Cerebrospinal Fluid Glucose Measurement at Point-of-Care

被引:0
|
作者
Thomas, Steven
Halstead, Anne Catherine [1 ,2 ,3 ]
Douglas, M. Joanne
Villar, Giselle
Saran, Simrat
Kozak, Elvira
机构
[1] Childrens & Womens Hlth Ctr British Columbia, Dept Pathol, 4480 Oak St, Vancouver, BC V6H 3V4, Canada
[2] Univ British Columbia, Dept Pathol, Vancouver, BC, Canada
[3] Univ British Columbia, Lab Med, Vancouver, BC, Canada
来源
POINT OF CARE | 2012年 / 11卷 / 02期
关键词
cerebrospinal fluid; glucose; point-of-care; spinal anesthesia; failed epidural anesthesia;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The ability to confirm that the fluid obtained during attempted spinal anesthesia after failed epidural anesthesia is cerebrospinal fluid (CSF) would be useful to the obstetric anesthesiologist. This study was designed to determine whether 3 point-of-care glucose devices (Precision Xtra [Abbott Point of Care], StatStrip Glucose Monitor [Nova Biomedical], and ACCU-CHEK Inform II [Roche Diagnostics]) would reliably measure glucose in CSF during routine spinal anesthesia for cesarean section. A sample of CSF was removed after dural puncture, and glucose was tested using all 3 devices at point-of-care. Results were compared with laboratory CSF glucose measurement (Vitros instruments [Ortho Clinical Diagnostics]). Ease of use of the 3 glucose monitors in the operating room setting and the relationship between blood and CSF glucose levels were also examined. Thirty women were studied. With one exception, blood glucose levels were normal. The StatStrip Glucose Monitor and the ACCU-CHEK Inform II gave similar results of CSF glucose as a percentage of blood glucose in most samples. There was no correlation between the length of fast and CSF glucose results. Both the StatStrip Glucose Monitor and the ACCU-CHEK Inform II showed good agreement with laboratory CSF glucose. There was a significant positive bias with the Precision Xtra device. This study confirmed that some point-of-care devices can measure CSF glucose level reliably in the operating room setting. Further studies are needed to see if this will prove useful during attempted spinal anesthesia after failed epidural anesthesia.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [1] Point-of-Care Cerebrospinal Fluid Detection
    Kita, Ashley E.
    Bradbury, Daniel W.
    Taylor, Zachary D.
    Kamei, Daniel T.
    St John, Maie A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 159 (05) : 824 - 829
  • [2] Point-of-care detection of lactate in cerebrospinal fluid
    Stephani, C.
    Choi, A. H. K.
    Moerer, O.
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2021, 9 (01)
  • [3] Point-of-care detection of lactate in cerebrospinal fluid
    C. Stephani
    A. H. K. Choi
    O. Moerer
    Intensive Care Medicine Experimental, 9
  • [4] The accuracy of point-of-care glucose measurement
    O'Kane, Maurice J.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 108 - 109
  • [5] Blood glucose: Measurement in the point-of-care setting
    Kiechle, FL
    Main, RI
    LABORATORY MEDICINE, 2000, 31 (05) : 276 - 282
  • [6] Abdominal Cerebrospinal Fluid Pseudocyst Diagnosed by Point-of-Care Ultrasound
    Ivan, Yaron
    Hauptman, Jason
    Marin, Jennifer R.
    PEDIATRIC EMERGENCY CARE, 2016, 32 (06) : 408 - 409
  • [7] IMPLEMENTATION OF A POINT-OF-CARE QUALITY CONTROL FOR BLOOD GLUCOSE MEASUREMENT
    Finderle, P.
    Prezelj, M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S678 - S678
  • [8] Rapid Point-of-Care Measurement of Cyst Fluid Glucose Is Feasible and Accurate in Predicting Mucinous Pancreatic Cysts
    Zikos, Thomas
    Pham, Kimberly
    Chen, Ann
    Banerjee, Subhas
    Friedland, Shai
    Dua, Monica
    Norton, Jeffrey
    Poultsides, George
    Visser, Brenda
    Park, Walter
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S86 - S86
  • [9] Rapid Diagnostic Test Kit for Point-of-Care Cerebrospinal Fluid Leak Detection
    Bradbury, Daniel W.
    Kita, Ashley E.
    Hirota, Kensuke
    St John, Maie A.
    Kamei, Daniel T.
    SLAS TECHNOLOGY, 2020, 25 (01): : 67 - 74
  • [10] Cerebrospinal fluid/blood glucose point-of-care testing ratio for diagnosing bacterial meningitis in a limited medical resource setting
    Tamune, Hidetaka
    Kuki, Takaie
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2019, 26 (02) : 145 - 145