Cone beam CT evaluation of patient set-up accuracy as a QA tool

被引:21
|
作者
Nielsen, Morten [1 ]
Bertelsen, Anders [1 ]
Westberg, Jonas [1 ]
Jensen, Henrik R. [1 ]
Brink, Carsten [1 ]
机构
[1] Odense Univ Hosp, Radiofys Lab, DK-5000 Odense C, Denmark
关键词
RADIATION-THERAPY; QUALITY-ASSURANCE; RADIOTHERAPY; 3D;
D O I
10.1080/02841860802245155
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. To quantify by means of cone beam CT the random and systematic uncertainty involved in radiotherapy, and to determine if this information can be used for e.g. technical quality assurance, evaluation of patient immobilization and determination of margins for the treatment planning. Patients and methods. Eighty four cancer patients have been cone beam CT scanned at treatment sessions 1, 2, 3, 10 and 20. Translational and rotational errors are analyzed. Results and conclusions. For the first three treatment sessions the mean translational error in the AP direction is 1 mm; this indicates a small error in the calibration of coronal isocentric laser. The observed SD of the systematic error in each direction is 1 mm if a correction is made after the third fraction with an action limit of 4 mm. The SD of the random errors of the patient group is approximately 1 mm in each direction. The rotational errors have a vanishing mean and a systematic error of 0.5-1.2 degrees and a random error of 0.4-0.7 degrees. The uncertainties from the first three treatment sessions (disregarding rotations) lead to a margin of 4 mm from ITV to PTV for Head-and-Neck patients (all directions) and Thorax patients (AP and lateral directions). In the CC direction, the margin has to be 5 mm for the Thorax patients. The total uncertainty on the patient position grows during the treatment course, especially in the CC direction for patients receiving thoracical irradiation. This may stem from problems in the immobilization of these patients. Consequently, it may be necessary to increase the margins in the CC direction. Once the CBCT scans have been made, the information is available for off-line analysis without any extra workload. Thus, the CBCT data can supplement scheduled QA checks.
引用
下载
收藏
页码:271 / 276
页数:6
相关论文
共 50 条
  • [1] A Patient Set-up Protocol Based on Partially Blocked Cone-beam CT
    Zhu, Lei
    Wang, Jing
    Xie, Yaoqin
    Starman, Jared
    Fahrig, Rebecca
    Xing, Lei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (02) : 191 - 198
  • [2] A Patient Set-Up Protocol Based On Partially Blocked Cone-Beam CT
    Zhu, L.
    Wang, J.
    Xie, Y.
    Starman, J.
    Fahrig, R.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Cone-Beam CT for Inter-Fractional Patient Set-Up Verification in Particle Therapy
    Pella, A.
    Fattori, G.
    Riboldi, M.
    Cerveri, P.
    Ricotti, R.
    Tagaste, B.
    Giorgetto, A.
    Ciocca, M.
    Valvo, F.
    Orecchia, R.
    Baroni, G.
    MEDICAL PHYSICS, 2018, 45 (06) : E220 - E220
  • [4] Breast patient set-up verification: Comparison between EPI and cone beam CT matching results
    van Vliet-Vroegindewij, C.
    Heemsbergen, W.
    Minkema, D.
    Betgen, A.
    Rasch, C.
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S280 - S280
  • [5] Evaluation of the cone-beam CT for the determination of the three-dimensional set-up mistake - the new standard
    Guckenberger, M.
    Meyer, J.
    Wilbert, J.
    Baier, K.
    Sauer, O.
    Vordermark, D.
    Flentje, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 2 - 2
  • [6] Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
    Rudat, Volker
    Hammoud, Mohamed
    Pillay, Yogin
    Alaradi, Abdul Aziz
    Mohamed, Adel
    Altuwaijri, Saleh
    RADIATION ONCOLOGY, 2011, 6
  • [7] Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
    Volker Rudat
    Mohamed Hammoud
    Yogin Pillay
    Abdul Aziz Alaradi
    Adel Mohamed
    Saleh Altuwaijri
    Radiation Oncology, 6
  • [8] Uncertainty of megavoltage cone beam CT (MVCBCT) and CT on rails (PRIMATOM) for set-up control.
    Zielinska-Dabrowska, S.
    Kukolowicz, P. F.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S231 - S231
  • [9] A Study on the Availability of the On-Board Imager (OBI) and Cone-Beam CT (CBCT) in the Verification of Patient Set-up
    Bak, Jino
    Park, Sung Ho
    Park, Suk Won
    RADIATION ONCOLOGY JOURNAL, 2008, 26 (02): : 118 - 125
  • [10] CONE-BEAM CT GUIDANCE FOR SET-UP VERIFICATION IN EXTREMITY SOFT TISSUE SARCOMA PATIENTS
    Betgen, A.
    Haas, R.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S183 - S184