MAGNETIC-RESONANCE-IMAGING OF RADIATION-DOSE DISTRIBUTIONS USING A POLYMER-GEL DOSIMETER

被引:352
|
作者
MARYANSKI, MJ
SCHULZ, RJ
IBBOTT, GS
GATENBY, JC
XIE, J
HORTON, D
GORE, JC
机构
[1] YALE UNIV,DEPT THERAPEUT RADIOL,NEW HAVEN,CT 06510
[2] UNIV LONDON KINGS COLL,DEPT MED ENGN & PHYS,LONDON WC2R 2LS,ENGLAND
[3] YALE UNIV,DEPT PHYS,NEW HAVEN,CT 06510
[4] YALE UNIV,YALE COLL,NEW HAVEN,CT 06510
[5] MGS RES INC,NEW HAVEN,CT 06511
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1994年 / 39卷 / 09期
关键词
D O I
10.1088/0031-9155/39/9/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new formulation of a tissue-equivalent polymer-gel dosimeter for the measurement of three-dimensional dose distributions of ionizing radiation has been developed. It is composed of aqueous gelatin infused with acrylamide and N, N'-methylene-bisacrylamide monomers, and made hypoxic by nitrogen saturation. Irradiation of the gel, referred to as BANG, causes localized polymerization of the monomers, which, in turn, reduces the transverse NMR relaxation times of water protons. The dose dependence of the NMR transverse relaxation rate, R(2), is reproducible (less than 2% variation) and is linear up to about 8 Gy, with a slope of 0.25 s(-1)Gy(-1) at 1.5 T. Magnetic resonance imaging may be used to obtain accurate three-dimensional dose distributions with high spatial resolution. Since the radiation-induced polymers do not diffuse through the gelatin matrix, the dose distributions recorded by BANG gels are stable for long periods of time, and may be used to measure low-activity radioactive sources. Since the light-scattering properties of the polymerized regions are different from those of the clear, non-irradiated regions, the dose distributions are visible, and their optical densities are dependent on dose.
引用
下载
收藏
页码:1437 / 1455
页数:19
相关论文
共 50 条
  • [31] Detection of the radionuclide rhenium-188 radiation dose using a normoxic polymer gel dosimeter
    Liu Ming-Hung
    Yu Bi-Wei
    Chang Tien-Hsin
    Hsieh Bor-Tsung
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2013, 56 : S271 - S271
  • [32] Ultrasound tomography imaging of radiation dose distributions in polymer gel dosimeters: Preliminary study
    Mather, ML
    Baldock, C
    MEDICAL PHYSICS, 2003, 30 (08) : 2140 - 2148
  • [33] ACQUISITION AND DISPLAY OF RADIATION-DOSE DISTRIBUTIONS USING MICROCOMPUTER TECHNOLOGY
    ANTOLAK, J
    MAH, E
    BATTISTA, JJ
    SCRIMGER, JW
    MEDICAL PHYSICS, 1988, 15 (06) : 924 - 929
  • [34] THE QUESTION OF DOSE FOR GADOLINIUM CHELATES IN MAGNETIC-RESONANCE-IMAGING
    RUNGE, VM
    KIRSCH, JE
    WELLS, JW
    DUNWORTH, JN
    WOOLFOLK, CE
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S154 - S156
  • [35] MAGNETIC-RESONANCE-IMAGING OF RADIATION-INJURY TO THE BRAIN
    CURNES, JT
    LASTER, DW
    BALL, MR
    MOODY, DM
    WITCOFSKI, RL
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (03) : 389 - 394
  • [36] DETERMINING CURRENT DISTRIBUTIONS FOR RF RESONATORS IN MAGNETIC-RESONANCE-IMAGING
    FORBES, LK
    CROZIER, S
    DODDRELL, DM
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (03) : 284 - 292
  • [37] Three-dimensional dose distributions in a heterogeneous phantom measured by polymer gel dosimeter
    Watanabe, Y
    Perera, G
    Mooij, R
    Maryanski, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1371 - 1371
  • [38] Enhancement of Dose Response and Nuclear Magnetic Resonance Image of PAGAT Polymer Gel Dosimeter by Adding Silver Nanoparticles
    Sabbaghizadeh, Rahim
    Shamsudin, Roslinda
    Deyhimihaghighi, Najmeh
    Sedghi, Arman
    PLOS ONE, 2017, 12 (01):
  • [39] A TECHNIQUE FOR VELOCITY IMAGING USING MAGNETIC-RESONANCE-IMAGING
    RIDGWAY, JP
    SMITH, MA
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 822 - 822
  • [40] Effect of lithium chloride inorganic salt on the performance of N-(Hydroxymethyl)acrylamide polymer-gel dosimeter in radiation therapy
    Molham M. Eyadeh
    Saja A. Smadi
    Khalid A. Rabaeh
    Ammar A. Oglat
    Kevin R. Diamond
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 330 : 1255 - 1261