FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES

被引:70
|
作者
BIJHOLD, J
VANHERK, M
VIJLBRIEF, R
LEBESQUE, JV
机构
[1] Netherlands Cancer Inst., Amsterdam
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1991年 / 36卷 / 12期
关键词
D O I
10.1088/0031-9155/36/12/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new fast method is presented for the quantification of patient set-up errors during radiotherapy with external photon beams. The set-up errors are described as deviations in relative position and orientation of specified anatomical structures relative to specified field shaping devices. These deviations are determined from parameters of the image transformations that make their features in a portal image align with the corresponding features in a simulator image. Knowledge of some set-up parameters during treatment simulation is required. The method does not require accurate knowledge about the position of the portal imaging device as long as the positions of some of the field shaping devices are verified independently during treatment. By applying this method, deviations in a pelvic phantom set-up can be measured with a precision of 2 mm within 1 minute. Theoretical considerations and experiments have shown that the method is not applicable when there are out-of-plane rotations larger than 2 degrees or translations larger than 1 cm. Interobserver variability proved to be a source of large systematic errors, which could be reduced by offering a precise protocol for the feature alignment.
引用
收藏
页码:1665 / 1679
页数:15
相关论文
共 50 条
  • [31] Evaluation of the Treatment Field Deviations in Different Set-up Positions During Thoracic Radiotherapy in Lung Cancer Patients
    Guzeloz, Zeliha
    Ellidokuz, Hulya
    Yildirim, Ayse
    Yigitbasi, Levent
    Cetingoz, Riza
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (04): : 394 - 402
  • [32] A neural network based method for optical patient set-up registration in breast radiotherapy
    Frosio, I
    Spadea, M
    De Momi, E
    Riboldi, M
    Baroni, G
    Ferrigno, G
    Orecchia, R
    Pedotti, A
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (04) : 677 - 686
  • [33] Extended Analysis of Hypofractionated Radiotherapy Set-up Parameters for Breast Cancer Patients on the FAST Trial
    Thomson, A. H.
    Culley, M.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (03) : 279 - 279
  • [34] An Evaluation of Translational Set-Up Errors to Define An Institutional Protocol for Set-Up Margins in the Treatment of Cancer Cervix Using Image Guided Radiotherapy (IGRT)
    Rani, G.
    Kaur, H.
    Ninan, J.
    Chandrasenan, P.
    Abdussameeh, M. P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [35] EVALUATION OF SET-UP MODIFICATIONS IN RADIOTHERAPY OF HEAD & NECK AFTER A SCHEDULED TREATMENT REPLANNING
    Frascino, V.
    Balducci, M.
    D'Agostino, G. R.
    Mantini, G.
    Mattiucci, G. C.
    Dinapoli, N.
    Gambacorta, M. A.
    Mazzeo, E.
    Bonomo, P.
    Patriccioli, S.
    Valentini, V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S432 - S432
  • [36] Anatomic feature-based registration for patient set-up in head and neck cancer radiotherapy
    Sharp, GC
    Kollipara, S
    Madden, T
    Jiang, SB
    Rosenthal, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19): : 4667 - 4679
  • [37] Cone beam CT evaluation of patient set-up accuracy as a QA tool
    Nielsen, Morten
    Bertelsen, Anders
    Westberg, Jonas
    Jensen, Henrik R.
    Brink, Carsten
    [J]. ACTA ONCOLOGICA, 2009, 48 (02) : 271 - 276
  • [38] Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis
    Pallotta, Stefania
    Vanzi, Eleonora
    Simontacchi, Gabriele
    Marrazzo, Livia
    Ceroti, Marco
    Paiar, Fabiola
    Livi, Lorenzo
    Bucciolini, Marta
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (09) : 726 - 733
  • [39] A quantitative portal imaging assessment of set-up discrepancies during radiation therapy for spinal metastases
    Easton, D
    Vavda, A
    Cops, F
    Goodridge, C
    Leon, G
    Scott, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S562 - S562
  • [40] Set-up uncertainty during breast radiotherapy Image-guided radiotherapy for patients with initial extensive variation
    Yang, D. S.
    Yoon, W. S.
    Chung, S. Y.
    Lee, J. A.
    Lee, S.
    Park, Y. J.
    Kim, C. Y.
    Son, G. S.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (04) : 315 - 320