MEASUREMENT OF ABSORBED DOSE FROM RADIONUCLIDE SOLUTIONS MIXED INTIMATELY WITH THE FBX DOSIMETER

被引:3
|
作者
BENEDETTO, AR
HARRIS, CR
NEFF, RD
机构
[1] UNIV TEXAS, HLTH SCI CTR, DEPT RADIOL, SAN ANTONIO, TX 78284 USA
[2] TEXAS A&M UNIV, DEPT NUCL ENGN, COLLEGE STN, TX 77843 USA
来源
HEALTH PHYSICS | 1985年 / 49卷 / 03期
关键词
D O I
10.1097/00004032-198509000-00008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
引用
收藏
页码:455 / 477
页数:23
相关论文
共 39 条
  • [1] FBX CHEMICAL DOSIMETER FOR MEASUREMENT OF ABSORBED DOSES FROM RADIOPHARMACEUTICALS
    BENEDETTO, AR
    HARRIS, CR
    WAGGENER, RG
    NEFF, RD
    [J]. MEDICAL PHYSICS, 1983, 10 (04) : 549 - 549
  • [2] CORRELATION OF RADIATION ABSORBED DOSE TO THE HUMAN THYROID USING THE FBX DOSIMETER AND EXTERNAL PROBE TECHNIQUES
    BATEMAN, SCL
    [J]. HEALTH PHYSICS, 1985, 49 (01): : 130 - 130
  • [3] Development of a primary standard for absorbed dose from unsealed radionuclide solutions
    Billas, I.
    Shipley, D.
    Galer, S.
    Bass, G.
    Sander, T.
    Fenwick, A.
    Smyth, V.
    [J]. METROLOGIA, 2016, 53 (06) : 1259 - 1271
  • [4] Comment on 'Development of a primary standard for absorbed dose from unsealed radionuclide solutions'
    Ross, C. K.
    [J]. METROLOGIA, 2017, 54 (04) : 610 - 614
  • [5] MEASUREMENT OF BETA-ABSORBED DOSE USING TLD PERSONAL DOSIMETER
    MIYABE, K
    NOMURA, Y
    ISHIGURO, H
    [J]. HEALTH PHYSICS, 1984, 46 (06): : 1327 - 1327
  • [6] Reply to Comment on 'Development of a primary standard for absorbed dose from unsealed radionuclide solutions'
    Billas, I.
    Shipley, D.
    Galer, S.
    Bass, G.
    Sander, T.
    Fenwick, A.
    Duane, S.
    Smyth, V.
    [J]. METROLOGIA, 2017, 54 (04) : 615 - 616
  • [7] STUDY OF THE CLINICAL THERMOLUMINESCENT DOSIMETER IN THE DIRECT MEASUREMENT OF RADIATION ABSORBED DOSE FOR RADIOIMMUNOTHERAPY
    CHIOU, RK
    WESSELS, BW
    WOODSON, M
    LIMAS, C
    [J]. APPLIED RADIATION AND ISOTOPES, 1991, 42 (02) : 181 - &
  • [8] Absorbed Dose Measurement Using Radiophotoluminescent Glass Dosimeter in Therapeutic Proton Beam
    Chang, W.
    Koba, Y.
    Katayose, T.
    Hariu, M.
    Yasui, K.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3502 - 3502
  • [9] From the measurement on the dosimeter to the dose received by the wearer
    Biau, A.
    [J]. RADIOPROTECTION, 2011, 46 (05) : S45 - S47
  • [10] Researching the possibility to use Fricke dosimeter for measurement of absorbed dose generated by pulse electron beam
    Khusnulina, Alena
    [J]. 20TH INTERNATIONAL CONFERENCE FOR STUDENTS AND YOUNG SCIENTISTS: MODERN TECHNIQUES AND TECHNOLOGIES (MTT'2014), 2014, 66