FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES

被引:70
|
作者
BIJHOLD, J
VANHERK, M
VIJLBRIEF, R
LEBESQUE, JV
机构
[1] Netherlands Cancer Inst., Amsterdam
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1991年 / 36卷 / 12期
关键词
D O I
10.1088/0031-9155/36/12/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new fast method is presented for the quantification of patient set-up errors during radiotherapy with external photon beams. The set-up errors are described as deviations in relative position and orientation of specified anatomical structures relative to specified field shaping devices. These deviations are determined from parameters of the image transformations that make their features in a portal image align with the corresponding features in a simulator image. Knowledge of some set-up parameters during treatment simulation is required. The method does not require accurate knowledge about the position of the portal imaging device as long as the positions of some of the field shaping devices are verified independently during treatment. By applying this method, deviations in a pelvic phantom set-up can be measured with a precision of 2 mm within 1 minute. Theoretical considerations and experiments have shown that the method is not applicable when there are out-of-plane rotations larger than 2 degrees or translations larger than 1 cm. Interobserver variability proved to be a source of large systematic errors, which could be reduced by offering a precise protocol for the feature alignment.
引用
收藏
页码:1665 / 1679
页数:15
相关论文
共 50 条
  • [1] Registration of electronic portal images for patient set-up verification
    Matsopoulos, GK
    Asvestas, PA
    Delibasis, KK
    Kouloulias, V
    Uzunoglu, N
    Karaiskos, P
    Sandilos, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3279 - 3289
  • [2] IMPACT OF PORTAL IMAGES FREQUENCY ON PATIENTS' SET-UP ERRORS DURING PROSTATE CANCER RADIOTHERAPY
    Korytkowska, J.
    Skorska, M.
    Ryczkowski, A.
    Bak, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S582 - S582
  • [3] Evaluation of set-up errors and determination of set-up margin in pelvic radiotherapy by electronic portal imaging device (EPID)
    Noghreiyan, Vajiheh Vejdani
    Nasseri, Shahrookh
    Anvari, Kazem
    Naji, Maryam
    Momennezhad, Mehdi
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 150 - 156
  • [4] A structure-based method for on-line matching of portal images for an optimal patient set-up in radiotherapy
    Kreuder, F
    Schreiber, B
    Kausch, C
    Dossel, O
    [J]. PHILIPS JOURNAL OF RESEARCH, 1998, 51 (02) : 317 - 337
  • [5] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [6] Evaluation of patient set-up variation in isocentric breast radiotherapy using an electronic portal imaging device (EPID)
    Petillion, S.
    Swinnen, A.
    Van den Heuvel, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S205 - S205
  • [7] Evaluation of set-up errors in head and neck radiotherapy using electronic portal imaging
    Strbac, Bojan
    Jokic, Vesna Spasic
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (05): : 531 - 536
  • [8] Thorax set-up verification with multiple oblique treatment portal images
    Thompson, C. M.
    Hamilton, C. S.
    Vaarkamp, J.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (983): : 950 - 955
  • [9] EVALUATION OF THE EFFECT OF TUMOUR BED MARKER MOVEMENT UPON PATIENT SET-UP ACCURACY DURING BREAST RADIOTHERAPY
    Harris, E.
    Donovan, E.
    Coles, C.
    Eagle, S.
    Kirby, A.
    Evans, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S439 - S439
  • [10] Patient set-up for proton radiotherapy using digital X-ray images of implanted fiducials
    Zygmanski, P
    Rosenthal, S
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 332 - 333