Reply to Comment on 'Development of a primary standard for absorbed dose from unsealed radionuclide solutions'

被引:0
|
作者
Billas, I. [1 ]
Shipley, D. [1 ]
Galer, S. [1 ]
Bass, G. [1 ]
Sander, T. [1 ]
Fenwick, A. [1 ]
Duane, S. [1 ]
Smyth, V. [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
dosimetry; radionuclide solution; extrapolation chamber; primary standard; validation of dose calculation;
D O I
10.1088/1681-7575/aa78ff
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article is a reply to the comment from Ross (2017 Metrologia 54 610) on our paper (Billas et al 2016 Metrologia 53 1259) 'Development of a primary standard for absorbed dose from unsealed radionuclide solutions'.
引用
收藏
页码:615 / 616
页数:2
相关论文
共 50 条
  • [1] Comment on 'Development of a primary standard for absorbed dose from unsealed radionuclide solutions'
    Ross, C. K.
    [J]. METROLOGIA, 2017, 54 (04) : 610 - 614
  • [2] Development of a primary standard for absorbed dose from unsealed radionuclide solutions
    Billas, I.
    Shipley, D.
    Galer, S.
    Bass, G.
    Sander, T.
    Fenwick, A.
    Smyth, V.
    [J]. METROLOGIA, 2016, 53 (06) : 1259 - 1271
  • [3] DEVELOPMENT OF A PRIMARY STANDARD OF ABSORBED DOSE TO WATER FOR PROTON BEAMS
    Cojocaru, Claudiu
    Renaud, James
    Hoehr, Cornelia
    Belanger-Champagne, Camille
    Trinczek, Michael
    McEwen, Malcolm
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S60 - S60
  • [4] MEASUREMENT OF ABSORBED DOSE FROM RADIONUCLIDE SOLUTIONS MIXED INTIMATELY WITH THE FBX DOSIMETER
    BENEDETTO, AR
    HARRIS, CR
    NEFF, RD
    [J]. HEALTH PHYSICS, 1985, 49 (03): : 455 - 477
  • [5] A water calorimeter as a primary standard for absorbed dose in magnetic fields
    De Prez, L.
    De Pooter, J.
    Jansen, B.
    Woodings, S.
    Wolthaus, J.
    Van Asselen, B.
    Van Soest, T.
    Kok, J.
    Raaymakers, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S143 - S144
  • [6] Development of CMOS dosimetry in proton minibeams for enhanced QA and primary standard absorbed dose calorimetry
    Flynn, Samuel
    Allport, Philip
    De Marzi, Ludovic
    Green, Stuart
    Homer, Michael
    Lee, Nigel
    Ortiz, Ramon
    Patriarca, Annalisa
    Prezado, Yolanda
    Thomas, Russell
    Price, Tony
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [7] Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
    de Carlan, Loic
    Baltes, Didier
    Bordy, Jean-Marc
    Daures, Josiane
    Delaunay, Frank
    Ostrowsky, Aime
    Sorel, Soizic
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2009, 14 (11) : 613 - 618
  • [8] Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
    Loïc de Carlan
    Didier Baltès
    Jean-Marc Bordy
    Josiane Daures
    Frank Delaunay
    Aimé Ostrowsky
    Soizic Sorel
    [J]. Accreditation and Quality Assurance, 2009, 14 : 613 - 618
  • [9] CALCULATION OF ABSORBED DOSE FROM RADIOPHARMACEUTICALS - REPLY
    LANE, RG
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1973, 14 (11) : 877 - 878
  • [10] Correction Factors for a Planar Windowless Extrapolation Chamber Measuring Surface Absorbed Dose to Water from An Unsealed Thin-Film Alpha-Emitting Radionuclide
    Khan, A.
    Culberson, W.
    DeWerd, L.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)