The Effect of Load Power Factor on the Efficiency of Three-Phase Four-Wire Power System with Shunt Active Filter

被引:0
|
作者
Artemenko, M. Yu. [1 ]
Batrak, L. M. [1 ]
Polishchuk, S. Y. [2 ]
Mykhalskyi, V. M. [2 ]
Shapoval, I. A. [2 ]
机构
[1] Natl Tech Univ Ukraine, Kyiv Polytech Inst, Dept Acoust & Acoustoelect, Kiev, Ukraine
[2] Natl Acad Sci Ukraine, Inst Electrodynam, Kiev, Ukraine
关键词
efficiency; power factor; shunt active power filter; INSTANTANEOUS COMPENSATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The formula for determining efficiency of three-phase four-wire power system for unbalanced non-sinusoidal mode with a given load power factor and the known ratio of short circuit power to load active power has been derived. The new formula of the apparent power, which takes into account the power losses of the neutral conductor, has been used in order to determine the power factor. The adequacy of the proposed ratios is shown in the example of calculation of efficiency of three-phase four-wire power system for a simple unbalanced load. Analytical condition for the energy feasibility of a shunt active power filter (SAF) to improve the efficiency of the power system has been derived.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [1] The Study of Three-Phase Four-Wire Shunt Active Power Filter
    Huang, Hai-hong
    Xu, Ruo-bing
    Wang, Hai-xin
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 3496 - 3499
  • [2] Simulation of three-phase four-wire shunt active power filter
    Wang, Ji-Dong
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2007, 40 (SUPPL.): : 95 - 99
  • [3] Simulation of Three-phase Four-wire Shunt Active Power Filter
    Wang, Jidong
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1702 - 1705
  • [4] An efficient control system of shunt active power filter in three-phase four-wire power system
    School of Electricity and Information Engineering, Beijing University of Civil Engineering and Architecture, Beijing, China
    不详
    Int. J. Control Autom., 9 (275-290):
  • [5] Design and Performance of a Shunt Active Power Filter for Three-phase Four-wire System
    Wu, Diyun
    Che, Yanbo
    Cheng, K. W. E.
    2009 3RD INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS: ELECTRIC VEHICLE AND GREEN ENERGY, 2009, : 88 - 88
  • [6] Three-phase Four-wire Shunt Active Power Filter Based on DSP
    Chen, Lezhu
    Jia, Zhoujun
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2, 2010, : 383 - 386
  • [7] Energy control of three-phase four-wire shunt active power filter
    Rodríguez, P
    Pindado, R
    Pou, J
    IECON'03: THE 29TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1 - 3, PROCEEDINGS, 2003, : 1061 - 1066
  • [8] Performance Analysis of Three-phase Four-wire Shunt Active Power Filter
    Vanjani, Harsha
    Choudhury, U. K.
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON RELIABILTY, OPTIMIZATION, & INFORMATION TECHNOLOGY (ICROIT 2014), 2014, : 496 - 500
  • [9] Analysis of possibility to increase the efficiency of three-phase four-wire power system by means of shunt active filter
    Artemenko, M. Yu
    Batrak, L.M.
    Mykhalskyi, V.M.
    Polishchuk, S.Y.
    Technical Electrodynamics, 2015, 2015 (06): : 12 - 18
  • [10] Active power filter used for three-phase four-wire system
    Zhuo, F
    Wang, Y
    Li, H
    Wang, Z
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 616 - 619