APPROACHING COMPARABILITY AND RESULTS OF PULSATILE FLOW IN-VITRO TESTING OF PROSTHETIC HEART-VALVES

被引:7
|
作者
BARBARO, V [1 ]
BOCCANERA, G [1 ]
DANIELE, C [1 ]
GRIGIONI, M [1 ]
PALOMBO, A [1 ]
机构
[1] UNIV ROMA LA SAPIENZA,FAC ENGN,DEPT ELECTR,ROME,ITALY
关键词
D O I
10.3109/03091909509012416
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The testing of prosthetic heart values under pulsatile conditions is still a subject for debate among researchers and competent standardization bodies. The laboratory of Biomedical Engineering of the Istituto Superiore di Sanita in Rome, has reproduced the current inter-laboratory situation with several test apparatuses, focusing on the definition of significant measurement parameters and procedures to obtain reasonably comparable data. The laboratory is also equipped with a Laser Doppler Anemometer (LDA) and a High-Speed Cinematographic system (HSC). A 29 mm tilting disc valve model, was mounted in the aortic position. Under tightly controlled system conditions the analyses performed on two pulse duplicators (PDs) may be deemed consistent for the valve model tested. Useful results, an the same value specimen, are reported concerning velocity profiles and turbulent shear stress values (TSS). Furthermore valve motion on the Sheffield PD was monitored during the closing phase, and related cinematic data reported. The applied methodologies can provide relevant data to support surgeon decision making.
引用
收藏
页码:115 / 118
页数:4
相关论文
共 50 条
  • [1] Approaching comparability and results of pulsatile flow in vitro testing of prosthetic heart valves
    Barbaro, V., 1600, Taylor & Francis Ltd, Basingstoke, United Kingdom (19):
  • [2] TESTING OF PROSTHETIC HEART-VALVES
    SWANSON, WM
    CLARK, RE
    MECHANICAL ENGINEERING, 1977, 99 (07) : 101 - 101
  • [3] In-Vitro Pulsatile Flow Testing of Prosthetic Heart Valves: A Round-Robin Study by the ISO Cardiac Valves Working Group
    Changfu Wu
    Neelakantan Saikrishnan
    Aaron J. Chalekian
    Rob Fraser
    Ornella Ieropoli
    Stephen M. Retta
    Russell Joseph
    Shouyan Lee
    Salvador Marquez
    David Mester
    Ning Pan
    Sepehr Vatanpour
    Craig Weinberg
    Ulrich Steinseifer
    Cardiovascular Engineering and Technology, 2019, 10 : 397 - 422
  • [4] In-Vitro Pulsatile Flow Testing of Prosthetic Heart Valves: A Round-Robin Study by the ISO Cardiac Valves Working Group
    Wu, Changfu
    Saikrishnan, Neelakantan
    Chalekian, Aaron J.
    Fraser, Rob
    Ieropoli, Ornella
    Retta, Stephen M.
    Joseph, Russell
    Lee, Shouyan
    Marquez, Salvador
    Mester, David
    Pan, Ning
    Vatanpour, Sepehr
    Weinberg, Craig
    Steinseifer, Ulrich
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2019, 10 (03) : 397 - 422
  • [5] ACCELERATED LIFE TESTING OF PROSTHETIC HEART-VALVES
    FETTEL, BE
    JOHNSTON, DR
    MORRIS, PE
    MEDICAL INSTRUMENTATION, 1980, 14 (03): : 161 - 164
  • [6] ACCELERATED FATIGUE TESTING OF PROSTHETIC HEART-VALVES
    CLARK, RE
    HAGEN, RW
    SIEGFRIED, BA
    SCHIER, JJ
    RUSCHE, JM
    SURGICAL FORUM, 1975, 26 : 242 - 243
  • [7] PROSTHETIC HEART-VALVES
    JAMIESON, WRE
    CURRENT OPINION IN CARDIOLOGY, 1989, 4 (02) : 264 - 268
  • [8] PROSTHETIC HEART-VALVES
    BLACK, MM
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1983, 4 (01): : 98 - 98
  • [9] A METHOD FOR REAL-TIME IN-VITRO OBSERVATION OF CAVITATION ON PROSTHETIC HEART-VALVES
    ZAPANTA, CM
    LISZKA, EG
    LAMSON, TC
    STINEBRING, DR
    DEUTSCH, S
    GESELOWITZ, DB
    TARBELL, JM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (04): : 460 - 468
  • [10] INVESTIGATION OF MICRO-BUBBLES ASSOCIATED WITH PROSTHETIC HEART-VALVES IN AN IN-VITRO MODEL
    MACKAY, TG
    GROSSET, DG
    GEORGIADIS, D
    LEES, KR
    WHEATLEY, DJ
    STROKE, 1994, 25 (03) : 745 - 745