Cerebrospinal Fluid Glucose Measurement at Point-of-Care

被引:0
|
作者
Thomas, Steven
Halstead, Anne Catherine [1 ,2 ,3 ]
Douglas, M. Joanne
Villar, Giselle
Saran, Simrat
Kozak, Elvira
机构
[1] Childrens & Womens Hlth Ctr British Columbia, Dept Pathol, 4480 Oak St, Vancouver, BC V6H 3V4, Canada
[2] Univ British Columbia, Dept Pathol, Vancouver, BC, Canada
[3] Univ British Columbia, Lab Med, Vancouver, BC, Canada
来源
POINT OF CARE | 2012年 / 11卷 / 02期
关键词
cerebrospinal fluid; glucose; point-of-care; spinal anesthesia; failed epidural anesthesia;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The ability to confirm that the fluid obtained during attempted spinal anesthesia after failed epidural anesthesia is cerebrospinal fluid (CSF) would be useful to the obstetric anesthesiologist. This study was designed to determine whether 3 point-of-care glucose devices (Precision Xtra [Abbott Point of Care], StatStrip Glucose Monitor [Nova Biomedical], and ACCU-CHEK Inform II [Roche Diagnostics]) would reliably measure glucose in CSF during routine spinal anesthesia for cesarean section. A sample of CSF was removed after dural puncture, and glucose was tested using all 3 devices at point-of-care. Results were compared with laboratory CSF glucose measurement (Vitros instruments [Ortho Clinical Diagnostics]). Ease of use of the 3 glucose monitors in the operating room setting and the relationship between blood and CSF glucose levels were also examined. Thirty women were studied. With one exception, blood glucose levels were normal. The StatStrip Glucose Monitor and the ACCU-CHEK Inform II gave similar results of CSF glucose as a percentage of blood glucose in most samples. There was no correlation between the length of fast and CSF glucose results. Both the StatStrip Glucose Monitor and the ACCU-CHEK Inform II showed good agreement with laboratory CSF glucose. There was a significant positive bias with the Precision Xtra device. This study confirmed that some point-of-care devices can measure CSF glucose level reliably in the operating room setting. Further studies are needed to see if this will prove useful during attempted spinal anesthesia after failed epidural anesthesia.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 50 条
  • [41] Reliability of a point of care testing blood gas analyzer for measurement of lactate levels in cerebrospinal fluid
    Reina, Alberto Fernandez
    Abellan, Maria Dolores Lopez
    Hadri, Samir Attaibi
    Candel, Angela Puche
    Lopez, Maria Isabel Diaz
    Fernandez, Eva Perez
    Morales, Manuel Tomas Orgaz
    de Guadiana-Romualdo, Luis Garcia
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2024, 84 (01): : 76 - 78
  • [42] Comprehensive Assessment of Fluid Status by Point-of-Care Ultrasonography
    Argaiz, Eduardo R.
    Koratala, Abhilash
    Reisinger, Nathaniel
    KIDNEY360, 2021, 2 (08): : 1326 - 1338
  • [43] Sensitivity and specificity of cerebrospinal fluid glucose measurement by an amperometric glucometer
    Alkhalifah, Ahmed S.
    Alqatari, Khalid A.
    Alkhalifa, Abdullah A.
    Akakah, Baneen A.
    Alobaid, Zainab S.
    SAUDI MEDICAL JOURNAL, 2020, 41 (06) : 602 - 606
  • [44] Quantitative Measurement of Deformational Plagiocephaly and Brachycephaly at the Point-of-care
    Seifabadi, Reza
    Aalamifar, Fereshteh
    Hezaveh, S. Hossein
    Kocabalkanli, Can
    Linguraru, Marius George
    MEDICAL IMAGING 2021: COMPUTER-AIDED DIAGNOSIS, 2021, 11597
  • [45] Point-of-care testing applications in the measurement of intestinal inflammation
    Gildner, Theresa E.
    Manthey-Pierce, Courtney C.
    Weaver, Samantha
    Zhang, Angela
    Deleger, Julie
    Cepon-Robins, Tara J.
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2022, 34
  • [46] Measurement of Cardiac Output by Point-of-Care Transthoracic Echocardiography
    Talan, Jordan W.
    Mangalick, Keshav
    Pradhan, Deepak
    Sauthoff, Harald
    ATS SCHOLAR, 2022, 3 (04): : 631 - 633
  • [47] Validation of the Mission Point-of-care device for haemoglobin measurement
    Louw, Susan
    Mayne, Anthony Leland Hamilton
    Wan, Yuen On
    Mayne, Elizabeth
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (01) : E9 - E11
  • [48] Point-of-care glucose measurement systems should be used with great caution in critically ill intensive care unit patients
    Hoedemaekers, Cornelia W.
    Gunnewiek, Jacqueline M. T. Klein
    Van der Hoeven, Johannes G.
    CRITICAL CARE MEDICINE, 2010, 38 (01) : 339 - 339
  • [49] Point-of-Care Glucose Analysis in Neonates Using Modified Quinoprotein Glucose Dehydrogenase
    Dietzen, Dennis J.
    Wilhite, Timothy R.
    Rasmussen, Maynard
    Sheffield, Mark
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (11) : 923 - 928
  • [50] Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass
    Steinfelder-Visscher, J
    Weerwind, PW
    Teerenstra, S
    Brouwer, MHJ
    PERFUSION-UK, 2006, 21 (01): : 33 - 37