DUAL ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL CONTENT IN NEWBORNS - VALIDATION OF THE TECHNIQUE

被引:83
|
作者
BRAILLON, PM
SALLE, BL
BRUNET, J
GLORIEUX, FH
DELMAS, PD
MEUNIER, PJ
机构
[1] EDOUARD HERRIOT HOSP,DEPT RHEUMATOL & BONE DIS,F-69437 LYONS 03,FRANCE
[2] EDOUARD HERRIOT HOSP,DEPT NEONATOL,F-69437 LYONS 03,FRANCE
[3] SHRINERS HOSP CRIPPLED CHILDREN,GENET UNIT,MONTREAL,QUEBEC,CANADA
[4] MCGILL UNIV,DEPT PAEDIAT,MONTREAL H3A 2T5,QUEBEC,CANADA
[5] MCGILL UNIV,DEPT SURG,MONTREAL H3A 2T5,QUEBEC,CANADA
关键词
D O I
10.1203/00006450-199207000-00015
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To evaluate the applicability of dual energy x-ray bone absorptiometry in newborns, precision and accuracy of the method was tested for very small quantities of mineral ranging from less than 0.5 g to about 4 g of hydroxyapatite using a Hologic QDR 1000 instrument. For six femurs excised from preterm stillborns, the mean precision for bone mineral content (BMC) and bone mineral density (BMD) was 1.2 and 0.8%, respectively. Accuracy based on ash weight indicated a mean overestimation of about 7%. In vivo, the precision was assessed by measuring lumbar spine BMC and BMD (L1 to L5) two or three times in 10 newborns (gestational age, 33 to 40 wk). The mean coefficients of variation were 2.40 and 1.55% for BMC and BMD, respectively. Lumbar spine BMC and BMD were also measured once in 30 full-term infants. Values ranged from 1.17 to 3.90 g for BMC and from 0.192 to 0.356 g/cm2 for BMD. The present study shows that dual energy x-ray absorptiometry provides a valuable new tool for the assessment and management of BMC in low birth weight infants and neonates in general.
引用
收藏
页码:77 / 80
页数:4
相关论文
共 50 条
  • [21] BONE-MINERAL DENSITY MEASURED BY DUAL PHOTON AND DUAL ENERGY X-RAY ABSORPTIOMETRY - A PROBLEM OF ACCURACY
    ROZENBERG, S
    PERETZ, A
    PRAET, JP
    VANDROMME, J
    HAM, H
    NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (03) : 189 - 191
  • [22] BONE-MINERAL DENSITY MEASURED BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NORMAL MEN
    KROGER, H
    LAITINEN, K
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1992, 22 (07) : 454 - 460
  • [23] DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR MEASURING TOTAL BONE-MINERAL CONTENT IN THE RAT - STUDY OF ACCURACY AND PRECISION
    CASEZ, JP
    MUEHLBAUER, RC
    LIPPUNER, K
    KELLY, T
    FLEISCH, H
    JAEGER, P
    BONE AND MINERAL, 1994, 26 (01): : 61 - 68
  • [24] PRECISION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY IN DETERMINING BONE-MINERAL DENSITY AND CONTENT OF VARIOUS SKELETAL SITES
    SIEVANEN, H
    OJA, P
    VUORI, I
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (06) : 1137 - 1142
  • [25] ACCURACY AND PRECISION OF LUMBAR BONE-MINERAL CONTENT BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IN LIVE FEMALE MONKEYS
    JAYO, MJ
    RANKIN, SE
    WEAVER, DS
    CARLSON, CS
    CLARKSON, TB
    CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (06) : 438 - 440
  • [26] PRECISION AND ACCURACY OF IN-VIVO BONE-MINERAL MEASUREMENT IN RATS USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    ROZENBERG, S
    VANDROMME, J
    NEVE, J
    AGUILERA, A
    MUREGANCURO, A
    PERETZ, A
    KINTHAERT, J
    HAM, H
    OSTEOPOROSIS INTERNATIONAL, 1995, 5 (01) : 47 - 53
  • [27] SEQUENTIAL AND PRECISE INVIVO MEASUREMENT OF BONE-MINERAL DENSITY IN RATS USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    AMMANN, P
    RIZZOLI, R
    SLOSMAN, D
    BONJOUR, JP
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 (03) : 311 - 316
  • [28] Dual-energy X-ray absorptiometry measurement of bone-mineral density in the distal aspect of the limbs in racing Greyhounds
    Emmerson, TD
    Lawes, TJ
    Goodship, AE
    Rueux-Mason, C
    Muir, P
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2000, 61 (10) : 1214 - 1219
  • [29] MEASUREMENT OF HAND BONE-MINERAL CONTENT BY DUAL ENERGY X-RAY ABSORPTIOMETRY - DEVELOPMENT OF THE METHOD IN NORMALS AND ITS APPLICATION IN RHEUMATOID-ARTHRITIS
    DEODHAR, AA
    SIMPSON, JB
    AKHTAR, N
    WOOLF, AD
    BRITISH JOURNAL OF RHEUMATOLOGY, 1992, 31 : 68 - 68
  • [30] REGIONAL VARIATIONS IN BONE-MINERAL DENSITY AS ASSESSED WITH DUAL-ENERGY PHOTON-ABSORPTIOMETRY AND DUAL X-RAY ABSORPTIOMETRY
    FEYERABEND, AJ
    LEAR, JL
    RADIOLOGY, 1993, 186 (02) : 467 - 469