COMMISSIONING AND QUALITY ASSURANCE OF TREATMENT PLANNING COMPUTERS

被引:4
|
作者
VANDYK, J
BARNETT, RB
CYGLER, JE
SHRAGGE, PC
机构
[1] LONDON REG CANC CTR, LONDON, ON, CANADA
[2] OTTAWA REG CANC CTR, OTTAWA, ON, CANADA
[3] KINGSTON REG CANC CTR, KINGSTON, ON, CANADA
关键词
TREATMENT PLANNING COMPUTERS; QUALITY ASSURANCE; COMMISSIONING; DOSE CALCULATIONS;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The process of radiation therapy is complex and involves many steps. At each step, comprehensive quality assurance procedures are required to ensure the safe and accurate delivery of a prescribed radiation dose. This report deals with a comprehensive commissioning and ongoing quality assurance program specifically for treatment planning computers. Detailed guidelines are provided under the following topics: (a) computer program and system documentation and user training, (b) sources of uncertainties and suggested tolerances, (c) initial system checks, (d) repeated system-checks, (e) quality assurance through manual procedures, and in vivo dosimetry, and (f) some additional considerations including administration and manpower requirements. In the context of commercial computerized treatment planning systems, uncertainty estimates and achievable criteria of acceptability are presented for: (a) external photon beams, (b) electron beams, (c) brachytherapy, and (d) treatment machine setting calculations. Although these criteria of acceptability appear large, they approach the limit achievable with most of today's treatment planning systems. However, developers of new or improved dose calculation algorithms should strive for the goal recommended by the International Commission of Radiation Units and Measurements of 2% in relative dose accuracy in low dose gradients or 2 mm spatial accuracy in regions with high dose gradients. For brachytherapy, the aim should be 3% accuracy in dose at distances of 0.5 cm or more at any point for any radiation source. Details are provided for initial commissioning tests and follow-up reproducibility tests. The final quality assurance for each patient is to perform an independent manual check of at least one point in the dose distributions, as well as the machine setting calculation. As a check of the overall treatment planning process, in vivo dosimetry should be performed on a select number of patients.
引用
收藏
页码:261 / 273
页数:13
相关论文
共 50 条
  • [1] COMMISSIONING AND QUALITY ASSURANCE OF TREATMENT PLANNING COMPUTERS - COMMENTS
    MCSHAN, DL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (02): : 371 - 372
  • [2] Commissioning and quality assurance of a commercial stereotactic treatment-planning system for extracranial IMRT
    Wang, Lu
    Li, Jinsheng
    Paskalev, Kamen
    Hoban, Peter
    Luo, Wei
    Chen, Lili
    McNeeley, Shawn
    Price, Robert
    Ma, Charlie
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (01): : 21 - 34
  • [3] Commissioning and quality assurance for the treatment delivery components of the AccuBoost system
    Iftimia, Ileana
    Talmadge, Mike
    Ladd, Ron
    Halvorsen, Per
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 129 - 143
  • [4] Commissioning and quality assurance-of the Pinnacle3 radiotherapy treatment planning system for external beam photons
    Bedford, JL
    Childs, PJ
    Hansen, VN
    Mosleh-Shirazi, MA
    Verhaegen, F
    Warrington, AP
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (903): : 163 - 176
  • [5] QUALITY ASSURANCE PROCEDURES DURING COMMISSIONING OF A TREATMENT PLANNING SYSTEM AS A TOOL TO ESTABLISH NEW STANDARDS BEFORE MIGRATION
    Bieleda, G.
    Zwierzchowski, G.
    Blasiak, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S563 - S563
  • [6] COMPUTERS, COMPONENTS AND QUALITY ASSURANCE
    GLACKIN, K
    RYKACZEWSKI, CA
    NEAL, B
    HUGHLETT, M
    [J]. TRANSFUSION, 1984, 24 (05) : 437 - 437
  • [7] Quality assurance procedures based on dosimetric, gamma analysis as a fast reliable tool for commissioning brachytherapy treatment planning systems
    Zwierzchowski, Grzegorz
    Bieleda, Grzegorz
    Skowronek, Janusz
    [J]. RADIOLOGY AND ONCOLOGY, 2017, 51 (04) : 469 - 474
  • [8] Simple Commissioning and Quality Assurance of a Gating System
    Morin, O.
    Hsu, A.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Commissioning and quality assurance of Dynamic WaveArc irradiation
    Sato, Sayaka
    Miyabe, Yuki
    Takahashi, Kunio
    Yamada, Masahiro
    Nakamura, Mitsuhiro
    Ishihara, Yoshitomo
    Yokota, Kenji
    Kaneko, Shuji
    Mizowaki, Takashi
    Monzen, Hajime
    Hiraoka, Masahiro
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 73 - 86
  • [10] Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms
    Rivard, Mark J.
    Beaulieu, Luc
    Mourtada, Firas
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2645 - 2658