REDUCED VARIABILITY OF INTERPRETATION AND IMPROVED IMAGE QUALITY WITH A TC-99M MYOCARDIAL PERFUSION AGENT - COMPARISON OF TL-201 AND TC-99M-LABELED TETROFOSMIN

被引:37
|
作者
HENDEL, RC
PARKER, MA
WACKERS, FJT
RIGO, P
LAHIRI, A
ZARET, BL
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED,DIV CARDIOVASC MED,NEW HAVEN,CT 06510
[2] STATE UNIV LIEGE,DEPT MED,DIV CARDIOL,B-4000 LIEGE,BELGIUM
[3] NORTHWICK PK HOSP & CLIN RES CTR,DEPT CARDIOL,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
TETROFOSMIN; THALLIUM; MYOCARDIAL PERFUSION IMAGING; RADIOISOTOPE; CORONARY ARTERY DISEASE;
D O I
10.1007/BF02939973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to determine the relative image quality and interobserver variability among four readers for Tl-201 and 99mTc-labeled tetrofosmin myocardial perfusion images. 99mTc-labeled perfusion agents, with near-optimal physical characteristics for gamma camera imaging, may allow for superior image quality and improved consistency of interpretation. However, most studies to date have demonstrated only similarity in the diagnostic accuracy between technetium agents and thallium. Tetrofosmin is a recently developed 99mTc-labeled agent that has shown promising results in early clinical trials. Methods and Results. A multicenter, open-label trial was performed during which treadmill exercise thallium and tetrofosmin scintigraphy was performed within a 2-week period of each other in 216 subjects. Image quality was evaluated subjectively and scans were interpreted in a blinded, independent fashion by four readers. Perfusion abnormalities were graded as consistent with ischemia, infarction, or mixed and were described both globally and regionally. Interobserver variability was assessed by use of the kappa statistic, and receiver-operator curves were compared for each observer for the diagnostic accuracy of each agent. More tetrofosmin images were of excellent quality than with thallium (52% vs 28%; p < 0.05), and when differences in quality were noted between the agents, tetrofosmin was more often superior (p < 0.0001). The interobserver variability was lower with tetrofosmin scintigraphy because generally higher kappa values were noted, especially in the lateral wall. Higher receiver-operator curve areas indicative of improved diagnostic accuracy were noted among the four readers for tetrofosmin in 80% of vascular territories. Conclusions. 99mTc-labeled tetrofosmin scintigraphy yields images of improved quality compared with thallium, and there is an overall improvement in the consistency of image analysis associated with the use of tetrofosmin.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 50 条
  • [41] Visualization of lung cancer with Tc-99(m)-tetrofosmin imaging: A comparison with Tl-201
    Takekawa, H
    Takaoka, K
    Tsukamoto, E
    Kanegae, K
    Kozeki, Y
    Yamaya, A
    Miller, F
    Kawakami, Y
    NUCLEAR MEDICINE COMMUNICATIONS, 1997, 18 (04) : 341 - 345
  • [42] Limitations of parathyroid imaging with Tc-99m/Tl-201 subtraction and early/delayed Tc-99m MIBI imaging
    Schiepers, C
    VanRiet, H
    Mortelmans, L
    DeRoo, M
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (06) : 502 - 503
  • [43] A COMPARISON OF BONE IMAGING WITH TC-99M-LABELED DPD AND TC-99M MDP - CONCISE COMMUNICATION
    BUELL, U
    KLEINHANS, E
    ZORNBOPP, E
    REUSCHEL, W
    MUENZING, W
    MOSER, EA
    SEIDERER, M
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (03) : 214 - 217
  • [44] COMPLEXES OF TC-99M WITH TETRAPEPTIDES, A NEW CLASS OF TC-99M-LABELED AGENTS
    VANBILLOEN, HP
    BORMANS, GM
    DEROO, MJ
    VERBRUGGEN, AM
    NUCLEAR MEDICINE AND BIOLOGY, 1995, 22 (03): : 325 - 338
  • [45] MYOCARDIAL PERFUSION IMAGING AND DYNAMIC ANALYSIS WITH TC-99M TETROFOSMIN
    NAKAJIMA, K
    TAKI, J
    SHUKE, N
    BUNKO, H
    TAKATA, S
    HISADA, K
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (09) : 1478 - 1484
  • [46] Comparison of Tl-201 and nitroglycerin-augmented Tc-99m-tetrofosmin for rest myocardial perfusion scintigraphy by quantitative evaluation
    Moravszki, M.
    Bus, K.
    Buga, K.
    Toth, M.
    Szilvasi, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S242 - S242
  • [47] Comparison of Tc-99m-MIBI, Tc-99m-tetrofosmin, Tc-99m-Q-12 and Tl-201: Biokinetics on tumor-bearing mice.
    Schomacker, K
    Lohr, H
    Scharl, A
    Scheidhauer, K
    Liebenhoff, S
    Salditt, S
    Schicha, H
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1019 - 1019
  • [48] COMPARISON OF TC-99M SESTAMIBI AND TL-201 RETENTION CHARACTERISTICS IN CANINE MYOCARDIUM
    MELON, PG
    BEANLANDS, RS
    DEGRADO, TR
    NGUYEN, N
    PETRY, NA
    SCHWAIGER, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) : 1277 - 1283
  • [49] QUANTITATIVE COMPARISON OF TL-201 WITH TC-99M MIBI (RP-30)
    WATSON, DD
    SMITH, W
    KELLY, TA
    REMBOLD, CM
    TEATS, CD
    BELLER, GA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A27 - A27
  • [50] A comparative evaluation of Tl-201 and Tc-99m sestamibi myocardial perfusion spect imaging in diabetic patients
    Özgür Ömür
    Zehra Özcan
    Murat Argon
    Ebru Tanı Acar
    The International Journal of Cardiovascular Imaging, 2008, 24 : 173 - 181