AUTOMATIC DETECTION OF THE LEFT-VENTRICULAR MYOCARDIUM LONG AXIS AND CENTER IN TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY

被引:1
|
作者
CAUVIN, JC [1 ]
BOIRE, JY [1 ]
MAUBLANT, JC [1 ]
BONNY, JM [1 ]
ZANCA, M [1 ]
VEYRE, A [1 ]
机构
[1] INSERM,U71,ERIM,CLERMONT FERRAND,FRANCE
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1992年 / 19卷 / 12期
关键词
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; MYOCARDIUM; IMAGE PROCESSING; MATHEMATICAL MORPHOLOGY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method for centering and reorienting automatically the left ventricle in thallium-201 myocardial single photon emission computed tomography (SPET) is proposed. The processing involves the following steps: (a) the transverse sections of the left ventricle are segmented, (b) the three-dimensional skeleton of the left ventricle is extracted using tools of mathematical morphology, (c) the skeleton is fitted to a quadratic surface by the least-squares method, (d) the left ventricle is reoriented and centered using the long axis and the coordinates of the centre of the quadratic surface. A series of 30 consecutive exercise and redistribution Tl-201 SPET studies were centered and reoriented by two operators twice with this method, and twice manually. There was no significant difference in the mean realignment performed by the automatic and the manual methods while centering differed moderately in some instances. In all cases and for all parameters, the reproducibility of the automatic method was 1.00, while it ranged between 0.74 and 0.98 with the manual centering and reorientation. This automatic approach provides a fast and highly reproducible method for the reconstruction of short- and long-axis sections of the left ventricle in Tl-201 SPET.
引用
收藏
页码:1032 / 1037
页数:6
相关论文
共 50 条
  • [41] USEFULNESS OF HYPERVENTILATION TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY FOR THE DIAGNOSIS OF VASOSPASTIC ANGINA
    MASUOKA, T
    AJISAKA, R
    WATANABE, S
    YAMANOUCHI, T
    IIDA, K
    SATO, M
    TAKEDA, T
    TOYAMA, H
    ISHIKAWA, N
    ITAI, Y
    SUGISHITA, Y
    JAPANESE HEART JOURNAL, 1995, 36 (04): : 405 - 420
  • [42] METASTATIC CARDIAC LIPOSARCOMA DIAGNOSED BY TL-201 MYOCARDIAL SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    OSHIMA, M
    KONDO, T
    UNO, Y
    CLINICAL NUCLEAR MEDICINE, 1993, 18 (09) : 801 - 803
  • [43] RESULTS OF ADENOSINE SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY TL-201 IMAGING IN HEMODYNAMIC NONRESPONDERS
    AKSUT, SV
    PANCHOLY, S
    CASSEL, D
    CAVE, V
    HEO, J
    ISKANDRIAN, AS
    AMERICAN HEART JOURNAL, 1995, 130 (01) : 67 - 70
  • [44] TARGET DETECTION USING SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    SIMON, TR
    WALKER, BS
    TRIEBEL, J
    DOWDEY, JE
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 1006 - 1006
  • [45] ESTIMATION OF RIGHT VENTRICULAR PRESSURE IN CHILDREN BY TL-201 MYOCARDIAL IMAGING USING SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    AKIBA, T
    YOSHIKAWA, M
    OTAKI, S
    NAKASATO, M
    SUZUKI, H
    SATO, S
    SATO, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06): : 673 - 676
  • [46] SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY OF THE THYROID
    CHEN, JJS
    LAFRANCE, ND
    ALLO, MD
    COOPER, DS
    LADENSON, PW
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1988, 66 (06): : 1240 - 1246
  • [47] SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN EPILEPSY
    DEVOUS, MD
    LEROY, RF
    HOMAN, RW
    SEMINARS IN NUCLEAR MEDICINE, 1990, 20 (04) : 325 - 341
  • [48] POSITRON EMISSION TOMOGRAPHY DETECTS METABOLIC VIABILITY IN MYOCARDIUM WITH PERSISTENT 24-HOUR SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY TL-201 DEFECTS
    BRUNKEN, RC
    MODY, FV
    HAWKINS, RA
    NIENABER, C
    PHELPS, ME
    SCHELBERT, HR
    CIRCULATION, 1992, 86 (05) : 1357 - 1369
  • [49] SPECT - SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    JASZCZAK, RJ
    COLEMAN, RE
    LIM, CB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (03) : 1137 - 1153
  • [50] SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY OF THE LIVER
    KEYES, JW
    SEMINARS IN LIVER DISEASE, 1989, 9 (01) : 77 - 85