PRECISION AND ACCURACY OF IN-VIVO BONE-MINERAL MEASUREMENT IN RATS USING DUAL-ENERGY X-RAY ABSORPTIOMETRY

被引:43
|
作者
ROZENBERG, S
VANDROMME, J
NEVE, J
AGUILERA, A
MUREGANCURO, A
PERETZ, A
KINTHAERT, J
HAM, H
机构
[1] Interdisciplinary Group on Osteoporosis, Free Universities of Brussels, Hôpital Saint-Pierre, Brussels, B-1000
关键词
ACCURACY; BONE MINERAL CONTENT; DXA; OSTEOPOROSIS; PRECISION;
D O I
10.1007/BF01623658
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the precision and accuracy of dual-energy X-ray absorptiometry (DXA) for measuring bone mineral content at different sites of the skeleton in rats. In vitro the reproducibility error was very small (< 1%), but in vivo the intra-observer variability ranged from 0.9% to 6.0%. Several factors have been shown to affect in vivo reproducibility: the reproducibility was better when the results were expressed as bone mineral density (BMD) rather than bone mineral content (BMC), intra-observer variability was better than the inter-observer variability, and a higher error was observed for the tibia compared with that for vertebrae and femur. The accuracy of measurement at the femur and tibia was assessed by comparing the values with ash weight and with biochemically determined calcium content. The correlation coefficients (R) between the in vitro BMC and the dry weight or the calcium content were higher than 0.99 for both the femur and the tibia. SEE ranged between 0.0 g (ash weight) and 2.0 mg (Ca content). Using in vitro BMC, ash weight could be estimated with an accuracy error close to 0 and calcium content with an error ranging between 0.82% and 6.80%. The R values obtained between the in vivo and in vitro BMC were 0.98 and 0.97 respectively for femur and tibia, with SEE of 0.04 and 0.02 g respectively. In conclusion, the in vivo precision of the technique was found to be too low. To be of practical use it is important in the design of experimentation to try to reduce the measurement error. This can be achieved by performing measurements in the same position, by repeating measurements several times and by using the mean values of several BMD calculations performed by the same observer on each BMD measurement. Furthermore, better reproducibility can be obtained on the vertebra or the femur than on the tibia.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [1] PRECISION AND ACCURACY FOR RAT BONE-MINERAL MEASUREMENT WITH DUAL X-RAY ABSORPTIOMETRY
    HAGIWARA, S
    LANE, N
    SEBASTIAN, A
    GENANT, H
    KIMMEL, DB
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 : S281 - S281
  • [2] Accuracy and precision of in vivo bone mineral measurements in sheep using dual-energy X-ray absorptiometry
    Pouilles, JM
    Collard, P
    Tremollieres, F
    Frayssinet, P
    Railhac, JJ
    Cahuzac, JP
    Autefage, A
    Ribot, C
    CALCIFIED TISSUE INTERNATIONAL, 2000, 66 (01) : 70 - 73
  • [3] Accuracy and Precision of In Vivo Bone Mineral Measurements in Sheep Using Dual-Energy X-ray Absorptiometry
    J. M. Pouilles
    P. Collard
    F. Tremollieres
    P. Frayssinet
    J. J. Railhac
    J. P. Cahuzac
    A. Autefage
    C. Ribot
    Calcified Tissue International, 2000, 66 : 70 - 73
  • [4] AN EVALUATION OF FOREARM BONE-MINERAL MEASUREMENT WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    LARCOS, G
    WAHNER, HW
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (11) : 2101 - 2106
  • [5] Precision and accuracy of in vivo bone mineral measurements of mice using dual-energy X-ray absorptiometry.
    Nagy, TR
    Wharton, D
    Blaylock, M
    Powell, S
    FASEB JOURNAL, 1999, 13 (05): : A912 - A912
  • [6] SEQUENTIAL AND PRECISE INVIVO MEASUREMENT OF BONE-MINERAL DENSITY IN RATS USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    AMMANN, P
    RIZZOLI, R
    SLOSMAN, D
    BONJOUR, JP
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 (03) : 311 - 316
  • [7] DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR MEASURING TOTAL BONE-MINERAL CONTENT IN THE RAT - STUDY OF ACCURACY AND PRECISION
    CASEZ, JP
    MUEHLBAUER, RC
    LIPPUNER, K
    KELLY, T
    FLEISCH, H
    JAEGER, P
    BONE AND MINERAL, 1994, 26 (01): : 61 - 68
  • [8] ACCURACY AND PRECISION OF LUMBAR BONE-MINERAL CONTENT BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IN LIVE FEMALE MONKEYS
    JAYO, MJ
    RANKIN, SE
    WEAVER, DS
    CARLSON, CS
    CLARKSON, TB
    CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (06) : 438 - 440
  • [9] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE RAT - ACCURACY, PRECISION, AND MEASUREMENT OF BONE LOSS
    GRIFFIN, MG
    KIMBLE, R
    HOPFER, W
    PACIFICI, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 (07) : 795 - 800
  • [10] Precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry
    P. Tothill
    W. J. Hannan
    Osteoporosis International, 2007, 18 : 1515 - 1523