AUTOMATIC DETECTION OF THE LEFT-VENTRICULAR MYOCARDIUM LONG AXIS AND CENTER IN TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY

被引:1
|
作者
CAUVIN, JC [1 ]
BOIRE, JY [1 ]
MAUBLANT, JC [1 ]
BONNY, JM [1 ]
ZANCA, M [1 ]
VEYRE, A [1 ]
机构
[1] INSERM,U71,ERIM,CLERMONT FERRAND,FRANCE
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1992年 / 19卷 / 12期
关键词
SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; MYOCARDIUM; IMAGE PROCESSING; MATHEMATICAL MORPHOLOGY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method for centering and reorienting automatically the left ventricle in thallium-201 myocardial single photon emission computed tomography (SPET) is proposed. The processing involves the following steps: (a) the transverse sections of the left ventricle are segmented, (b) the three-dimensional skeleton of the left ventricle is extracted using tools of mathematical morphology, (c) the skeleton is fitted to a quadratic surface by the least-squares method, (d) the left ventricle is reoriented and centered using the long axis and the coordinates of the centre of the quadratic surface. A series of 30 consecutive exercise and redistribution Tl-201 SPET studies were centered and reoriented by two operators twice with this method, and twice manually. There was no significant difference in the mean realignment performed by the automatic and the manual methods while centering differed moderately in some instances. In all cases and for all parameters, the reproducibility of the automatic method was 1.00, while it ranged between 0.74 and 0.98 with the manual centering and reorientation. This automatic approach provides a fast and highly reproducible method for the reconstruction of short- and long-axis sections of the left ventricle in Tl-201 SPET.
引用
收藏
页码:1032 / 1037
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF LEFT-VENTRICULAR MASS BY SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY WITH TL-201
    WOLFE, CL
    CORBETT, JR
    LEWIS, SE
    BUJA, LM
    WILLERSON, JT
    AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (09): : 1365 - 1368
  • [2] TL-201 MYOCARDIAL SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH DILATED CARDIOMYOPATHY
    TAKEZAWA, H
    FUTAGAMI, Y
    MAKINO, K
    YAMAMURO, M
    KONISHI, T
    NAKANO, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (03): : 298 - 299
  • [3] QUANTIFICATION OF REGIONAL MYOCARDIAL PERFUSION BY SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY OF TL-201 UPTAKE
    FINTEL, D
    MCGAUGHEY, M
    FRANK, T
    DIPAULA, A
    BECKER, L
    CLINICAL RESEARCH, 1984, 32 (02): : A164 - A164
  • [4] QUANTITATION OF POSTEXERCISE LUNG TL-201 UPTAKE DURING SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    KAHN, JK
    CARRY, MM
    MCGHIE, I
    PIPPIN, JJ
    AKERS, MS
    CORBETT, JR
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (03) : 288 - 294
  • [5] QUANTIFICATION OF LEG MUSCLE PERFUSION USING TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    OSHIMA, M
    AKANABE, H
    SAKUMA, S
    YANO, T
    NISHIKIMI, N
    SHIONOYA, S
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (04) : 458 - 465
  • [6] TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY IN THE EVALUATION OF SUSPECTED LUNG-CANCER
    TONAMI, N
    SHUKE, N
    YOKOYAMA, K
    SEKI, H
    TAKAYAMA, T
    KINUYA, S
    NAKAJIMA, K
    ABURANO, T
    HISADA, K
    WATANABE, Y
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (06) : 997 - 1004
  • [7] LEFT-VENTRICULAR VOLUMES FROM SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT)
    BUNKER, SR
    SCHMIDT, WP
    HARTSHORNE, MF
    HOWARD, WH
    BAUMAN, JM
    CAWTHON, MA
    KARL, RD
    CIRCULATION, 1984, 70 (04) : 448 - 448
  • [8] DETERMINATION OF LEFT-VENTRICULAR MASS USING SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    WOLFE, CL
    CORBETT, JR
    WILLERSON, JT
    RELLAS, JS
    SOKOLOV, JJ
    BUJA, LM
    LEWIS, SE
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P86 - P86
  • [9] MORPHOLOGICAL ASSESSMENT OF LEFT-VENTRICULAR WALL AND VENTRICULAR ANEURYSM BY TL-201 MYOCARDIAL EMISSION COMPUTED-TOMOGRAPHY
    NAKATA, T
    TANAKA, S
    MURAKAMI, H
    UNO, K
    NOTO, T
    TSUDA, T
    KUBOTA, M
    MORITA, K
    IIMURA, O
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (07): : 589 - 596
  • [10] QUANTITATION OF TL-201 MYOCARDIAL PERFUSION DEFECT SIZE BY SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT)
    CALDWELL, JH
    RITCHIE, JL
    HARP, GD
    WILLIAMS, DL
    STRATTON, JR
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (05) : P29 - P29