PRECISION AND ACCURACY OF IN-VIVO BONE-MINERAL MEASUREMENT IN RATS USING DUAL-ENERGY X-RAY ABSORPTIOMETRY

被引:43
|
作者
ROZENBERG, S
VANDROMME, J
NEVE, J
AGUILERA, A
MUREGANCURO, A
PERETZ, A
KINTHAERT, J
HAM, H
机构
[1] Interdisciplinary Group on Osteoporosis, Free Universities of Brussels, Hôpital Saint-Pierre, Brussels, B-1000
关键词
ACCURACY; BONE MINERAL CONTENT; DXA; OSTEOPOROSIS; PRECISION;
D O I
10.1007/BF01623658
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the precision and accuracy of dual-energy X-ray absorptiometry (DXA) for measuring bone mineral content at different sites of the skeleton in rats. In vitro the reproducibility error was very small (< 1%), but in vivo the intra-observer variability ranged from 0.9% to 6.0%. Several factors have been shown to affect in vivo reproducibility: the reproducibility was better when the results were expressed as bone mineral density (BMD) rather than bone mineral content (BMC), intra-observer variability was better than the inter-observer variability, and a higher error was observed for the tibia compared with that for vertebrae and femur. The accuracy of measurement at the femur and tibia was assessed by comparing the values with ash weight and with biochemically determined calcium content. The correlation coefficients (R) between the in vitro BMC and the dry weight or the calcium content were higher than 0.99 for both the femur and the tibia. SEE ranged between 0.0 g (ash weight) and 2.0 mg (Ca content). Using in vitro BMC, ash weight could be estimated with an accuracy error close to 0 and calcium content with an error ranging between 0.82% and 6.80%. The R values obtained between the in vivo and in vitro BMC were 0.98 and 0.97 respectively for femur and tibia, with SEE of 0.04 and 0.02 g respectively. In conclusion, the in vivo precision of the technique was found to be too low. To be of practical use it is important in the design of experimentation to try to reduce the measurement error. This can be achieved by performing measurements in the same position, by repeating measurements several times and by using the mean values of several BMD calculations performed by the same observer on each BMD measurement. Furthermore, better reproducibility can be obtained on the vertebra or the femur than on the tibia.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [41] Comment on Tothill and Hannan: precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry
    G. Phillipov
    C. J. Seaborn
    Osteoporosis International, 2008, 19 : 1099 - 1100
  • [42] Does the Precision of Dual-Energy X-ray Absorptiometry for Bone Mineral Density Differ by Sex?
    Krueger, Diane
    Vallarta-Ast, Nellie
    Libber, Jessie
    Gangnon, Ronald
    Binkley, Neil
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (04) : 505 - 509
  • [43] Comment on Tothill and Hannan: precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry
    Phillipov, G.
    Seaborn, C. J.
    OSTEOPOROSIS INTERNATIONAL, 2008, 19 (07) : 1099 - 1100
  • [44] Dual-energy X-ray absorptiometry underestimates in vivo lumbar spine bone mineral density in overweight rats
    Cherif, Rim
    Vico, Laurence
    Laroche, Norbert
    Sakly, Mohsen
    Attia, Nebil
    Lavet, Cedric
    JOURNAL OF BONE AND MINERAL METABOLISM, 2018, 36 (01) : 31 - 39
  • [45] In vivo differences among scan modes in bone mineral density measurement at dual-energy X-ray absorptiometry
    Michele Bandirali
    Luca M. Sconfienza
    Alberto Aliprandi
    Giovanni Di Leo
    Daniele Marchelli
    Fabio M. Ulivieri
    Francesco Sardanelli
    La radiologia medica, 2014, 119 : 257 - 260
  • [46] Is Bone Mineral Density Measurement Using Dual-Energy X-Ray Absorptiometry Affected by Gamma Rays?
    Xie, Liang-Jun
    Li, Jian-Fang
    Zeng, Feng-Wei
    Jiang, Hang
    Cheng, Mu-Hua
    Chen, Yi
    JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (03) : 275 - 278
  • [47] THE BONE-MINERAL DENSITY CHANGE WITH AGING OF JAPANESE WOMEN MEASURED BY SINGLE-ENERGY X-RAY ABSORPTIOMETRY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY
    HOSHI, K
    YAMADA, H
    TSUKIKAWA, S
    SUGANO, T
    ENDO, C
    SATO, A
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1993, 253 (02) : 65 - 69
  • [48] INFLUENCE OF PATIENTS WEIGHT ON DUAL-PHOTON ABSORPTIOMETRY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS OF BONE-MINERAL DENSITY
    MARTIN, P
    VERHAS, M
    ALS, C
    GEERTS, L
    PATERNOT, J
    BERGMANN, P
    OSTEOPOROSIS INTERNATIONAL, 1993, 3 (04) : 198 - 203
  • [49] Dual-energy X-ray absorptiometry registers bone mineral in the liver
    Koufakis, M
    Söderborg, B
    Kallner, G
    Magi, A
    Svensson, U
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2001, 13 (05) : 523 - 528
  • [50] DUAL ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL CONTENT IN NEWBORNS - VALIDATION OF THE TECHNIQUE
    BRAILLON, PM
    SALLE, BL
    BRUNET, J
    GLORIEUX, FH
    DELMAS, PD
    MEUNIER, PJ
    PEDIATRIC RESEARCH, 1992, 32 (01) : 77 - 80