DYNAMIC FIELD SHAPING FOR STEREOTAXIC RADIOSURGERY - A MODELING STUDY

被引:62
|
作者
NEDZI, LA
KOOY, HM
ALEXANDER, E
SVENSSON, GK
LOEFFLER, JS
机构
[1] HARVARD UNIV,CHILDRENS HOSP,SCH MED,BOSTON,MA 02115
[2] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,STEREOTACT RADIOSURG PROGRAM,BOSTON,MA 02115
关键词
STEREOTAXIC RADIOSURGERY; MULTI-LEAF COLLIMATOR; CONFORMAL THERAPY; TREATMENT PLANNING;
D O I
10.1016/0360-3016(93)90316-N
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This work assesses the relative field shaping advantages of dynamic field shaping devices for stereotactic radiosurgery using a linear accelerator. Methods and Materials: We selected 43 intracranial tumors (2.0-4.2 cm maximum dimension, 1.5-25.5 cc tumor volume) out of the first 64 intracranial tumors treated with radiosurgery at the Joint Center for Radiation Therapy. We modeled five field shaping devices, each including a fixed auxilliary circular collimator: (a) fixed circular collimator alone; (b) two independent parallel jaws; (c) four independent rectangular jaws; (d) four independent rotatable jaws; and (e) ''ideal'' multileaf collimator. We adjusted the model parameters until the minimum target isodose was 80% of the dose delivered to isocenter. We defined the treatment volume ratio as the target volume divided by the treatment volume (volume receiving at least the minimum target dose). We used the treatment volume ratio to compare the five models and the actual patient treatments. Results: For 34 tumors originally treated with one isocenter, the median Treatment Volume Ratio was higher for all of the device models except the fixed circular collimator compared to the actual patient treatments. For the nine tumors originally treated with multiple isocenters, the median Treatment Volume Ratio for the actual multiple isocenter treatments was similar to that for two parallel jaws, four rectangular jaws and four rotatable jaws. Only the median ''ideal'' collimator treatment volume ratio was higher for these nine tumors. Conclusion: Simple field shaping devices have approximately 50% of the conformal advantage of an ''ideal'' multileaf collimator. Approximately 50% of typical radiosurgical tumors between 2 and 4 cm have field shaping advantages which exceed the geometrical uncertainties inherent in linear accelerator radiosurgery treatments. The three models, two parallel, four rectangular, or four rotatable independent jaws would improve current linear accelerator technology by providing homogeneous doses with equivalent field shaping for most tumors originally treated with inhomogeneous multiple isocenter plans (6/9 tumors in the current series).
引用
收藏
页码:859 / 869
页数:11
相关论文
共 50 条
  • [31] MOTION PLANNING IN STEREOTAXIC RADIOSURGERY
    SCHWEIKARD, A
    ADLER, JR
    LATOMBE, JC
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1993, 9 (06): : 764 - 774
  • [32] STEREOTAXIC RADIOSURGERY - AT THE THRESHOLD OR AT THE CROSSROADS
    LUNSFORD, LD
    APUZZO, MLJ
    NEUROSURGERY, 1993, 32 (05) : 799 - 804
  • [33] STEREOTAXIC GAMMA-RADIOSURGERY OF CRANIOPHARYNGIOMAS
    KOBAYASHI, T
    TANAKA, T
    KIDA, Y
    PEDIATRIC NEUROSURGERY, 1994, 21 : 69 - 74
  • [34] STEREOTAXIC RADIOSURGERY OF SKULL BASE MENINGIOMAS
    PENDL, G
    SCHROTTNER, O
    FRIEHS, GM
    FEICHTINGER, H
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1995, 64 : 11 - 18
  • [35] STEREOTAXIC RADIOSURGERY - DOES AUSTRALIA NEED IT
    ROSENFELD, JV
    THOMAS, GW
    KAYE, AH
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1990, 60 (07): : 499 - 501
  • [36] STEREOTAXIC RADIOSURGERY FOR RECURRENT MALIGNANT GLIOMAS
    HALL, WA
    DJALILIAN, HR
    SPERDUTO, PW
    CHO, KH
    GERBI, BJ
    GIBBONS, JP
    ROHR, M
    CLARK, HB
    JOURNAL OF CLINICAL ONCOLOGY, 1995, 13 (07) : 1642 - 1648
  • [37] STEREOTAXIC RADIOSURGERY IN THE TREATMENT OF ACOUSTIC TUMORS
    NOREN, G
    ARNDT, J
    HINDMARSH, T
    HIRSCH, A
    ACTA NEUROCHIRURGICA, 1987, 84 (3-4) : 150 - 150
  • [38] RAPID DOSE CALCULATIONS FOR STEREOTAXIC RADIOSURGERY
    BARDASH, M
    AMOLS, HI
    KOHN, S
    MARTEL, MK
    WUU, CS
    SISTI, M
    CHANG, CH
    MEDICAL PHYSICS, 1992, 19 (04) : 965 - 970
  • [39] STEREOTAXIC ANGIOGRAPHY - AN INADEQUATE DATABASE FOR RADIOSURGERY
    BOVA, FJ
    FRIEDMAN, WA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (04): : 891 - 895
  • [40] STEREOTAXIC RADIOSURGERY FOR RECURRENT MALIGNANT GLIOMA
    HALL, WA
    DJALILIAN, HR
    SPERDUTO, PW
    CHO, KH
    GERBI, BJ
    GIBBONS, J
    ROHR, M
    CLARK, HB
    JOURNAL OF NEUROSURGERY, 1995, 82 (02) : A355 - A355