THE LADDER PROBE - REVERSE FLOW MEASUREMENTS WITH A HOT-WIRE RAKE

被引:0
|
作者
SOKOLOV, M
GINAT, Z
机构
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A probe consisting of a ladder-like rake of hot wires was developed in order to facilitate velocity measurements in reverse flow situations. Hot-wire signals obtained by the ladder probe capture a substantial section of the instantaneous velocity profile which includes the point where the change of direction occurs. These signals were processed to obtain the thickness of the reverse flow layer through a procedure which detects the point of zero velocity. The procedure was validated through a conservation-type consistency test, frequency response and periodicity tests, and by comparison with results in the literature. Characterization of a turbulent separated layer is discussed. Three different parameters are used to measure the thickness of the reverse flow region: cross streamwise coordinate of the point of zero average velocity, average coordinate of zero velocity points, and the coordinate of the 50% flow direction (forward or reversed) probability point. Relationships between these parameters and physical interpretation of their relevance to the separated flow field are also discussed.
引用
收藏
页码:307 / 318
页数:12
相关论文
共 50 条
  • [31] Compressible flow hot-wire calibration
    Johnston, R
    Fleeter, S
    EXPERIMENTS IN FLUIDS, 1997, 22 (05) : 444 - 446
  • [32] THE HOT-WIRE ANEMOMETER IN SUPERSONIC FLOW
    KOVASZNAY, LSG
    JOURNAL OF THE AERONAUTICAL SCIENCES, 1950, 17 (09): : 565 - &
  • [33] Flow visualizations and hot-wire measurements on air flow in two different neonate incubators
    Yoo, SC
    Kim, YH
    Kwon, CH
    KSME INTERNATIONAL JOURNAL, 2001, 15 (07): : 1051 - 1060
  • [34] Flow visualizations and hot-wire measurements on air flow in two different neonate incubators
    Seoung-Chool Yoo
    Young-Ho Kim
    Chi-Ho Kwon
    KSME International Journal, 2001, 15 : 1051 - 1060
  • [35] A shielded hot-wire probe to detect flow reversals with one-dimensional pulsating flow
    Benjamin, SF
    Liu, Z
    Roberts, CA
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2004, 218 (07) : 797 - 801
  • [36] Errors in hot-wire X-probe measurements induced by unsteady velocity gradients
    Fransson J.H.M.
    Westin K.J.A.
    Experiments in Fluids, 2002, 32 (3) : 413 - 415
  • [37] TRAVERSING ORIFICE HOT-WIRE PROBE PAIR FOR USE IN WALL PRESSURE CORRELATION MEASUREMENTS
    WILLS, JAB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (04): : 447 - &
  • [38] A hot-wire probe for thermal measurements of nanowires and nanotubes inside a transmission electron microscope
    Dames, C.
    Chen, S.
    Harris, C. T.
    Huang, J. Y.
    Ren, Z. F.
    Dresselhaus, M. S.
    Chen, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10):
  • [39] Errors in hot-wire X-probe measurements induced by unsteady velocity gradients
    Fransson, JHM
    Westin, KJA
    EXPERIMENTS IN FLUIDS, 2002, 32 (03) : 413 - 415
  • [40] On near-wall hot-wire measurements
    B. C. Khoo
    Y. T. Chew
    C. J. Teo
    Experiments in Fluids, 2000, 29 : 448 - 460