The effectiveness of an active power filter depends basically on three characteristics: a) the modulation method used; b) the design characteristics of the PWM modulator; and c) the method implemented to generate the reference template, For the last characteristic there are many methods, most of them complicated and hence difficult to implement and adjust, In this paper, a new method, which has simplicity at its main characteristic, is presented, The method is based on ''Sample and Hold'' circuits, synchronized with the peak value of the phase-to-neutral mains voltage, This method is useful for shunt active power filters and is capable to eliminate harmonics, compensate power factor, and correct unbalance problems simultaneously. It also has the ability to slow down sudden transient changes in the load. Experimental results, with the reference template obtained with the method, are presented in the paper.
引用
收藏
页码:636 / 641
页数:6
相关论文
共 50 条
  • [41] Reference values for three-phase active power filter
    Stanciu, D.
    Florescu, A.
    Stoichescu, D. A.
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR 2008), THETA 16TH EDITION, VOL III, PROCEEDINGS, 2008, : 200 - 203
  • [42] A High Performance Three-Phase Active Power Filter
    Jiang, Maoh-Chin
    Perng, Shyh-Shing
    Shih, Bing-Jyun
    Liu, Tai-Chun
    Ke, Wei-Cheng
    [J]. 2014 TENTH INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATION HIDING AND MULTIMEDIA SIGNAL PROCESSING (IIH-MSP 2014), 2014, : 848 - 851
  • [43] Computer investigation of three-phase active power filter
    Antchev, MH
    Petkova, MP
    [J]. 27th International Spring Seminar on Electronics Technology, Books 1-3, Conference Proceedings: MEETING THE CHALLENGES OF ELECTRONICS TECHNOLOGY PROGRESS, 2004, : 207 - 213
  • [44] The Effect of Load Power Factor on the Efficiency of Three-Phase Four-Wire Power System with Shunt Active Filter
    Artemenko, M. Yu.
    Batrak, L. M.
    Polishchuk, S. Y.
    Mykhalskyi, V. M.
    Shapoval, I. A.
    [J]. 2016 IEEE 36TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2016, : 277 - 282
  • [45] System and Control Design of a Hybrid Active Power Filter in Three-Phase Four-Wire System
    Lam, Chi-Seng
    Wong, Man-Chung
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS: ELECTRIC VEHICLE AND GREEN ENERGY, 2009, : 92 - 92
  • [46] Design and performance of an active power filter for unbalanced loads
    Gao, DW
    Lu, QC
    Sun, XR
    [J]. POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2496 - 2500
  • [47] Three-Phase Shunt Active Power Filter Control with Line Current Sensing Only, Under Unbalanced Loading Conditions
    Hekimoglu, B.
    Cakir, M.
    Abut, N.
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (04): : 1398 - 1404
  • [48] Power Quality Enhancement for Nonlinear Unbalanced Loads through Improved Active Power Filter Control
    Youssef, Tarek A.
    Elsayed, Ahmed T.
    Berzoy, Alberto
    Mohammed, Osama A.
    [J]. IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 5202 - 5207
  • [49] Adaptive RBF Neural Network Control for Three-Phase Active Power Filter
    Fei, Juntao
    Wang, Zhe
    [J]. INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2013, 10
  • [50] An intelligent control for three-phase and four-wire active power filter
    Jiao, Junsheng
    [J]. ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2013, 80 (05): : 271 - 276