Evaluation of Central Corneal Thickness with Ultrasound Pachymetry After Micro-Coaxial Cataract Surgery

被引:0
|
作者
Ozyol, Erhan [1 ]
Ozyol, Pelin [1 ]
Can, Ertugrul [2 ]
Duman, Rahmi [3 ]
Duman, Resat [3 ]
机构
[1] Unye Devlet Hastanesi, Goz Hastaliklari Klinigi, Ordu, Turkey
[2] Ondokuz Mayis Univ, Goz Hastaliklari Anabilim Dali, Tip Fak, Samsun, Turkey
[3] Onkol Egitim & Arastirma Hastanesi, Goz Hastaliklari Klinigi, Ankara, Turkey
关键词
Phacoemulsification; central corneal thickness; ultrasound pachymetry;
D O I
10.4274/tjo.43.29981
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the changes in central corneal thickness (CCT) in patients with different values before cataract surgery. Material and Method: 90 eyes of 70 patients who had undergone uneventful cataract surgery because of senile cataract were included in this prospective study. The CCT was measured by ultrasound pachymetry. The patients were evaluated in 4 groups according to preoperative CCT values (group 1: 450-500 mu m, group 2: 501-550 mu m, group 3: 551-600 mu m, and group 4: 601-650 mu m). The CCT was measured preoperatively and at 1st, 2nd, 4th, and 8th weeks postoperatively. The chi-square test and one-way analysis of variance test were used for statistical analysis. Results: The increase in CCT was highest in group 1 determined as 71.3 mu m. The increase in group 2 was 43.4, 35.1 in group 3, and 16.6 mu m in group 4. The increase in CCT was significant in all groups at week 1 (p<0.05). The increase in group 1 was statistically significant than in groups 3 and 4 (group 1 and group 3, p=0.025; group 1 and group 4, p<0.01). The increase in group 2 was also statistically significant than in group 4 (p=0.032). The CCT was decreased after the 2nd week. The recovery of CCT to preoperative values was determined at 8th week in group 1, 4th week in groups 2 and 3, and 2nd week in group 4. Discussion: In thin corneas, the increase in central corneal thickness is more prominent and stabilization occurs in a longer time after cataract surgery.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [31] Comparison of Central Corneal Thickness Measurements with Four Different New Devices and Ultrasound Pachymetry
    Simsek, Cem
    Kaya, Cansu
    Karalezli, Aylin
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2022, 52 (05): : 318 - 323
  • [32] AGREEMENT OF CENTRAL CORNEAL THICKNESS with the CASIA SS-1000 ASOCT and ULTRASOUND PACHYMETRY
    Crowell, Eric L.
    Chuang, Alice
    Blieden, Lauren
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [33] Comparison of central corneal thickness measurements using different imaging devices and ultrasound pachymetry
    Can, Ertugrul
    Eser-Ozturk, Hilal
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (04) : 496 - 499
  • [34] Corneal thickness in pigs measured by ultrasound pachymetry in vivo
    Faber, Carsten
    Scherfig, Erik
    Prause, Jan Ulrik
    Sorensen, Knud Erik
    [J]. SCANDINAVIAN JOURNAL OF LABORATORY ANIMAL SCIENCE, 2008, 35 (01) : 39 - 43
  • [35] Comparison of Central Corneal Thickness Measurements between Noncontact Specular Microscopy and Ultrasound Pachymetry
    Ohn, Kyoung
    Lee, Mee Yon
    Lee, Young Chun
    Shin, Hye Young
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (07): : 635 - 642
  • [36] Comparison of central corneal thickness measurements using different imaging devices and ultrasound pachymetry
    Mansoori, Tarannum
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (09)
  • [37] Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry
    Ladi, Jeevan S.
    Shah, Nitant A.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2010, 58 (05) : 385 - 388
  • [38] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754
  • [39] Response of corneal hysteresis and central corneal thickness following clear corneal cataract surgery
    Kandarakis, Artemios
    Soumplis, Vasileios
    Karampelas, Michalis
    Koutroumanos, Ioannis
    Panos, Christos
    Kandarakis, Stylianos
    Karagiannis, Dimitrios
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (06) : 526 - 529
  • [40] Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness
    Miglior, S
    Albe, E
    Guareschi, M
    Mandelli, G
    Gomarasca, S
    Orzalesi, N
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (02) : 174 - 177