THE BIOCOMPATIBILITY OF LOW-TEMPERATURE DIAMOND-LIKE CARBON-FILMS - A TRANSMISSION ELECTRON-MICROSCOPY, SCANNING ELECTRON-MICROSCOPY AND CYTOTOXICITY STUDY

被引:47
|
作者
PARKER, TL [1 ]
PARKER, KL [1 ]
MCCOLL, IR [1 ]
GRANT, DM [1 ]
WOOD, JV [1 ]
机构
[1] UNIV NOTTINGHAM,DEPT MAT ENGN & MAT DESIGN,NOTTINGHAM NG7 2RD,ENGLAND
关键词
D O I
10.1016/0925-9635(94)90104-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Preliminary studies have shown that diamond-like carbon (DLC) coatings can be adherent on a range of substrate materials, resistant to wear and non-toxic to cells in vitro. This has led to the question of the possible biomedical application of DLC-coated materials, particularly in the field of implantation surgery. Assessment of the biocompatibility of implanted material requires two questions to be addressed: (1) is the implanted material toxic to cell growth, and (2) what is the nature of the cell-DLC layer interaction? In this study we show, by the Kenacid Blue cytotoxicity test, that cells grown on DLC-coated PCF membranes exhibit an initial increased attachment to the carbon substrate, and thereafter exhibit a normal growth rate over the 3-day test periods compared with cells grown on uncoated polystyrene. Scanning electron microscopy shows these cells possess characteristics typical of normal cell attachment and growth. Cells were grown on DLC-coated PCF membranes to facilitate examination of the cell-DLC coating interface by transmission electron microscopy. These results show that cells grown on both DLC-coated and non-coated membranes presented normal morphological characteristics of attachment and growth. These findings indicate that the DLC coating is non-toxic in vitro and sustains normal cell growth.
引用
收藏
页码:1120 / 1123
页数:4
相关论文
共 50 条
  • [31] SIMPLE LOW-TEMPERATURE TECHNIQUE FOR SCANNING ELECTRON-MICROSCOPY OF CHEESE
    SCHMIDT, DG
    HENSTRA, S
    THIEL, F
    MIKROSKOPIE, 1979, 35 (1-2) : 50 - 55
  • [32] LOW-TEMPERATURE AND CONVENTIONAL SCANNING ELECTRON-MICROSCOPY OF HUMAN UROTHELIUM
    MIDDLETON, JFS
    MORRIS, JA
    OATES, K
    STAFF, WG
    JOURNAL OF PATHOLOGY, 1983, 139 (04): : 503 - 504
  • [33] LOW-TEMPERATURE SCANNING ELECTRON-MICROSCOPY IN PATHOLOGY OF HUMAN OSTEOARTHROSIS
    LAWTON, DM
    LYONS, TJ
    FAIRCLOUGH, J
    JASANI, K
    MCCLURE, J
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1990, (98): : 779 - 782
  • [34] LOW-TEMPERATURE SCANNING ELECTRON-MICROSCOPY (SEM) OF TISSUE SURFACES
    GARDNER, DL
    OATES, K
    OCONNOR, P
    JOURNAL OF PATHOLOGY, 1980, 131 (03): : 264 - 264
  • [35] THE BALLISTIC PHONON SIGNAL IN LOW-TEMPERATURE SCANNING ELECTRON-MICROSCOPY
    HUEBENER, RP
    METZGER, W
    SCANNING ELECTRON MICROSCOPY, 1985, : 617 - 626
  • [36] NECROTAXIS - SCANNING AND TRANSMISSION ELECTRON-MICROSCOPY STUDY
    VETHAMANY, VG
    VETHAMANY, SK
    BESSIS, M
    NOUVELLE REVUE FRANCAISE D HEMATOLOGIE, 1975, 15 (01): : 83 - 98
  • [37] LOW-TEMPERATURE AND CONVENTIONAL SCANNING ELECTRON-MICROSCOPY OF HUMAN UROTHELIUM
    STAFF, WG
    MIDDLETON, JFS
    MORRIS, JA
    OATES, K
    BRITISH JOURNAL OF UROLOGY, 1985, 57 (01): : 10 - 19
  • [38] ENHANCED FLORAL ANALYSIS BY LOW-TEMPERATURE SCANNING ELECTRON-MICROSCOPY
    BROOKES, B
    SMALL, E
    SCANNING MICROSCOPY, 1988, 2 (01) : 247 - 256
  • [39] ELECTRON-MICROSCOPY OF ISOLATED HUMAN HEPATOCYTES - MICROMETHODS FOR SCANNING AND TRANSMISSION ELECTRON-MICROSCOPY
    TREVISAN, A
    GUDAT, F
    GUGGENHEIM, R
    KREY, G
    LUOND, G
    STALDER, GA
    TONDELLI, P
    BIANCHI, L
    RICERCA IN CLINICA E IN LABORATORIO, 1983, 13 (03): : 307 - 320
  • [40] COMPARATIVE MORPHOLOGY OF THE CHOANOCYTES OF THE SPONGIAE - STUDY USING TRANSMISSION ELECTRON-MICROSCOPY AND SCANNING ELECTRON-MICROSCOPY
    DEVOS, L
    BOURYESNAULT, N
    VACELET, J
    DONADEY, C
    BIOLOGY OF THE CELL, 1981, 41 (01) : A8 - A8