Rapid Diagnostic Test Kit for Point-of-Care Cerebrospinal Fluid Leak Detection

被引:7
|
作者
Bradbury, Daniel W. [1 ]
Kita, Ashley E. [2 ]
Hirota, Kensuke [1 ]
St John, Maie A. [1 ,2 ,3 ,4 ]
Kamei, Daniel T. [1 ]
机构
[1] Univ Calif Los Angeles, Henry Samueli Sch Engn & Appl Sci, Dept Bioengn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Head & Neck Surg, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Jonsson Comprehens Canc Ctr, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Head & Neck Canc Program, Los Angeles, CA 90095 USA
来源
SLAS TECHNOLOGY | 2020年 / 25卷 / 01期
基金
美国国家卫生研究院;
关键词
cerebrospinal fluid leak; lateral-flow immunoassay; point of care; beta-trace protein; rapid diagnostic test; BETA-TRACE PROTEIN; COMPLICATIONS; OTORRHEA; MARKER; BETA(2)-TRANSFERRIN; TRANSFERRIN; MENINGITIS; RHINORRHEA;
D O I
10.1177/2472630319877377
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cerebrospinal fluid (CSF) leaks can occur when there is communication between the intracranial cavities and the external environment. They are a common and serious complication of numerous procedures in otolaryngology, and if not treated, persistent leaks can increase a patient's risk of developing life-threatening complications such as meningitis. As it is not uncommon for patients to exhibit increased secretions postoperatively, distinguishing normal secretions from those containing CSF can be difficult. Currently, there are no proven, available tests that allow a medical provider concerned about a CSF leak to inexpensively, rapidly, and noninvasively rule out the presence of a leak. The gold standard laboratory-based test requires that a sample be sent to a tertiary site for analysis, where days to weeks may pass before results return. To address this, our group recently developed a semiquantitative, barcode-style lateral-flow immunoassay (LFA) for the quantification of the beta-trace protein, which has been reported to be an indicator of the presence of CSF leaks. In the work presented here, we created a rapid diagnostic test kit composed of our LFA, a collection swab, dilution buffers, disposable pipettes, and instructions. Validation studies demonstrated excellent predictive capabilities of this kit in distinguishing between clinical specimens containing CSF and those that did not. Our diagnostic kit for CSF leak detection can be operated by an untrained user, does not require any external equipment, and can be performed in approximately 20 min, making it well suited for use at the point of care. This kit has the potential to transform patient outcomes.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] Point-of-Care Cerebrospinal Fluid Detection
    Kita, Ashley E.
    Bradbury, Daniel W.
    Taylor, Zachary D.
    Kamei, Daniel T.
    St John, Maie A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 159 (05) : 824 - 829
  • [2] Point-of-care detection of lactate in cerebrospinal fluid
    Stephani, C.
    Choi, A. H. K.
    Moerer, O.
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2021, 9 (01)
  • [3] Point-of-care detection of lactate in cerebrospinal fluid
    C. Stephani
    A. H. K. Choi
    O. Moerer
    Intensive Care Medicine Experimental, 9
  • [4] Diagnostic Value of a SARS-CoV-2 Rapid Test Kit for Detection of Neutralizing Antibodies as a Point-of-Care Surveillance Test
    Chan, Michele Mun Hei
    Leung, Ka-Yi
    Zhang, Ricky Rui Qi
    Liu, Danlei
    Fan, Yujing
    Khong, Matthew Ka Wa
    Tam, Anthony R.
    Chen, Honglin
    Yuen, Kwok-Yung
    Hung, Ivan F. N.
    Chan, Kwok-Hung
    MICROBIOLOGY SPECTRUM, 2022, 10 (02):
  • [5] Evaluation of a point-of-care rapid diagnostic test kit (SICKLECHECK) for screening of sickle cell diseases
    Purohit, Prasanta
    Parida, Chinmayee
    Martha, Tapan Kumar
    Bholo, Snehal
    Naik, Aparupa
    Behera, Samira Kumar
    PLOS ONE, 2024, 19 (08):
  • [6] EVALUATION OF A RAPID POINT-OF-CARE TEST FOR DETECTION OF CRYPTOSPORIDIUM
    Fleece, Molly E.
    Khan, Shaila S.
    Kabir, Mamum
    Haque, Rashidul
    Petri, William A., Jr.
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2015, 93 (04): : 352 - 352
  • [7] A point-of-care test device for MRSA rapid detection
    Zhao, Linlin
    Huang, Xiaochun
    Zhang, Tong
    Zhang, Xinlian
    Jiang, Mengni
    Lu, Huijun
    Sui, Guodong
    Zhao, Yue
    Zhao, Wang
    Liu, Xiao
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 209
  • [8] Diagnosing Dengue at the Point-of-Care: Utility of a Rapid Combined Diagnostic Kit in Singapore
    Gan, Victor C.
    Tan, Li-Kiang
    Lye, David C.
    Pok, Kwoon-Yong
    Mok, Shi-Qi
    Chua, Rachel Choon-Rong
    Leo, Yee-Sin
    Ng, Lee-Ching
    PLOS ONE, 2014, 9 (03):
  • [9] Evaluation of a rapid oral fluid point-of-care test for MDMA
    Wilson, Lisa
    Jehanli, Ahmed
    Hand, Chris
    Cooper, Gail
    Smith, Robert
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (02) : 98 - 104
  • [10] Cerebrospinal Fluid Glucose Measurement at Point-of-Care
    Thomas, Steven
    Halstead, Anne Catherine
    Douglas, M. Joanne
    Villar, Giselle
    Saran, Simrat
    Kozak, Elvira
    POINT OF CARE, 2012, 11 (02): : 73 - 76