REDUCED VARIABILITY OF INTERPRETATION AND IMPROVED IMAGE QUALITY WITH A TC-99M MYOCARDIAL PERFUSION AGENT - COMPARISON OF TL-201 AND TC-99M-LABELED TETROFOSMIN

被引:37
|
作者
HENDEL, RC
PARKER, MA
WACKERS, FJT
RIGO, P
LAHIRI, A
ZARET, BL
机构
[1] YALE UNIV,SCH MED,DEPT INTERNAL MED,DIV CARDIOVASC MED,NEW HAVEN,CT 06510
[2] STATE UNIV LIEGE,DEPT MED,DIV CARDIOL,B-4000 LIEGE,BELGIUM
[3] NORTHWICK PK HOSP & CLIN RES CTR,DEPT CARDIOL,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
TETROFOSMIN; THALLIUM; MYOCARDIAL PERFUSION IMAGING; RADIOISOTOPE; CORONARY ARTERY DISEASE;
D O I
10.1007/BF02939973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to determine the relative image quality and interobserver variability among four readers for Tl-201 and 99mTc-labeled tetrofosmin myocardial perfusion images. 99mTc-labeled perfusion agents, with near-optimal physical characteristics for gamma camera imaging, may allow for superior image quality and improved consistency of interpretation. However, most studies to date have demonstrated only similarity in the diagnostic accuracy between technetium agents and thallium. Tetrofosmin is a recently developed 99mTc-labeled agent that has shown promising results in early clinical trials. Methods and Results. A multicenter, open-label trial was performed during which treadmill exercise thallium and tetrofosmin scintigraphy was performed within a 2-week period of each other in 216 subjects. Image quality was evaluated subjectively and scans were interpreted in a blinded, independent fashion by four readers. Perfusion abnormalities were graded as consistent with ischemia, infarction, or mixed and were described both globally and regionally. Interobserver variability was assessed by use of the kappa statistic, and receiver-operator curves were compared for each observer for the diagnostic accuracy of each agent. More tetrofosmin images were of excellent quality than with thallium (52% vs 28%; p < 0.05), and when differences in quality were noted between the agents, tetrofosmin was more often superior (p < 0.0001). The interobserver variability was lower with tetrofosmin scintigraphy because generally higher kappa values were noted, especially in the lateral wall. Higher receiver-operator curve areas indicative of improved diagnostic accuracy were noted among the four readers for tetrofosmin in 80% of vascular territories. Conclusions. 99mTc-labeled tetrofosmin scintigraphy yields images of improved quality compared with thallium, and there is an overall improvement in the consistency of image analysis associated with the use of tetrofosmin.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 50 条
  • [21] A comparison of the repeat rate in myocardial perfusion imaging between Tc-99m sestamibi and Tc-99m tetrofosmin
    Basso, Danny
    Passmore, Gregory
    Zecchin, Thomas
    Butler, Jayme
    Walters, Gordon
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [22] Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT.
    DePuey, EG
    Parmett, S
    Ghesani, M
    Rozanski, A
    Nichols, K
    Salensky, H
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 44 - 44
  • [23] A COMPARISON OF THE TC-99M-LABELED MYOCARDIAL AGENTS DIARS AND DMPE TO TL-201 IN EXPERIMENTAL-ANIMALS
    SULLIVAN, PJ
    WERRE, J
    ELMALEH, DR
    OKADA, RD
    KOPIWODA, SY
    CASTRONOVO, FP
    MCKUSICK, KA
    STRAUSS, HW
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1984, 11 (01): : 3 - &
  • [24] COMPARISON OF TL-201 AND TC-99M SESTAMIBI AT REST FOR MYOCARDIAL VIABILITY ASSESSMENT
    DONDI, M
    TARTAGNI, F
    FANTI, S
    FALLANI, F
    MARENGO, M
    BERGAMINI, C
    CORBELLI, C
    MONETTI, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 663 - 663
  • [25] Tl-201, Tc-99m Sestamibi, and Tc-99m HMDP uptake in multiple brown tumors
    Ohnishi, H
    Abe, M
    Miyagawa, M
    Nishimura, K
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (07) : 601 - 603
  • [26] Effects in the testes after SPECT myocardial perfusion with Tl-201 or Tc-99m HexaMIBI
    Manetou, A
    Limouris, GS
    ANTICANCER RESEARCH, 1997, 17 (3B) : 1841 - 1844
  • [27] COMPARISON OF DIAGNOSTIC-ACCURACY OF DUAL RADIONUCLIDE (TL-201 AND TC-99M ISONITRILE) WITH SAME DAY TC-99M ISONITRILE STRESS TL-201 REST PERFUSION SCINTIGRAPHY
    LUCAS, JR
    AGARWAL, P
    POUNDS, TR
    YU, YZ
    HATTNER, RS
    DAE, MW
    BOTVINICK, EH
    CLINICAL RESEARCH, 1993, 41 (01): : A36 - A36
  • [28] COMPARISON OF DIAGNOSTIC-ACCURACY OF DUAL RADIONUCLIDE (TL-201 AND TC-99M ISONITRILE) WITH SAME DAY TC-99M ISONITRILE STRESS TL-201 REST PERFUSION SCINTIGRAPHY
    LUCAS, JR
    AGARWAL, P
    POUNDS, TR
    ZHU, YY
    HATTNER, RS
    DAE, MW
    CARETTA, RF
    BOTVINICK, EH
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P64 - P64
  • [30] COMPARISON OF SPECT USING TC-99M AGENTS AND TL-201 AND PET FOR THE ASSESSMENT OF MYOCARDIAL PERFUSION AND VIABILITY
    BERMAN, DS
    KIAT, H
    VANTRAIN, KF
    FRIEDMAN, J
    GARCIA, EV
    MADDAHI, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13): : E72 - E79