Measurement of relative dose distributions in stereotactic radiosurgery by the polymer-gel dosimeter

被引:0
|
作者
Novotny, J [1 ]
Spevácek, V [1 ]
Hrbácek, J [1 ]
Judas, L [1 ]
Novotny, J [1 ]
Dvorák, P [1 ]
Tlachácová, D [1 ]
Schmitt, M [1 ]
Tintera, J [1 ]
Vymazal, J [1 ]
Cechák, T [1 ]
Michálek, J [1 ]
Prádny, M [1 ]
Liscák, R [1 ]
机构
[1] Homolce Hosp, Dept Med Phys, Prague 15030 5, Czech Republic
来源
RADIOSUGERY, VOL 5 | 2004年 / 5卷
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study was to evaluate relative dose distributions in six various treatment plans (acoustic schwannoma, pituitary adenoma, meningioma, metastasis, Uveal melanoma and glaucoma) in the Leksell gamma knife stereotactic radiosurgery procedure by polymer-gel dosimeter. The presented experiment allowed a check of the entire stereotactic procedure including target stereotactic localization on MRI, treatment planning and irradiation. Relatively good agreement between dose profiles calculated and measured ill a special head phantom by polymer-gel dosimeter was observed. The maximum observed deviation in the spatial position of the center of measured and calculated dose profiles was 0.9 mm (median 0.3). Maximum observed difference in FWHM of measured and calculated profiles was 3.0 mm (median 1.4). No significant difference was observed in deviations between calculated and measured dose profiles related to different treatments simulated in this experiment. The use of the polymer-gel dosimeter for verification of stereotactic procedures has some unique advantages compared to other dosimetric systems which can be summarized as follows: (1) the dosimeter itself is tissue equivalent, (2) three-dimensional dose distributions can be measured, and (3) the dosimeter allows simulation of the patient's procedures without any limitations. Copyright (C) 2004 S. Karger AG, Basel.
引用
下载
收藏
页码:225 / 235
页数:11
相关论文
共 50 条
  • [1] Application of polymer-gel dosimeter for evaluation of relative dose distributions in stereotactic radiotherapy
    Novotny, JJ
    Spevacek, V
    Dvorak, P
    Novotny, J
    Hrbacek, J
    Tintera, J
    Vymazal, J
    Cechak, T
    Michalek, J
    Vacik, J
    Liscak, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S51 - S51
  • [2] Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry
    Novotny, J
    Dvorak, P
    Spevacek, V
    Tintera, J
    Novotny, J
    Cechak, T
    Liscak, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1254 - 1254
  • [3] Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry
    Novotny, J
    Dvorák, P
    Spácek, V
    Tintera, J
    Novotny, J
    Cechák, T
    Liscák, R
    RADIOTHERAPY AND ONCOLOGY, 2002, 63 (02) : 223 - 230
  • [4] MAGNETIC-RESONANCE-IMAGING OF RADIATION-DOSE DISTRIBUTIONS USING A POLYMER-GEL DOSIMETER
    MARYANSKI, MJ
    SCHULZ, RJ
    IBBOTT, GS
    GATENBY, JC
    XIE, J
    HORTON, D
    GORE, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09): : 1437 - 1455
  • [5] Energy and dose rate dependence of BANG-2 polymer-gel dosimeter
    Novotny, J
    Spevacek, V
    Dvorak, P
    Novotny, J
    Cechak, T
    MEDICAL PHYSICS, 2001, 28 (11) : 2379 - 2386
  • [6] Modification of a polymer-gel dosimeter and application in HDR brachytherapy
    Spevacek, V
    Hrbacek, J
    Novotny, J
    Dvorak, P
    Novotny, J
    Cechak, T
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S87 - S87
  • [7] Spectrophotometric determination of the optimal wavelength for a polymer-gel dosimeter
    Chang, Kyung Hwan
    Lee, Suk
    Cao, Yuan Jie
    Shim, Jang Bo
    Lee, Jung Ae
    Yang, Dae Sik
    Park, Young Je
    Yoon, Won Sup
    Kim, Chul Yong
    Cho, Sam Ju
    Lee, Sang Hoon
    Kim, Woo Chul
    Min, Chul Kee
    Cho, Kwang Hwan
    Huh, Hyun Do
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (08) : 1194 - 1198
  • [8] Spectrophotometric determination of the optimal wavelength for a polymer-gel dosimeter
    Kyung Hwan Chang
    Suk Lee
    Yuan Jie Cao
    Jang Bo Shim
    Jung Ae Lee
    Dae Sik Yang
    Young Je Park
    Won Sup Yoon
    Chul Yong Kim
    Sam Ju Cho
    Sang Hoon Lee
    Woo Chul Kim
    Chul Kee Min
    Kwang Hwan Cho
    Hyun Do Huh
    Journal of the Korean Physical Society, 2013, 62 : 1194 - 1198
  • [9] Verification of three-dimensional IMRT dose distribution in the inhomogeneous media using a polymer-gel dosimeter
    Dvorak, P
    Spevacek, V
    Novotny, J
    Hrbacek, J
    Bogner, J
    Kroupa, B
    Georg, D
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S339 - S340
  • [10] Evaluation of MAGIC-f polymer gel dosimeter for dose profile measurement in small fields and stereotactic irradiation
    Azadeh, Payam
    Amiri, Saeede
    Mostaar, Ahmad
    Joybari, Ali Yaghobi
    Paydar, Reza
    RADIATION PHYSICS AND CHEMISTRY, 2022, 194