AUTOMATIC DETECTION OF THE LEFT-VENTRICULAR MYOCARDIUM LONG AXIS AND CENTER IN TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY

被引:1
|
作者
CAUVIN, JC [1 ]
BOIRE, JY [1 ]
MAUBLANT, JC [1 ]
BONNY, JM [1 ]
ZANCA, M [1 ]
VEYRE, A [1 ]
机构
[1] INSERM,U71,ERIM,CLERMONT FERRAND,FRANCE
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1992年 / 19卷 / 12期
关键词
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; MYOCARDIUM; IMAGE PROCESSING; MATHEMATICAL MORPHOLOGY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method for centering and reorienting automatically the left ventricle in thallium-201 myocardial single photon emission computed tomography (SPET) is proposed. The processing involves the following steps: (a) the transverse sections of the left ventricle are segmented, (b) the three-dimensional skeleton of the left ventricle is extracted using tools of mathematical morphology, (c) the skeleton is fitted to a quadratic surface by the least-squares method, (d) the left ventricle is reoriented and centered using the long axis and the coordinates of the centre of the quadratic surface. A series of 30 consecutive exercise and redistribution Tl-201 SPET studies were centered and reoriented by two operators twice with this method, and twice manually. There was no significant difference in the mean realignment performed by the automatic and the manual methods while centering differed moderately in some instances. In all cases and for all parameters, the reproducibility of the automatic method was 1.00, while it ranged between 0.74 and 0.98 with the manual centering and reorientation. This automatic approach provides a fast and highly reproducible method for the reconstruction of short- and long-axis sections of the left ventricle in Tl-201 SPET.
引用
收藏
页码:1032 / 1037
页数:6
相关论文
共 50 条
  • [31] DIAGNOSTICS OF DILATED CARDIOMYOPATHY, USING TL-201 SINGLE-PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    HOFFMEISTER, HM
    MULLERSCHAUENBURG, W
    RIESNER, C
    HANKE, H
    KARSCH, KR
    FEINE, U
    SEIPEL, L
    ZEITSCHRIFT FUR KARDIOLOGIE, 1987, 76 : 16 - 16
  • [32] I-123 PHENYLPENTADECANOIC ACID AND SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN IDENTIFYING LEFT-VENTRICULAR REGIONAL METABOLIC ABNORMALITIES IN PATIENTS WITH CORONARY HEART-DISEASE - COMPARISON WITH TL-201 MYOCARDIAL TOMOGRAPHY
    HANSEN, CL
    CORBETT, JR
    PIPPIN, JJ
    JANSEN, DE
    KULKARNI, PV
    UGOLINI, V
    HENDERSON, E
    AKERS, M
    BUJA, LM
    PARKEY, RW
    WILLERSON, JT
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (01) : 78 - 87
  • [33] MEASUREMENT OF INFARCT SIZE AND PERCENTAGE MYOCARDIUM INFARCTED IN A DOG PREPARATION WITH SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY, TL-201, AND IN-111 MONOCLONAL ANTIMYOSIN FAB
    JOHNSON, LL
    LERRICK, KS
    COROMILAS, J
    SELDIN, DW
    ESSER, PD
    ZIMMERMAN, JM
    KELLER, AM
    ALDERSON, PO
    BIGGER, JT
    CANNON, PJ
    CIRCULATION, 1987, 76 (01) : 181 - 190
  • [34] TL-201 SINGLE PHOTON-EMISSION TOMOGRAPHY OF MYOCARDIUM - ADDITIONAL INFORMATION IN REINJECTION STUDIES IS DEPENDENT ON COLLATERAL CIRCULATION
    BARTENSTEIN, P
    SCHOBER, O
    HASFELD, M
    SCHAFERS, M
    MATHEJA, P
    BREITHARDT, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (09): : 790 - 795
  • [35] CLINICAL USEFULNESS OF SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY WITH TL-201 (TI-201-SPECT) IN THE ACUTE PHASE OF MYOCARDIAL-INFARCTION (MI)
    SETSUTA, K
    TOMITA, Y
    TEI, H
    MUNAKATA, K
    HAYAKAWA, H
    KOH, Y
    TANAKA, K
    KATO, T
    TAKANO, T
    SAITOH, R
    OKUYAMA, A
    YAMAGISHI, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1985, 49 (08): : 755 - 755
  • [36] TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH SYMPTOMS OF HEART-DISEASE AND NONSIGNIFICANT CORONARY-ARTERY LESIONS
    SVANE, B
    BONE, D
    ACTA RADIOLOGICA, 1990, 31 (05) : 463 - 468
  • [37] SEQUENTIAL-CHANGES OF INFARCT SIZE FROM ACUTE TO CHRONIC PHASE EVALUATED BY TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    OGATA, I
    KODAMA, M
    YAMADA, A
    NABEYAMA, S
    ASHIHARA, T
    INOU, T
    FUKUYAMA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (08): : 812 - 813
  • [38] SIMULTANEOUS MULTIVESSEL CORONARY-ARTERY SPASM DEMONSTRATED BY QUANTITATIVE-ANALYSIS OF TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    KUGIYAMA, K
    YASUE, H
    OKUMURA, K
    MINODA, K
    TAKAOKA, K
    MATSUYAMA, K
    KOJIMA, A
    KOGA, Y
    TAKAHASHI, M
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (13): : 1009 - 1014
  • [39] TL-201 SINGLE PHOTON-EMISSION COMPUTED TOMOGRAMS OF DOUBLE CANCERS - LUNG AND BREAST
    TONAMI, N
    YOKOYAMA, K
    MICHIGISHI, T
    ABURANO, T
    HISADA, K
    WATANABE, Y
    CLINICAL NUCLEAR MEDICINE, 1989, 14 (08) : 594 - 596
  • [40] QUANTITATIVE DIPYRIDAMOLE TL-201 SINGLE PHOTON-EMISSION TOMOGRAPHY FOR DETECTION OF POST-INFARCT ISCHEMIA
    NIENABER, C
    SPIELMANN, RP
    SALGE, D
    MATHEY, DG
    MONTZ, R
    BLEIFELD, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 66 - 66