens E. T.
    Zachau-Christiansen, Birgit
    ANALYTICAL LETTERS, 2007, 40 (01) : 39 - 52
  • [42] Urease immobilized potentiometric biosensor for determination of urea
    Sihombing, Kawan
    Tamba, Monica Chrisdayanti
    Marbun, Winry Sulistiani
    Situmorang, Manihar
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2018, 57 (02): : 175 - 180
  • [43] Enhancement of Signal-to-Noise Ratio for Serotonin Detection with Well-Designed Nanofilter-Coated Potentiometric Electrochemical Biosensor
    Nishitani, Shoichi
    Sakata, Toshiya
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (13) : 14761 - 14769
  • [44] Development of potentiometric biosensor for diagnosis of prostate cancer
    Altunkok, Nazire
    Unluer, Ozlem Bicen
    Ozkutuk, Ebru Birlik
    Ersoz, Arzu
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2021, 263
  • [45] The potentiometric biosensor based on polyaniline semiconductor films
    Karyakin, AA
    Bobrova, OA
    Karyakina, EE
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 1996, 32 (08) : 939 - 942
  • [46] Potentiometric enzyme biosensor modified with gold nanoparticles
    Shkotova Lyudmyla
    Zinchenko Olena
    Arkhypova Valentyna
    Dzyadevych Sergiy
    Applied Nanoscience, 2023, 13 : 5133 - 5138
  • [47] LIGHT ADDRESSABLE POTENTIOMETRIC BIOSENSOR FOR THE DETECTION OF ANTICHOLINESTERASES
    ROGERS, KR
    FOLEY, M
    ALTER, S
    KOGA, P
    ELDEFRAWI, M
    ANALYTICAL LETTERS, 1991, 24 (02) : 191 - 198
  • [48] A new potentiometric ammonium electrode for biosensor construction
    Karakus, Emine
    Pekyardimci, Sule
    Kilic, Esma
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (05): : 523 - 534
  • [49] POTENTIOMETRIC BIOSENSOR IN DOUBLE MATRIX MEMBRANE TECHNOLOGY
    EGGENSTEIN, C
    BORCHARDT, M
    DUMSCHAT, C
    GRUNDIG, B
    CAMMANN, K
    SPENER, F
    KNOLL, M
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7): : 595 - 600
  • [50] Potentiometric enzyme biosensor modified with gold nanoparticles
    Lyudmyla, Shkotova
    Olena, Zinchenko
    Valentyna, Arkhypova
    Sergiy, Dzyadevych
    APPLIED NANOSCIENCE, 2022, 13 (7) : 5133 - 5138