Amperometric multidetection with composite enzyme electrodes

被引:30
|
作者
de Prada, AGV [1 ]
Peña, N [1 ]
Parrado, C [1 ]
Reviejo, AJ [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
multianalyte detection; composite biosensors; amperometric detection;
D O I
10.1016/j.talanta.2003.10.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of composite biosensors for multianalyte detection strategies is discussed. Graphite-Teflon rigid composite biosensors offer the possibility of coimmobilization of several enzymes by simple physical inclusion in the bulk of the electrode matrix with no covalent linkages. A novel trienzyme graphite-Teflon-glucose oxidase (GOD)-alcohol oxidase (AOD)-peroxidase (HRP)-ferrocene bisosensor yielded amperometric steady-state currents similar to those obtained with graphite-Teflon-GOD-HRP-ferrocene and graphite-Teflon-AOD-HRP-ferrocene electrodes for the same concentration of glucose and ethanol, respectively. The performance of the trienzyme biosensor for multianalyte detection was evaluated with the simultaneous determination of glucose and ethanol after separation by HPLC, in samples of sweet wine. The simultaneous analysis of several analytes in the same sample should imply that, with an adequate dilution, the concentration levels of the analytes can be included within the ranges of linearity of the corresponding calibration plots. The use of two composite biosensors in a parallel configuration, so that different analytes can be simultaneously detected with no need of chromatographic separation, is also discussed. The usefulness of this approach was evaluated by the simultaneous analysis of glucose and ethanol in sweet wine, and of glucose and lactic acid in red wine. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:896 / 903
页数:8
相关论文
共 50 条
  • [1] AMPEROMETRIC ENZYME ELECTRODES
    LENNOX, B
    ALBERY, WJ
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1987, 23 (04) : R8 - R8
  • [2] AMPEROMETRIC ENZYME - ELECTRODES
    MULCHANDANI, A
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 41 - BTEC
  • [3] AMPEROMETRIC ENZYME ELECTRODES
    NANJO, M
    GUILBAULT, GG
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 173 (MAR20): : 75 - 75
  • [4] Amperometric enzyme electrodes
    Calvo, EJ
    Danilowicz, C
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1997, 8 (06) : 563 - 574
  • [5] AMPEROMETRIC ENZYME ELECTRODES
    GREEN, MJ
    HILL, HAO
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1237 - 1243
  • [6] AMPEROMETRIC ENZYME ELECTRODES
    ALBERY, WJ
    BARTLETT, PN
    CASS, AEG
    EISENTHAL, R
    HIGGINS, IJ
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176): : 107 - 119
  • [7] AMPEROMETRIC AND POTENTIOMETRIC ENZYME ELECTRODES
    HO, MH
    WU, TG
    [J]. ISA TRANSACTIONS, 1985, 24 (01) : 61 - 67
  • [8] AMPEROMETRIC ENZYME ELECTRODES .6. ENZYME ELECTRODES FOR SUCROSE AND LACTOSE
    ALBERY, WJ
    KALIA, YN
    MAGNER, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 325 (1-2): : 83 - 93
  • [9] STRATEGIES FOR THE DEVELOPMENT OF AMPEROMETRIC ENZYME ELECTRODES
    BARTLETT, PN
    WHITAKER, RG
    [J]. BIOSENSORS, 1988, 3 (06) : 359 - 379
  • [10] AMPEROMETRIC ENZYME SEQUENCE ELECTRODES FOR CHOLESTEROL
    WOLLENBERGER, U
    KUHN, M
    SCHELLER, F
    DEPPMEYER, V
    JANCHEN, M
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1983, 11 (4-6): : 307 - 317