AMPEROMETRIC DETECTION OF PEROXIDES WITH POLY(ANILINOMETHYLFERROCENE)-MODIFIED ENZYME ELECTRODES

被引:71
|
作者
MULCHANDANI, A [1 ]
WANG, CL [1 ]
WEETALL, HH [1 ]
机构
[1] NIST,DIV BIOTECHNOL,GAITHERSBURG,MD 20899
关键词
D O I
10.1021/ac00097a016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode employing covalently attached horseradish peroxidase to glassy carbon electrode and a ferrocene-modified polyaniline film deposited by the electrochemical polymerization of N-(ferrocenylmethyl)aniline monomer is reported. The electrode responded rapidly to micromolar concentrations of peroxides, in accordance with the following trend: hydrogen peroxide > cumene hydroperoxide > tert-butyl hydroperoxide. The effect of operational parameters, such as methods of enzyme immobilization, operating potential of the working electrode, pH, and effect of molecular oxygen, were explored for optimum analytical performance. The dynamic properties of this enzyme electrode were exploited for the detection in now injection analysis. Applicability of the enzyme electrode for measurement of peroxide in real sample was demonstrated.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 50 条
  • [21] AMPEROMETRIC ENZYME SENSOR FOR GLUCOSE BASED ON GRAPHITE PASTE-MODIFIED ELECTRODES
    PANDEY, PC
    KAYASTHA, AM
    PANDEY, V
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 33 (02) : 139 - 144
  • [22] AMPEROMETRIC ENZYME-MODIFIED ELECTRODES BASED ON TETRATHIAFULVALENE DERIVATIVES FOR THE DETERMINATION OF GLUCOSE
    LEE, HS
    LIU, LF
    HALE, PD
    OKAMOTO, Y
    HETEROATOM CHEMISTRY, 1992, 3 (03) : 303 - 310
  • [23] AMPEROMETRIC ENZYME ELECTRODES .6. ENZYME ELECTRODES FOR SUCROSE AND LACTOSE
    ALBERY, WJ
    KALIA, YN
    MAGNER, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 325 (1-2): : 83 - 93
  • [24] Poly(Thiophene)/Graphene Oxide-Modified Electrodes for Amperometric Glucose Biosensing
    Pilo, Maria, I
    Baluta, Sylwia
    Loria, Anna C.
    Sanna, Gavino
    Spano, Nadia
    NANOMATERIALS, 2022, 12 (16)
  • [25] STRATEGIES FOR THE DEVELOPMENT OF AMPEROMETRIC ENZYME ELECTRODES
    BARTLETT, PN
    WHITAKER, RG
    BIOSENSORS, 1988, 3 (06) : 359 - 379
  • [26] Amperometric multidetection with composite enzyme electrodes
    de Prada, AGV
    Peña, N
    Parrado, C
    Reviejo, AJ
    Pingarrón, JM
    TALANTA, 2004, 62 (05) : 896 - 903
  • [27] AMPEROMETRIC ENZYME SEQUENCE ELECTRODES FOR CHOLESTEROL
    WOLLENBERGER, U
    KUHN, M
    SCHELLER, F
    DEPPMEYER, V
    JANCHEN, M
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1983, 11 (4-6): : 307 - 317
  • [28] Catalytic surfaces for amperometric enzyme electrodes
    Wang, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 181 - ANYL
  • [29] Amperometric detection of phenols using peroxidase-modified graphite electrodes
    Lindgren, A.
    Emneus, J.
    Ruzgas, T.
    Gorton, L.
    Analytica Chimica Acta, 347 (1-2):
  • [30] Amperometric detection of phenols using peroxidase-modified graphite electrodes
    Lindgren, A
    Emneus, J
    Ruzgas, T
    Gorton, L
    MarkoVarga, G
    ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 51 - 62