MAGNETIC-RESONANCE-IMAGING OF RADIATION-DOSE DISTRIBUTIONS USING A POLYMER-GEL DOSIMETER

被引:352
|
作者
MARYANSKI, MJ
SCHULZ, RJ
IBBOTT, GS
GATENBY, JC
XIE, J
HORTON, D
GORE, JC
机构
[1] YALE UNIV,DEPT THERAPEUT RADIOL,NEW HAVEN,CT 06510
[2] UNIV LONDON KINGS COLL,DEPT MED ENGN & PHYS,LONDON WC2R 2LS,ENGLAND
[3] YALE UNIV,DEPT PHYS,NEW HAVEN,CT 06510
[4] YALE UNIV,YALE COLL,NEW HAVEN,CT 06510
[5] MGS RES INC,NEW HAVEN,CT 06511
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 09期
关键词
D O I
10.1088/0031-9155/39/9/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new formulation of a tissue-equivalent polymer-gel dosimeter for the measurement of three-dimensional dose distributions of ionizing radiation has been developed. It is composed of aqueous gelatin infused with acrylamide and N, N'-methylene-bisacrylamide monomers, and made hypoxic by nitrogen saturation. Irradiation of the gel, referred to as BANG, causes localized polymerization of the monomers, which, in turn, reduces the transverse NMR relaxation times of water protons. The dose dependence of the NMR transverse relaxation rate, R(2), is reproducible (less than 2% variation) and is linear up to about 8 Gy, with a slope of 0.25 s(-1)Gy(-1) at 1.5 T. Magnetic resonance imaging may be used to obtain accurate three-dimensional dose distributions with high spatial resolution. Since the radiation-induced polymers do not diffuse through the gelatin matrix, the dose distributions recorded by BANG gels are stable for long periods of time, and may be used to measure low-activity radioactive sources. Since the light-scattering properties of the polymerized regions are different from those of the clear, non-irradiated regions, the dose distributions are visible, and their optical densities are dependent on dose.
引用
收藏
页码:1437 / 1455
页数:19
相关论文
共 50 条
  • [1] Radiation dose distributions using a polymer gel dosimeter: A comparison of analyses using magnetic resonance imaging and laser optical scanning
    Witten, M
    Xu, Y
    Maryanski, M
    Reich, D
    Wuu, C
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1207 - 1207
  • [2] Measurement of relative dose distributions in stereotactic radiosurgery by the polymer-gel dosimeter
    Novotny, J
    Spevácek, V
    Hrbácek, J
    Judas, L
    Novotny, J
    Dvorák, P
    Tlachácová, D
    Schmitt, M
    Tintera, J
    Vymazal, J
    Cechák, T
    Michálek, J
    Prádny, M
    Liscák, R
    [J]. RADIOSUGERY, VOL 5, 2004, 5 : 225 - 235
  • [3] Application of polymer-gel dosimeter for evaluation of relative dose distributions in stereotactic radiotherapy
    Novotny, JJ
    Spevacek, V
    Dvorak, P
    Novotny, J
    Hrbacek, J
    Tintera, J
    Vymazal, J
    Cechak, T
    Michalek, J
    Vacik, J
    Liscak, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S51 - S51
  • [4] Temperature dependence of polymer-gel dosimeter nuclear magnetic resonance response
    Spevacek, V
    Novotny, J
    Dvorak, P
    Novotny, J
    Vymazal, J
    Cechak, T
    [J]. MEDICAL PHYSICS, 2001, 28 (11) : 2370 - 2378
  • [5] MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING
    GORE, JC
    KANG, YS
    SCHULZ, RJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10): : 1189 - 1197
  • [6] Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging
    Venning, AJ
    Hill, B
    Brindha, S
    Healy, BJ
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3875 - 3888
  • [7] An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
    Abtahi, S. M.
    Khalilabadi, R. Jafari
    Aftabi, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (02): : 185 - 196
  • [8] Characterization of Improved PASSAG Polymer Gel Dosimeter Using Magnetic Resonance Imaging
    Masoumeh Dorri Giv
    Mehrsa Majdaeen
    Masoumeh Yadollahi
    Samira Abbaspour
    Masoud Sadrnia
    Meysam Haghighi Borujeni
    Gholamreza Ataei
    Razzagh Abedi-Firouzjah
    [J]. Applied Magnetic Resonance, 2022, 53 : 441 - 455
  • [9] Characterization of Improved PASSAG Polymer Gel Dosimeter Using Magnetic Resonance Imaging
    Giv, Masoumeh Dorri
    Majdaeen, Mehrsa
    Yadollahi, Masoumeh
    Abbaspour, Samira
    Sadrnia, Masoud
    Borujeni, Meysam Haghighi
    Ataei, Gholamreza
    Abedi-Firouzjah, Razzagh
    [J]. APPLIED MAGNETIC RESONANCE, 2022, 53 (02) : 441 - 455
  • [10] Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging
    Azadbakht, B.
    Zahmatkesh, M. H.
    Hadad, K.
    Bagheri, S.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2008, 6 (02): : 85 - 89