PAB - A NEWLY DESIGNED POTENTIOMETRIC ALTERNATING BIOSENSOR SYSTEM

被引:28
|
作者
ADAMI, M
SARTORE, M
NICOLINI, C
机构
[1] CONSORZIO RIC IND AVANZATA,TECHNOBIOCHIP,I-57030 MARCIANA,ITALY
[2] UNIV GENOA,INST BIOPHYS,I-16153 GENOA,ITALY
来源
BIOSENSORS & BIOELECTRONICS | 1995年 / 10卷 / 1-2期
关键词
PAB; LAPS; POTENTIOMETRIC SENSORS; CELL BIOSENSOR; ENZYME- AND IMMUNO-SENSOR;
D O I
10.1016/0956-5663(95)96803-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A complete potentiometric alternating biosensor system (PAB) is described which utilizes a newly developed transducer based on the light addressable chemical sensor (LAPS) technology, following detailed theoretical optimizations of the relevant physical parameters. Our device, entirely designed and realized 'in house', combines measuring chambers with specific electronic cards and the related software programs; the system is completely automated and driven by a personal computer. The electronics was designed in order to obtain a good general signal-to-noise ratio, hence ensuring reproducible results. The software package consists of low-level programs (written both in C and in Assembler) to interact with the data acquisition and controlling cards, and of high-level programs (written in C) to get, display, save and print data files, and to present a suitable user interface. A very important peculiarity of our system is the possibility of connecting different measuring chambers to the same device. This allows the user to perform a wide variety of experiments, utilizing different biological elements, by simply changing the reaction chamber and selecting the appropriate acquisition software. The system has been shown to operate with living cells as well as with enzymes and antibodies. In addition, a particular chamber containing a gold-evaporated transducer can be connected to the main system, allowing redox potential measurements. The system utilizes a fast information recovery from the transducer output signal, and can acquire quantitative data every few fractions of a second. This feature can be utilized to monitor fast acidification or redox processes.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 50 条
  • [21] Potentiometric biosensor for urea determination in milk
    Trivedi, U. B.
    Lakshminarayana, D.
    Kothari, I. L.
    Patel, N. G.
    Kapse, H. N.
    Makhija, K. K.
    Patel, R. B.
    Panchal, C. J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) : 260 - 266
  • [22] The Stability Analysis of Potentiometric Urea Biosensor Under Microfluidic System and Remote Measurement
    Kuo, Po-Yu
    Dong, Zhe-Xin
    Chen, Yung-Yu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [23] Dual amperometric-potentiometric biosensor detection system for monitoring organophosphorus neurotoxins
    Wang, J
    Krause, R
    Block, K
    Musameh, M
    Mulchandani, A
    Mulchandani, P
    Chen, W
    Schöning, MJ
    ANALYTICA CHIMICA ACTA, 2002, 469 (02) : 197 - 203
  • [24] Comparison of a potentiometric and a micromechanical triglyceride biosensor
    Fernandez, Renny Edwin
    Hareesh, Vemulachedu
    Bhattacharya, Enakshi
    Chadha, Anju
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1276 - 1280
  • [25] NEWLY DEVELOPED MULTICOMPONENT PIEZOCERAMIC SYSTEM FOR ALTERNATING PRESSURE SENSORS
    GRIDNEV, SA
    PAVLOVA, NG
    GORBATENKO, VV
    SHUVALOV, LA
    FERROELECTRICS, 1992, 134 (1-4) : 53 - 57
  • [26] Fast response potentiometric acetylcholine biosensor
    Gyurcsányi, RE
    Vágföldi, Z
    Tóth, K
    Nagy, G
    ELECTROANALYSIS, 1999, 11 (10-11) : 712 - 718
  • [27] A SIMPLE DISPOSABLE POTENTIOMETRIC BIOSENSOR FOR PESTICIDES
    TROJANOWICZ, M
    HITCHMAN, ML
    CHEMIA ANALITYCZNA, 1995, 40 (04): : 609 - 617
  • [28] Fast response potentiometric acetylcholine biosensor
    Inst. for Gen. and Analyt. Chemistry, Technical University of Budapest, Szt. Gellért tér 4, H-1111 Budapest, Hungary
    不详
    Electroanalysis, 10-11 (712-718):
  • [29] Performance of a newly designed continuous soot monitoring system (COSMOS)
    Miyazaki, Yuzo
    Kondo, Yutaka
    Sahu, Lokesh K.
    Imaru, Junichi
    Fukushima, Nobuhiko
    Kano, Minoru
    JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (10): : 1195 - 1201
  • [30] NEWLY DESIGNED STERILIZATION SYSTEM FOR THE OPERATING MICROSCOPE - A TECHNICAL NOTE
    MATSUO, K
    KYOSHIMA, K
    SUGITA, K